Reference Values in White Europeans for the Arterial Pulse Wave Recorded by Means of the SphygmoCor Device
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Measurement of blood pressure together with applanation tonometry at the radial artery allows the reproducible assessment of various indexes of arterial stiffness, including the peripheral (PPp) and central pulse pressures (PPc) and the peripheral (Alp) and central augmentation indexes (Alc). We defined preliminary diagnostic thresholds, using the distributional characteristics of these hemodynamic measurements in a reference population. We randomly recruited 870 subjects from 3 European populations. PPp was the average difference between systolic and diastolic blood pressure measured five times at one home visit. For measurement of PPc, Alp and Alc, we used the SphygmoCor device. We selected subjects without hypertension, diabetes, dyslipidemia in need of medical treatment or previous or concomitant cardiovascular disease. The study population included 228 men and 306 women (mean age 34.9 years). All hemodynamic measurements were curvilinearly related to age, and Alp and Alc were lower in men than in women. In men at age 40, the upper 95% prediction bands of the relations of the hemodynamic measurements with age approximated 60 mmHg for PPp, 40 mmHg for PPc, 90% for Alp, and 30% for Alc. For PPc, Alp and Alc, these thresholds must be adjusted for age, leading to lower and higher thresholds at younger and older age, respectively. In addition, in women of any age, the Alp and Alc thresholds must be increased by 10% and 7%, respectively. Pending validation in prospective outcome studies, distributional characteristics of arterial stiffness indexes in a reference population can be used to generate operational thresholds for use in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
An analysis of variance test for normality (complete samples)
SHAPIRO, S. S., & WILK, M. B. (1965) · Biometrika · doi:10.1093/biomet/52.3-4.591 · Cited by 23,480
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Chen, C.-H., Nevo, E., Fetics, B., Pak, P. H., Yin, F. C. P., Maughan, W. L., & Kass, D. A. (1997) · Circulation · doi:10.1161/01.cir.95.7.1827 · Cited by 1,307 · cited 1×
“Such an approach may have led to a small degree of error in central pressure estimation, although the transfer function involved has been previously validated (1, 22).”
KARAMANOGLU, M., O'ROURKE, M. F., AVOLIO, A. P., & KELLY, R. P. (1993) · European Heart Journal · doi:10.1093/eurheartj/14.2.160 · Cited by 873 · cited 1×
“Such an approach may have led to a small degree of error in central pressure estimation, although the transfer function involved has been previously validated (1, 22).”
Hjemdahl, P., & Friberg, P. (1996) · Journal of Hypertension · doi:10.1097/00004872-199602000-00001 · Cited by 196
Cited by
Prediction of Cardiovascular Events and All-Cause Mortality With Arterial Stiffness
Vlachopoulos, C., Aznaouridis, K., & Stefanadis, C. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.10.061 · Cited by 4,165
“Reference values and cutoff points are important elements for clinical integration of arterial stiffness, and apart from published data (46–48), further studies are under way (49).”
Vlachopoulos, C., Aznaouridis, K., O'Rourke, M. F., Safar, M. E., Baou, K., & Stefanadis, C. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq024 · Cited by 1,363
Mechanical Factors in Arterial Aging
O’Rourke, M. F., & Hashimoto, J. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.12.050 · Cited by 1,250
Pini, R., Cavallini, M. C., Palmieri, V., Marchionni, N., Di Bari, M., Devereux, R. B., Masotti, G., & Roman, M. J. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.03.031 · Cited by 386
Herbert, A., Cruickshank, J. K., Laurent, S., & Boutouyrie, P. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu293 · Cited by 290
Metadata
- Authors
- WOJCIECHOWSKA, W., STAESSEN, J. A., NAWROT, T., CWYNAR, M., SEIDLEROVÁ, J., STOLARZ, K., GASOWSKI, J., TICHÁ, M., RICHART, T., THIJS, L., GRODZICKI, T., KAWECKA-JASZCZ, K., & FILIPOVSKY, J.
- Venue
- Hypertension Research
- Publisher
- Japanese Society of Hypertension
- Published
- 2006
- Volume
- 29
- Issue
- 7
- Pages
- 475-483
- ISSN
- 0916-9636 (ISSN-L)
- 1348-4214
- OpenAlex
- W1992175715
- Cited by
- 76
- References
- 6
- FWCI
- 5.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.