The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Observational Study of Peripheral Intravenous Catheter Outcomes in Adult Hospitalized Patients: A Multivariable Analysis of Peripheral Intravenous Catheter Failure
Open accessAbstract
BACKGROUND: Almost 70% of hospitalized patients require a peripheral intravenous catheter (PIV), yet up to 69% of PIVs fail prior to completion of therapy. OBJECTIVE: To identify risk factors associated with PIV failure. DESIGN: A single center, prospective, cohort study. SETTING: Medical and surgical wards of a tertiary hospital located in Queensland, Australia. PARTICIPANTS: Adult patients requiring a PIV. MEASUREMENTS: Demographic, clinical, and potential PIV risk factors were collected. Failure occurred if the catheter had complications at removal. RESULTS: We recruited 1000 patients. Catheter failure occurred in 512 (32%) of 1578 PIVs. Occlusion/infiltration risk factors included intravenous (IV) flucloxacillin (hazard ratio [HR], 1.98; 95% confidence interval [CI], 1.19‐3.31), 22‐gauge PIVs (HR, 1.43; 95% CI, 1.02‐2.00), and female patients (HR, 1.48; 95% CI, 1.10‐2.00). Phlebitis was associated with female patients (HR, 1.81; 95% CI, 1.40‐2.35), bruised insertion sites (HR, 2.16; 95% CI, 1.26‐3.71), IV flucloxacillin (HR, 2.01; 95% CI, 1.26‐3.21), and dominant side insertion (HR, 1.39; 95% CI, 1.09‐1.77). Dislodgement risks were a paramedic insertion (HR, 1.78; 95% CI, 1.03‐3.06). Each increase by 1 in the average number of daily PIV accesses was associated (HR 1.11, 95% CI 1.03‐1.20)–(HR 1.14, 95% CI 1.08‐1.21) with occlusion/infiltration, phlebitis and dislodgement. Additional securement products were associated with less (HR 0.32, 95% CI 0.22‐0.46)–(HR 0.63, 95% CI 0.48‐0.82) occlusion/infiltration, phlebitis and dislodgement. CONCLUSION: Modifiable risk factors should inform education and inserter skill development to reduce the currently high rate of PIV failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Harris, P. A., Taylor, R., Thielke, R., Payne, J., Gonzalez, N., & Conde, J. G. (2009) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2008.08.010 · Cited by 51,384
Relaxing the Rule of Ten Events per Variable in Logistic and Cox Regression
Vittinghoff, E., & McCulloch, C. E. (2007) · American Journal of Epidemiology · doi:10.1093/aje/kwk052 · Cited by 4,359
The validity and practicality of sun-reactive skin types I through VI
Fitzpatrick, T. B. (1988) · Archives of Dermatology · doi:10.1001/archderm.1988.01670060015008 · Cited by 4,339
Chopra, V., Flanders, S. A., Saint, S., Woller, S. C., O'Grady, N. P., Safdar, N., Trerotola, S. O., Saran, R., Moureau, N., Wiseman, S., et al. (2015) · Annals of Internal Medicine · doi:10.7326/m15-0744 · Cited by 599
Accepted but Unacceptable: Peripheral IV Catheter Failure
Helm, R. E., Klausner, J. D., Klemperer, J. D., Flint, L. M., & Huang, E. (2015) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000100 · Cited by 445 · cited 1×
“Hair unclipped at insertion 609 (39) 75 (12) 73 (12) 58 (10)”
Rickard, C. M., Webster, J., Wallis, M. C., Marsh, N., McGrail, M. R., French, V., Foster, L., Gallagher, P., Gowardman, J. R., Zhang, L., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61082-4 · Cited by 428
Self-citationThe 2016 Infusion Therapy Standards of Practice
(2017) · Home Healthcare Now · doi:10.1097/nhh.0000000000000504 · Cited by 360
Wallis, M. C., McGrail, M., Webster, J., Marsh, N., Gowardman, J., Playford, E. G., & Rickard, C. M. (2014) · Infection Control & Hospital Epidemiology · doi:10.1086/674398 · Cited by 353
Self-citationClinically-indicated replacement versus routine replacement of peripheral venous catheters
Webster, J., Osborne, S., Rickard, C. M., & New, K. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007798.pub3 · Cited by 313
Self-citationPeripheral venous catheters: an under-evaluated problem
Zingg, W., & Pittet, D. (2009) · International Journal of Antimicrobial Agents · doi:10.1016/s0924-8579(09)70565-5 · Cited by 310
Jacobson, A. F., & Winslow, E. H. (2005) · Heart & Lung · doi:10.1016/j.hrtlng.2005.04.002 · Cited by 279
Reporting methods in studies developing prognostic models in cancer: a review
Mallett, S., Royston, P., Dutton, S., Waters, R., & Altman, D. G. (2010) · BMC Medicine · doi:10.1186/1741-7015-8-20 · Cited by 206 · cited 4×
“Skin integrity good fair poor 606 (61) 322 (32) 72 (7) 96 (16) 62 (19) 11 (15) 135 (22) 63 (20) 11 (15) 66 (11) 54 (17) 17 (24)”
InfluentialWebster, J., Clarke, S., Paterson, D., Hutton, A., Dyk, S. V., Gale, C., & Hopkins, T. (2008) · BMJ · doi:10.1136/bmj.a339 · Cited by 190
Self-citationInfusion phlebitis assessment measures: a systematic review
Ray‐Barruel, G., Polit, D. F., Murfield, J. E., & Rickard, C. M. (2014) · Journal of Evaluation in Clinical Practice · doi:10.1111/jep.12107 · Cited by 179
Self-citationClinically-indicated replacement versus routine replacement of peripheral venous catheters
Webster, J., Osborne, S. R., Rickard, C. M., & New, K. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007798.pub4 · Cited by 156
Self-citationAbolfotouh, M. A., Salam, M., Mustafa, A., White, D., & Balkhy, H. H. (2014) · Therapeutics and Clinical Risk Management · doi:10.2147/tcrm.s74685 · Cited by 149
Failed attempts and improvement strategies in peripheral intravenous catheterization
Sabri, A., Szalas, J., Holmes, K. S., Labib, L., & Mussivand, T. (2013) · Bio-Medical Materials and Engineering · doi:10.3233/bme-120735 · Cited by 146
Tuffaha, H., Rickard, C. M., Webster, J., Marsh, N. M., Gordon, L. G., Wallis, M. C., & Scuffham, P. (2014) · Applied Health Economics and Health Policy · doi:10.1007/s40258-013-0077-2 · Cited by 111
Self-citationPosition of peripheral venous cannulae and the incidence of thrombophlebitis: an observational study
Cicolini, G., Bonghi, A. P., Labio, L. D., & Mascio, R. D. (2009) · Journal of Advanced Nursing · doi:10.1111/j.1365-2648.2009.04980.x · Cited by 109
Fields, J. M., Dean, A. J., Todman, R. W., Au, A. K., Anderson, K. L., Ku, B. S., Pines, J. M., & Panebianco, N. L. (2011) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2011.07.027 · Cited by 95
Devices and dressings to secure peripheral venous catheters to prevent complications
Marsh, N. M., Webster, J., Mihala, G., & Rickard, C. M. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011070.pub2 · Cited by 95
Self-citationCatney, M. R., Hillis, S. L., Wakefield, B. J., Simpson, L., Domino, L., Keller, S., Connelly, T., White, M. L., Price, D., & Wagner, K. (2001) · Journal of Infusion Nursing · doi:10.1097/00129804-200109000-00008 · Cited by 85
Bausone-Gazda, D., Lefaiver, C. A., & Walters, S.-A. (2010) · Journal of Infusion Nursing · doi:10.1097/nan.0b013e3181f85be2 · Cited by 82
Keogh, S. J., Flynn, J. M., Marsh, N. M., Mihala, G., Davies, K. M., & Rickard, C. M. (2016) · Trials · doi:10.1186/s13063-016-1470-6 · Cited by 74
Self-citationWebster, J., Lloyd, S., Hopkins, T., Osborne, S. R., & Yaxley, M. (2006) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2006.02.003 · Cited by 72
Self-citationParker, S. I. A., Benzies, K., Hayden, A., & Lang, E. (2016) · International Emergency Nursing · doi:10.1016/j.ienj.2016.05.004 · Cited by 65
Epidemiology Of Infiltration And Phlebitis.
Saini, R., Agnihotri, M., Gupta, A., & Walia, I. (2011) · Nursing & Midwifery Research Journal · doi:10.1177/0974150x20110103 · Cited by 56
Palefski, S. S., & Stoddard, G. J. (2001) · PubMed · Cited by 53
Intermittently Delivered IV Medication and pH
Gorski, L. A., Hagle, M. E., & Bierman, S. (2015) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000081 · Cited by 48
Improving peripheral cannulation practice at an NHS Trust
Bolton, D. (2010) · British Journal of Nursing · doi:10.12968/bjon.2010.19.21.79998 · Cited by 46
Maintenance of Peripheral Venous Access and Its Impact on the Development of Phlebitis
Furtado, L. (2011) · Journal of Infusion Nursing · doi:10.1097/nan.0b013e318230636b · Cited by 44
Factors that affect longevity of intravenous cannulas: a prospective study
Dillon, M. F., Curran, J., Martos, R., Walsh, C., Walsh, J. A., Alazawi, D. K., Lee, C. S., & O’Shea, D. (2008) · QJM · doi:10.1093/qjmed/hcn078 · Cited by 44
A Clinical Trial of a New All-in-One Peripheral Short Catheter
McNeill, E. E., Hines, N. L., & Phariss, R. (2009) · Journal of the Association for Vascular Access · doi:10.2309/java.14-1-8 · Cited by 20
Prehospital Peripheral Venous Catheters: A Prospective Study of Patient Complications
Göransson, K. E., & Johansson, E. M. (2011) · The Journal of Vascular Access · doi:10.5301/jva.2011.8418 · Cited by 20
Cited by
Use of Short Peripheral Intravenous Catheters: Characteristics, Management, and Outcomes Worldwide
Alexandrou, E., Ray‐Barruel, G., Carr, P. J., Frost, S. A., Inwood, S., Higgins, N., Lin, F., Alberto, L., Mermel, L., Rickard, C. M., et al. (2018) · Journal of Hospital Medicine · doi:10.12788/jhm.3039 · Cited by 430
Self-citationBest practice in the use of peripheral venous catheters: A scoping review and expert consensus
Zingg, W., Barton, A., Bitmead, J., Eggimann, P., Pujol, M., Simon, A., & Tatzel, J. (2023) · Infection Prevention in Practice · doi:10.1016/j.infpip.2023.100271 · Cited by 85
“Failure ratios of 32% and 41% were reported by Marsh [32] and Rickard [33], respectively.”
Backgroundvan Loon, F. H., Leggett, T., Bouwman, A. R., & Dierick-van Daele, A. T. (2020) · The Journal of Vascular Access · doi:10.1177/1129729820901653 · Cited by 46
Carr, P. J., Rippey, J. C. R., Cooke, M. L., Higgins, N. S., Trevenen, M., Foale, A., & Rickard, C. M. (2018) · Infection Control & Hospital Epidemiology · doi:10.1017/ice.2018.190 · Cited by 48
Self-citationSchults, J. A., Calleja, P., Slaughter, E., Paterson, R., Rickard, C. M., Booker, C., Marsh, N., Fenn, M., Kelly, J., Snelling, P. J., et al. (2022) · PLOS ONE · doi:10.1371/journal.pone.0269788 · Cited by 35
Self-citation
Metadata
- Authors
- Marsh, N., Webster, J., Larsen, E., Cooke, M., Mihala, G., & Rickard, C. M.
- Venue
- Journal of Hospital Medicine
- Publisher
- Wiley
- Published
- 2017-10-18
- Volume
- 13
- Issue
- 2
- Pages
- 83-89
- ISSN
- 1553-5592 (ISSN-L)
- 1553-5606
- OpenAlex
- W2765339054
- Cited by
- 267
- References
- 34
- FWCI
- 25.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.