The treatment of fractures with a dynamic axial fixator
Open accessThe DOI matches its Crossref record.
Abstract
The results obtained with a lightweight dynamic axial fixator in the treatment of fractures are reported. The apparatus comprises a single bar with articulating ends which clamp self-tapping screws and can be locked at an angle appropriate for axial alignment. A telescopic facility allows ready conversion from rigid to dynamic fixation once periosteal callus formation has commenced. Reduction and controlled distraction or compression are achieved by means of a detachable compressor unit. We treated 288 patients with fresh fractures and 50 with ununited fractures. The success rate for fresh fractures was 94%, with average healing times ranging from 3.4 to 6.5 months. In ununited fractures also, the success rate was 94% with average healing times ranging from 4.7 to 6.5 months. Complications were minimal. The device is versatile and can be applied in an average of 15 minutes. It permits ambulatory fracture care without sacrificing a sound anatomical result.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A new antibacterial titanium–copper sintered alloy: Preparation and antibacterial property
Zhang, E., Li, F., Wang, H., Liu, J., Wang, C., Li, M., & Yang, K. (2013) · Materials Science and Engineering: C · doi:10.1016/j.msec.2013.06.016 · Cited by 325
KEATING, J. F., OʼBRIEN, P. J., BLACHUT, P. A., MEEK, R. N., & BROEKHUYSE, H. M. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199703000-00003 · Cited by 321
Axial movement and tibial fractures. A controlled randomised trial of treatment
Kenwright, J., Richardson, J., Cunningham, J., White, S., Goodship, A., Adams, M., Magnussen, P., & Newman, J. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b4.2071654 · Cited by 295
Strain Rate and Timing of Stimulation in Mechanical Modulation of Fracture Healing
Goodship, A. E., Cunningham, J. L., & Kenwright, J. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810001-00012 · Cited by 229
Measuring stiffness can define healing of tibial fractures
Richardson, J., Cunningham, J., Goodship, A., O'Connor, B., & Kenwright, J. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b3.8175839 · Cited by 204
Prevention of pin tract infection with titanium‐copper alloys
Shirai, T., Tsuchiya, H., Shimizu, T., Ohtani, K., Zen, Y., & Tomita, K. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31412 · Cited by 199
“Infection rate in external fixation occurs in 2-30% of cases found in the literature.(6-10) In a report of pin tract infection, Mahan described 75% of screw tips cultured positive for infection at removal.”
BackgroundGlatt, V., Evans, C. H., & Tetsworth, K. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2016.00678 · Cited by 194
“It is often used when an implant allows axial shortening of a bone through a telescoping mechanism incorporated into the fixation device (De Bastiani et al., 1984).”
BackgroundClaes, L., Blakytny, R., Besse, J., Bausewein, C., Ignatius, A., & Willie, B. (2011) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0b013e3181e3d994 · Cited by 75
Metadata
- Authors
- De Bastiani, G., Aldegheri, R., & Renzi Brivio, L.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 1984-08
- Volume
- 66-B
- Issue
- 4
- Pages
- 538-545
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2145501092
- Cited by
- 306
- References
- 0
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.