Airside heat transfer and pressure drop of louver-finned parallel flow heat exchanger having a drainage channel
Open accessAbstract
Conventional louver fins have an inherent problem of condensate drainage. In this study, a newly developed louver fin is introduced. The louver fin has downstream a drainage channel. The dry and the wet surface heat transfer and pressure drop characteristics of the new sample were investigated, and the results were compared with those of the conventional sample. Compared to the conventional sample, superior wet surface heat transfer and pressure drop characteristics were obtained. The j factors of the new sample were 40% larger, and the f factors were 9% smaller. In addition, the wet j and f factors were not much different from the dry ones, which imply that excellent condensate drainage is possible for the new fin. Under dry condition, however, poor heat transfer and pressure drop characteristics were obtained. The j factors of the conventional sample were 81% larger, and the f factors were 14% smaller. Allocation of the fin surface to flat (not enhanced) drainage channel for the new fin may be responsible. Under wet condition, j/f1/3 of the new sample was 45% larger than that of the conventional sample. Under dry condition, however, j/f1/3 of the conventional sample was 91% larger.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
By using novel louvered fins, j factors are increased up to 40% and f factors are decreased up to 9%.
“By using novel louvered fins, the j fac tors were increased up to 40% and f factors were decreased up to 9%.”
From Thermal-hydraulic and drainage performance of microchannel heat exchangers for refrigeration and heat pump systems under frosting, defrosting, and wet conditions: A comprehensive review (2023) · cites this paper as [96]
The Results and Discussions and Conclusions report that, under wet conditions, the new fin had a 40% higher j factor and a 9% lower f factor than the conventional fin. The claim omits that condition: under dry conditions, the paper reports the opposite trend. (LLM, conf=0.88)
Experimental — accuracy not yet measuredFor the new louvered fins, there is no significant difference in j and f factors on the wet surface compared with the dry surface, which proves excellent drainage performance.
“In addition, for the new louvered fins, there is no significant difference in j and f factors on the wet surface in comparison with the dry surface, which proved that the new louvered fins had excellent drainage performance.”
From Thermal-hydraulic and drainage performance of microchannel heat exchangers for refrigeration and heat pump systems under frosting, defrosting, and wet conditions: A comprehensive review (2023) · cites this paper as [96]
The Results and Discussions section says the new fin’s wet j and f factors were not much different from its dry factors and interprets this as implying that excellent condensate drainage is possible. The Conclusions repeat that interpretation. The citing sentence overstates the inference by saying the comparison proved excellent drainage performance. (LLM, conf=0.86)
Experimental — accuracy not yet measuredThe new louvered-fin MCHX has better wet surface thermal-hydraulic performance than the conventional MCHX.
“According to the results, the new louvered-fin MCHX had better wet surface thermal-hydraulic performance than the conventional MCHX.”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Heat transfer and pressure drop characteristics of flat tube and louvered plate fin surfaces
Achaichia, A., & Cowell, T. A. (1988) · Experimental Thermal and Fluid Science · doi:10.1016/0894-1777(88)90032-5 · Cited by 235 · see citing works
Zhang, P., & Hrnjak, P. S. (2009) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2008.11.006 · Cited by 75 · see citing works
Xu, B., Zhang, C., Wang, Y., Chen, J., Xu, K., Li, F., & Wang, N. (2015) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2015.06.037 · Cited by 69 · see citing works
Kim, M.-H., Kim, H., Kim, D. R., & Lee, K.-S. (2016) · Energy Conversion and Management · doi:10.1016/j.enconman.2015.11.028 · Cited by 68 · see citing works
Kim, M.-H., Song, S., & Bullard, C. W. (2002) · International Journal of Refrigeration · doi:10.1016/s0140-7007(01)00061-5 · Cited by 39 · see citing works
Effect of some geometric parameters on performance of PF2 heat exchangers in periodic frosting
Zhang, P., & Hrnjak, P. S. (2010) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2009.11.004 · Cited by 38 · see citing works
Water condensate retention and “wet” fin performance in automotive evaporators
Zhang, C. A., Hu, H., Jacobi, A. M., & Kaiser, J. M. (2001) · SAE Technical Paper Series · doi:10.4271/2001-01-1252 · Cited by 3 · see citing works
Flagged first, then by citations
Research works printed but not linked: 23
- Achaichia, A. and Cowell, T. A., A finite difference analysis of fully developed periodic laminar flow in inclined louvered arrays, Proceedings of Second UK National Heat Transfer Conference, Glasgow (1988b). pp.883-888.
- Achaichia, A., Heikal, M. R., Sulaimna, Y. and Cowell, T. A., Numerical Investigation of flow and friction in louver fin arrays, Proceedings of the Tenth International Heat Transfer Conference, Vol. 4 (1994), pp. 333-338. ASHRAE Standard 41.1, Standard Method for Temperature Measurement, ASHRAE (1986). ASHRAE Standard 41.2, Standard Method for Laboratory Air-Flow, ASHRAE (1987). [DOI: 10.1299/jtst.2018jtst0018]
- Kim and Cho, Journal of Thermal Science and Technology, Vol.13, No.1 (2018) ASHRAE Standard 41.5, Standard Measurement Guide, Engineering Analysis of Experimental Data, ASHRAE (1975).
- Chang, Y.-J. and Wang, C.-C., Air-side performance of brazed aluminum heat exchangers, J. Enhanced Heat Transfer, Vol. 3, No. 1 (1996), pp. 15-28.
- Davenport, C. J., Correlation of heat transfer and flow friction characteristics of louvered fin, AIChE Symp. Ser., Vol. 79 (1983), pp. 19-27.
- Diani, A., Rossetto, L., Dall'Olio, R., De Zen, D. and Masetto, F., Heat and mass transfer to air in a cross flow heat exchanger with surface deluge cooling, Int. J. Air-Cond. Refrig., Vol. 24, No. 1 (2016), Paper No. 1650002.
- Gnielinski, V., New equation for heat and mass transfer in turbulent pipe and channel flow, Int. Chem. Eng., Vol. 16 (1976), pp. 359-368.
- Hiramatsu, M., Ishimaru, T. and Matsuzaki, K., Research on fins for air-conditioning heat exchangers (first report, numerical analysis of heat transfer on louvered fins), JSME International Journal, Series II, Vol. 33, No.4 (1990), Paper No. 88-1254A.
- Kang, C. S. and Choi, T. M., A basic study on air flow characteristics in louvered fins, KSME J., Vol. 17, No. 5 (1993), pp. 1276-1293.
- Kays, W. M. and London, A. L., Compact Heat Exchangers, 3 rd Ed., McGraw-Hill (1984).
- Kim, M.-H. and Park, W.-Y., Air-side heat transfer and pressure drop characteristics of louvered fin heat exchanges, Proc. KSME 1998 Fall Conference (1998), pp. 123-128.
- Kim, M.-H. and Bullard, C.-W., Airside performance of brazed aluminum heat exchanger under dehumidifying conditions, Int. J. Refrigeration, Vol. 25 (2002), pp. 924-934.
- Kim, M.-H., Youn, B. and Bullard, C. W., Effect of inclination angle on the air-side performance of a brazed aluminum heat exchanger under dry and wet conditions, Int. J. Heat Mass Transfer, Vol. 44 (2001), pp. 4613-4623.
- Kim, N.-H. and Cho, J.-P., Air-side performance of louver-finned flat aluminum heat exchanges at a low velocity region, Heat Mass Transfer, Vol. 44 (2008), pp. 1127-1139.
- Kim, N.-H. and Kim, S.-H., Dry and wet air-side performance of a louver-finned heat exchanger having flat tube, J. Mech. Sci. Tech., Vol. 24, No. 7, (2010) pp. 1553-1561.
- Kim, N.-H., Kim, D.-Y. and Hwang, J.-H., Wet surface heat transfer and pressure drop of aluminum parallel flow heat exchangers at different inclination angles, J. Mech. Sci. Tech., Vol. 22 (2008), pp. 1-11.
- Lee, K. S., Jeon, C. D. and Lee, J. H., Study of flow structure and pressure drop characteristics in louvered-fin type heat exchanger, J. SAREK, Vol. 6, No. 2 (1994), pp. 140-154.
- Suga, K., Aoki, H. and Shingawa, T., Numerical analysis on two dimensional flow and heat transfer on louvered fins using overlaid grids, JSME International Journal, Vol. 33 (1990), pp. 122-127.
- Sunden, B. and Svantessen, B. J., Correlation of j and f factors for multi-louvered heat transfer surfaces, Proceedings of Third UK National Heat Transfer Conference (1992), pp. 805-811.
- Tafti, D. K., Wang, G. and Lin, W., Flow transition in a multi-louvered fin array, Int. J. Heat Mass Transfer, Vol. 43 (2000), pp. 901-919.
- Youn, B., Kim, Y.-S., Park H.-Y. and Kim, N.-H., An experimental investigation on the airside performance of fin-and-tube heat exchangers having radial slit fins, J. Enhanced Heat Transfer, Vol. 10, No. 1 (2003), pp. 61-80.
- Kim and Cho, Journal of Thermal Science and Technology, Vol.13, No.1 (2018)
- Zhang, P. and Hrnjak, P., Air-side performance of a parallel-flow parallel-fin (PF2) heat exchanger in sequential frosting, Int. J. Refrig., Vol. 33 (2010b), pp. 1118-1128.
Cited by
Sorted by citations
Li, F., Wu, S., Ma, Z., Zhao, R., & Huang, D. (2022) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.118220 · Cited by 36 · see citing works
Xiong, T., Liu, G., Gao, Q., Yan, G., & Yu, J. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105654 · Cited by 26 · see citing works
- Authors
- KIM, N.-H., & CHO, H.
- Affiliations
- Incheon National University (KR)
- Samsung Electronics (South Korea) (KR)
- Venue
- Journal of Thermal Science and Technology
- Published
- 2018
- Volume
- 13
- Issue
- 1
- Pages
- JTST0018-JTST0018
- ISSN
- 1880-5566 (ISSN-L)
- OpenAlex
- W2808602537
- Cited by
- 15
- References
- 7
- Citations by year
- 2026: 4 · 2025: 2 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 1
- FWCI
- 0.64
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Journal of Thermal Science and Technology (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- Incheon National University
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer Mechanisms
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Boiling Studies
- Keywords
- louver fins, parallel flow heat exchanger, condensate drainage, drainage channels, air-side heat transfer, pressure drop
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review