Evaluation of Commercial Glucometer Test Strips for Potential Measurement of Glucose in Tears

The DOI matches its Crossref record; 36 of the 37 references it cites were found in a registry or an index.

Abstract

Tear glucose measurements have been suggested as a potential alternative to blood glucose monitoring for diabetic patients. While previous work has reported that there is a correlation between blood and tear glucose levels in humans, this link has not been thoroughly established and additional clinical studies are needed. Herein, we evaluate the potential of using commercial blood glucose test strips to measure glucose in tears. Of several blood glucose strips evaluated, only one brand exhibits the low detection limit required for quantitating glucose in tears. Calibration of these strips in the range of 0-100 μM glucose with an applied potential of 150 mV to the working electrode yields a sensitivity of 0.127 nA/μM and a limit of quantitation (LOQ) of 9 μM. The strips also exhibit ≤13% error (n = 3) for 25, 50, and 75 μM glucose in the presence of 10 μM acetaminophen, 100 μM ascorbic acid, and 100 μM uric acid. Measurements of glucose in tears from nine normal (nondiabetic) fasting human subjects using strips yielded glucose values within the range of 5-148 μM (mean = 47 μM, median = 43 μM), similar to those for human tears reported by others with more complex LC-MS methods. The glucometer strip method could facilitate more clinical studies to determine whether tear glucose and blood glucose levels sufficiently correlate for application to routine measurements in tears to supplement blood glucose testing. This would be especially helpful for children, adolescents, other Type 1 diabetics, and also for Type 2 diabetics who require treatment with insulin and cannot tolerate multiple finger sticks per day.

Overview

Integrity signals

Registry

Crossref · 10.1021/ac4040168

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 36 references

Research works printed but not linked: 2

  1. Choy C. K. M., 2000, Invest. Ophthalmol. Vis. Sci., 41, 3293
  2. Kalisz H. M, 2000, Biochem. J., 349, 553

Cited by

See all 69

Metadata

Authors
Cha, K. H., Jensen, G. C., Balijepalli, A. S., Cohan, B. E., & Meyerhoff, M. E.
Affiliations
  • University of Michigan (US)
  • EyeLab Group LLC, 2350 Washtenaw Avenue No. 4, Ann Arbor, Michigan, 48104-4525, United States
Corresponding author
Meyerhoff, Mark E.
Venue
Analytical Chemistry
Published
2014-01-24
Volume
86
Issue
3
Pages
1902-1908
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2094203185
Cited by
67
References
37
Citations by year
2026: 5 · 2025: 1 · 2024: 6 · 2023: 6 · 2022: 5 · 2021: 8 · 2020: 7 · 2019: 5 · 2018: 4 · 2017: 2 · 2016: 10 · 2015: 6 · 2014: 2
FWCI
3.54
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
Keywords
tear glucose, blood glucose monitoring, diabetes mellitus, non-invasive glucose measurement, limit of quantification, acetaminophen interference, ascorbic acid interference, uric acid interference
MeSH terms
Electrochemistry, Glucose, Humans, Reagent Strips, Tears, Blood Glucose Self-Monitoring, Limit of Detection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Commercial Glucometer Test Strips for Potential Measurement of Glucose in Tears. https://app.cochat.ai/papers/10.1021/ac4040168
The paper
Cha, K. H., Jensen, G. C., Balijepalli, A. S., Cohan, B. E., & Meyerhoff, M. E. (2014). Evaluation of Commercial Glucometer Test Strips for Potential Measurement of Glucose in Tears. Analytical Chemistry. https://doi.org/10.1021/ac4040168

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.