Cited by 33Vitamin C and Antioxidants ResearchAnalytical Methods in PharmaceuticalsAnalytical Chemistry and Chromatography

HPLC-UV method for the simultaneous determinations of ascorbic acid and dehydroascorbic acid in human plasma

Open access
Kim, Yunjeong, Kim, Min-Gul·2016·Translational and Clinical Pharmacology

Abstract

A high performance liquid chromatography (HPLC) paired with UV-vis detection method to determine ascorbic acid and its oxidation product, dehydroascorbic acid, in human plasma was developed. Ascorbic acid in human plasma was extracted and stabilized using 10% metaphosphoric acid, and was analyzed by a Symmetry C18 column with 5 mM Hexadecyltrimethylammonium bromide and 50 mM KH2PO4 solution as the mobile phase (1.0 mL/min flow rate). Isoascorbic acid served as the internal standard and ultraviolet detector wavelength was 254 nm and 265 nm. Dehydroascorbic acid concentration was calculated from the differences in ascorbic acid concentration before and after reduction by dithiothreitol reagent. Quantification for ascorbic acid in human plasma was linear from 1–100 μg/mL. The interand intra-day precisions and accuracy were determined and the results were found to be within ±15%. This method was successfully applied to a human pharmacokinetic study of ascorbic acid as well as dehydroascorbic acid after oral administration of 4,000 mg vitamin C tablets to healthy Korean volunteers.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.12793/tcp.2016.24.1.37

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Vitamin C absorption is relatively slow, as maximal plasma levels are reached after 2-4 h.

    “In general, vitamin C absorption is relatively slow, as maximal plasma levels are reached after 2–4 h [6,8,40,58].”

    From Vitamin C-Sources, Physiological Role, Kinetics, Deficiency, Use, Toxicity, and Determination (2021) · cites this paper as [58]

    The Results (Pharmacokinetic study) report that plasma ascorbic acid reached its maximum at 2.67 ± 0.58 hours after a 4,000 mg oral dose, supporting the 2–4-hour timing. The study involved only three healthy volunteers and does not establish that vitamin C absorption is generally or relatively slow. (LLM, conf=0.86)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Kim, Y., & Kim, M.-G.
Affiliations
Jeonbuk National University Hospital (KR)
Venue
Translational and Clinical Pharmacology
Publisher
XMLink
Published
2016
Volume
24
Issue
1
Pages
37
ISSN
  • 2289-0882 (ISSN-L)
  • 2383-5427
OpenAlex
W2346983855
Cited by
33
References
21
Citations by year
2026: 3 · 2025: 6 · 2024: 3 · 2023: 2 · 2022: 9 · 2021: 5 · 2020: 1 · 2019: 1 · 2018: 3
FWCI
1.39
Type
journal article
Language
en
Open access
Locations
Translational and Clinical Pharmacology (publishedVersion, cc-by-nc)
Funders
Chonbuk National University Hospital
Topics
  • Health Sciences › Nursing › Nutrition and Dietetics › Vitamin C and Antioxidants Research
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
  • Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
Keywords
vitamin C, dehydroascorbic acid, human plasma, pharmacokinetics, HPLC-UV method, dithiothreitol reduction, simultaneous determination, oral administration

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›