Cited by 15Heat Transfer and OptimizationHeat Transfer MechanismsHeat Transfer and Boiling Studies

Airside heat transfer and pressure drop of louver-finned parallel flow heat exchanger having a drainage channel

Open access
KIM, Nae-Hyun, CHO, Honggi·2018·Journal of Thermal Science and Technology

Abstract

Conventional louver fins have an inherent problem of condensate drainage. In this study, a newly developed louver fin is introduced. The louver fin has downstream a drainage channel. The dry and the wet surface heat transfer and pressure drop characteristics of the new sample were investigated, and the results were compared with those of the conventional sample. Compared to the conventional sample, superior wet surface heat transfer and pressure drop characteristics were obtained. The j factors of the new sample were 40% larger, and the f factors were 9% smaller. In addition, the wet j and f factors were not much different from the dry ones, which imply that excellent condensate drainage is possible for the new fin. Under dry condition, however, poor heat transfer and pressure drop characteristics were obtained. The j factors of the conventional sample were 81% larger, and the f factors were 14% smaller. Allocation of the fin surface to flat (not enhanced) drainage channel for the new fin may be responsible. Under wet condition, j/f1/3 of the new sample was 45% larger than that of the conventional sample. Under dry condition, however, j/f1/3 of the conventional sample was 91% larger.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1299/jtst.2018jtst0018

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 23

  1. Achaichia, A. and Cowell, T. A., A finite difference analysis of fully developed periodic laminar flow in inclined louvered arrays, Proceedings of Second UK National Heat Transfer Conference, Glasgow (1988b). pp.883-888.
  2. Achaichia, A., Heikal, M. R., Sulaimna, Y. and Cowell, T. A., Numerical Investigation of flow and friction in louver fin arrays, Proceedings of the Tenth International Heat Transfer Conference, Vol. 4 (1994), pp. 333-338. ASHRAE Standard 41.1, Standard Method for Temperature Measurement, ASHRAE (1986). ASHRAE Standard 41.2, Standard Method for Laboratory Air-Flow, ASHRAE (1987). [DOI: 10.1299/jtst.2018jtst0018]
  3. Kim and Cho, Journal of Thermal Science and Technology, Vol.13, No.1 (2018) ASHRAE Standard 41.5, Standard Measurement Guide, Engineering Analysis of Experimental Data, ASHRAE (1975).
  4. Chang, Y.-J. and Wang, C.-C., Air-side performance of brazed aluminum heat exchangers, J. Enhanced Heat Transfer, Vol. 3, No. 1 (1996), pp. 15-28.
  5. Davenport, C. J., Correlation of heat transfer and flow friction characteristics of louvered fin, AIChE Symp. Ser., Vol. 79 (1983), pp. 19-27.
  6. Diani, A., Rossetto, L., Dall'Olio, R., De Zen, D. and Masetto, F., Heat and mass transfer to air in a cross flow heat exchanger with surface deluge cooling, Int. J. Air-Cond. Refrig., Vol. 24, No. 1 (2016), Paper No. 1650002.
  7. Gnielinski, V., New equation for heat and mass transfer in turbulent pipe and channel flow, Int. Chem. Eng., Vol. 16 (1976), pp. 359-368.
  8. Hiramatsu, M., Ishimaru, T. and Matsuzaki, K., Research on fins for air-conditioning heat exchangers (first report, numerical analysis of heat transfer on louvered fins), JSME International Journal, Series II, Vol. 33, No.4 (1990), Paper No. 88-1254A.
  9. Kang, C. S. and Choi, T. M., A basic study on air flow characteristics in louvered fins, KSME J., Vol. 17, No. 5 (1993), pp. 1276-1293.
  10. Kays, W. M. and London, A. L., Compact Heat Exchangers, 3 rd Ed., McGraw-Hill (1984).
  11. Kim, M.-H. and Park, W.-Y., Air-side heat transfer and pressure drop characteristics of louvered fin heat exchanges, Proc. KSME 1998 Fall Conference (1998), pp. 123-128.
  12. Kim, M.-H. and Bullard, C.-W., Airside performance of brazed aluminum heat exchanger under dehumidifying conditions, Int. J. Refrigeration, Vol. 25 (2002), pp. 924-934.
  13. Kim, M.-H., Youn, B. and Bullard, C. W., Effect of inclination angle on the air-side performance of a brazed aluminum heat exchanger under dry and wet conditions, Int. J. Heat Mass Transfer, Vol. 44 (2001), pp. 4613-4623.
  14. Kim, N.-H. and Cho, J.-P., Air-side performance of louver-finned flat aluminum heat exchanges at a low velocity region, Heat Mass Transfer, Vol. 44 (2008), pp. 1127-1139.
  15. Kim, N.-H. and Kim, S.-H., Dry and wet air-side performance of a louver-finned heat exchanger having flat tube, J. Mech. Sci. Tech., Vol. 24, No. 7, (2010) pp. 1553-1561.
  16. Kim, N.-H., Kim, D.-Y. and Hwang, J.-H., Wet surface heat transfer and pressure drop of aluminum parallel flow heat exchangers at different inclination angles, J. Mech. Sci. Tech., Vol. 22 (2008), pp. 1-11.
  17. Lee, K. S., Jeon, C. D. and Lee, J. H., Study of flow structure and pressure drop characteristics in louvered-fin type heat exchanger, J. SAREK, Vol. 6, No. 2 (1994), pp. 140-154.
  18. Suga, K., Aoki, H. and Shingawa, T., Numerical analysis on two dimensional flow and heat transfer on louvered fins using overlaid grids, JSME International Journal, Vol. 33 (1990), pp. 122-127.
  19. Sunden, B. and Svantessen, B. J., Correlation of j and f factors for multi-louvered heat transfer surfaces, Proceedings of Third UK National Heat Transfer Conference (1992), pp. 805-811.
  20. Tafti, D. K., Wang, G. and Lin, W., Flow transition in a multi-louvered fin array, Int. J. Heat Mass Transfer, Vol. 43 (2000), pp. 901-919.
  21. Youn, B., Kim, Y.-S., Park H.-Y. and Kim, N.-H., An experimental investigation on the airside performance of fin-and-tube heat exchangers having radial slit fins, J. Enhanced Heat Transfer, Vol. 10, No. 1 (2003), pp. 61-80.
  22. Kim and Cho, Journal of Thermal Science and Technology, Vol.13, No.1 (2018)
  23. Zhang, P. and Hrnjak, P., Air-side performance of a parallel-flow parallel-fin (PF2) heat exchanger in sequential frosting, Int. J. Refrig., Vol. 33 (2010b), pp. 1118-1128.

Authors
KIM, N.-H., & CHO, H.
Affiliations
  • Incheon National University (KR)
  • Samsung Electronics (South Korea) (KR)
Venue
Journal of Thermal Science and Technology
Published
2018
Volume
13
Issue
1
Pages
JTST0018-JTST0018
ISSN
1880-5566 (ISSN-L)
OpenAlex
W2808602537
Cited by
15
References
7
Citations by year
2026: 4 · 2025: 2 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 1
FWCI
0.64
Type
journal article
Language
en
Open access
Locations
  • Journal of Thermal Science and Technology (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
Incheon National University
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer Mechanisms
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Boiling Studies
Keywords
louver fins, parallel flow heat exchanger, condensate drainage, drainage channels, air-side heat transfer, pressure drop

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review