Cited by 38Heat Transfer and OptimizationRefrigeration and Air Conditioning TechnologiesHeat Transfer Mechanisms

Effect of some geometric parameters on performance of PF2 heat exchangers in periodic frosting

Zhang, Ping, Hrnjak, P.S.·2010·International Journal of Refrigeration

Abstract

The thermal performance under conditions of initial frost growth and subsequent refrosting after a defrost is experimentally studied for the parallel flow parallel fin (PF2) heat exchanger, a new style of heat exchanger that uses louvered bent fins on flat tubes to enhance water drainage when the flat tubes are horizontal (typically outdoor heat exchanger in heat pump operation). This paper focuses on quantification of the effects of geometry (i.e. fin pitch 12–22fpi and louver pitch 1.4–2.8mm) on defrost and refrost times. Eight heat exchangers differing in louver pitch and fin spacing are studied. A series of tests are conducted in search for the best geometry. The effects of geometry on heat transfer (thermal performance) and pressure drop for air face velocities of 0.9, 2, and 3m/s are determined and used for comparison. Characteristics of initial heat transfer coefficient and pressure drop during the first frosting cycle are reported in terms of Colburn j0 factor and Fanning friction f0 factor, as a function of ReLp and geometry. The newly developed air-side correlations for PF2 heat exchangers (Colburn j0 factor and Fanning friction f0 factor) predict the test data within rms error of ±10%, and with mean deviation of 2.95% and 4.98%, respectively. The correlations are base on a very low Reynolds numbers in the range of 100–620, and 8 PF2 heat exchangers using 48 experimental data.

Integrity signals

Registry

Crossref · 10.1016/j.ijrefrig.2009.11.004

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

1 of the 16 references couldn’t be matched to a known paper.

Research works printed but not linked: 4

  1. Itoh, M., Kogure, H., Yoshinaga, S., Hoshino, R., Wakabayashi, N., Kudoh, M., Kusumoto, H. Study on parallel-flow-type heat exchangers for residential heat pump systems. In: Proceedings of the 1996 JAR Annual Conference, 1996, pp. 73–76.
  2. Kim, J., Groll, E.A. Performance comparisons of a unitary split system using microchannel and fin-tube out-door coils. In: Proceedings of the 2002 International Refrigeration and Air Conditioning Conference at Purdue, vol. I, 2002, pp. 249–256.
  3. Kondepudi, 1987, The effect of frost growth on extended surface heat exchanger performance – a review, ASHRAE Trans., 93, 258
  4. Shah, R.K. Thermal entry length solutions for circular tube and parallel plates. In: Proc. 3rd National heat mass transfer conference, Indian Inst. Technology, Bombay, vol. 1, 1975, HTM-11-75.

Cited by

Sorted by citations

Authors
Zhang, P., & Hrnjak, P. S.
Affiliations
University of Illinois Urbana-Champaign (US)
Corresponding author
Hrnjak, P.S.
Venue
International Journal of Refrigeration
Publisher
Elsevier BV
Published
2010-03
Volume
33
Issue
2
Pages
334-346
ISSN
0140-7007 (ISSN-L)
OpenAlex
W2056410721
Cited by
38
References
16
Citations by year
2026: 5 · 2025: 4 · 2024: 5 · 2023: 2 · 2022: 4 · 2021: 2 · 2020: 3 · 2019: 3 · 2018: 2 · 2017: 4 · 2016: 1 · 2015: 1 · 2014: 1 · 2012: 1
FWCI
0.67
Type
journal article
Language
en
Open access
closed
Locations
International Journal of Refrigeration (publishedVersion)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer Mechanisms
Keywords
thawing, fin spacing, fin geometry, air-side heat transfer, pressure drop, Colburn j-factor, Fanning friction factor, outdoor heat exchanger

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review