Cable-driven parallel mechanisms: state of the art and perspectives
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
This paper presents a review of the state of the art in the area of cable-driven parallel mechanisms. The basic kinematic architecture of cable-driven parallel mechanisms is first recalled and the associated kinematic and static model is briefly exposed. Fundamental problems are formulated, including the definition of the wrench matrix, the wrench-closure workspace and the wrench-feasible workspace. Advances that have been made in the determination of such workspaces are reported. The dynamics and control of cable-driven parallel mechanisms are then considered, first for fully constrained cable-driven parallel mechanisms and secondly for cable-suspended parallel mechanisms. Calibration and identification issues are also addressed and various alternative architectures of cable-driven parallel mechanisms are reported. Finally, applications are considered and open issues are mentioned.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751 · cited 1×
“An active leg exoskeleton robot based on a CDPM is introduced in [95] and a wearable upper-limb exoskeleton system based on a CDPM is developed in [96–98] following a similar approach.”
MethodCooperative manipulation and transportation with aerial robots
Michael, N., Fink, J., & Kumar, V. (2011) · Autonomous Robots · doi:10.1007/s10514-010-9205-0 · Cited by 637 · cited 1×
“applications of CSPMs in three-dimensional printing are starting to emerge [144] while cooperating flying vehicles are proposed in [145] and the dynamic trajectory planning of CSPMs described in [69,70] is suitable for artistic performances.”
BackgroundCooperative Manipulation and Transportation with Aerial Robots
Michael, N., Fink, J., & Kumar, V. (2010) · Robotics · doi:10.7551/mitpress/8727.003.0002 · Cited by 467
Design of a Cable-Driven Arm Exoskeleton (CAREX) for Neural Rehabilitation
Mao, Y., & Agrawal, S. K. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2012.2189496 · Cited by 409
Dynamic modeling and active control of a cable-suspended parallel robot
Zi, B., Duan, B. Y., Du, J., & Bao, H. (2007) · Mechatronics · doi:10.1016/j.mechatronics.2007.09.004 · Cited by 342 · cited 1×
“In [58], a fuzzy controller is proposed while [59] uses a backstepping approach to control a 3-dof CDPM.”
MethodDevelopment of an ultrahigh speed robot FALCON using wire drive system
Kawamura, S., Choe, W., Tanaka, S., & Pandian, S. R. (2002) · Proceedings of 1995 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.1995.525288 · Cited by 334
IPAnema: A family of Cable-Driven Parallel Robots for Industrial Applications
Pott, A., Mütherich, H., Kraus, W., Schmidt, V., Miermeister, P., & Verl, A. W. (2012) · Mechanisms and machine science · doi:10.1007/978-3-642-31988-4_8 · Cited by 211
Analysis of the Workspace of Tendon-based Stewart Platforms
Verhoeven, R. (2004) · DuEPublico (University of Duisburg-Essen) · Cited by 201
Variable geometry truss and its application to deployable truss and space crane arm
Miura, K., Furuya, H., & Suzuki, K. (1985) · Acta Astronautica · doi:10.1016/0094-5765(85)90131-6 · Cited by 193
Robot assisted gait training with active leg exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2008) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2008.4762885 · Cited by 140
A 3D Spatial Interface Device Using Tensed Strings
Ishii, M., & Sato, M. (1994) · PRESENCE Virtual and Augmented Reality · doi:10.1162/pres.1994.3.1.81 · Cited by 124
Lau, D., Oetomo, D., & Halgamuge, S. K. (2013) · IEEE Transactions on Robotics · doi:10.1109/tro.2013.2264866 · Cited by 114 · cited 1×
“The topological modelling was further generalised in [94] using the concept of cable routing matrix.”
MethodSPIDAR G&G: A Two-Handed Haptic Interface for Bimanual VR Interaction
Murayama, J., Bougrila, L., Akahane, K., Hasegawa, S., & Sato, M. (2004) · Cited by 110
Cable-Suspended Haptic Interface
Williams, R. L., II (1998) · International Journal of Virtual Reality · doi:10.20870/ijvr.1998.3.3.2627 · Cited by 93
A planar 3DOF robotic exoskeleton for rehabilitation and assessment
Ball, S. J., Brown, I. E., & Scott, S. H. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353216 · Cited by 85 · cited 1×
“In [131], a fixed-base planar mechanism driven with cables was proposed for upper arm rehabilitation and the performance of CSPMs for rehabilitation is assessed in [132].”
Vision-based modeling and control of large-dimension cable-driven parallel robots
Dallej, T., Gouttefarde, M., Andreff, N., Dahmouche, R., & Martinet, P. (2012) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2012.6385504 · Cited by 63
Realization of a virtual sports training system with parallel wire mechanism
Morizono, T., Kurahashi, K., & Kawamura, S. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1997.606747 · Cited by 61
A versatile wire robot concept as a haptic interface for sport simulation
v. Zitzewitz, J., Rauter, G., Steiner, R., Brunschweiler, A., & Riener, R. (2009) · 2009 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2009.5152219 · Cited by 58
Computing the lowest equilibrium pose of a cable-suspended rigid body
Collard, J.-F., & Cardou, P. (2012) · Optimization and Engineering · doi:10.1007/s11081-012-9191-5 · Cited by 35 · cited 1×
“In [38], the determination of the static pose of a CSPM with an arbitrary number of cables was formulated as an optimization problem having well-defined properties, which was solved globally to yield the”
BackgroundMao, Y., & Agrawal, S. K. (2010) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2010.5509823 · Cited by 31
Wire Robot Suspension Systems for Wind Tunnels
Sturm, C., Lalo, W., & Bruckm, T. (2011) · InTech eBooks · doi:10.5772/21578 · Cited by 15
Design and Control of a Wire-driven Haptic Device: HapticPen
Farahani, H. S., & Ryu, J. (2005) · Cited by 2
Cited by
Wireality: Enabling Complex Tangible Geometries in Virtual Reality with Worn Multi-String Haptics
Fang, C., Zhang, Y., Dworman, M., & Harrison, C. (2020) · Proceedings of the 2020 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3313831.3376470 · Cited by 149
“Please also see [19] for a more extensive review.”
Background
Metadata
- Authors
- GOSSELIN, C.
- Venue
- Mechanical Engineering Reviews
- Published
- 2014
- Volume
- 1
- Issue
- 1
- Pages
- DSM0004-DSM0004
- ISSN
- 2187-9753 (ISSN-L)
- OpenAlex
- W2020966348
- Cited by
- 168
- References
- 22
- FWCI
- 7.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.