Bonding of bone to apatite-coated implants
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Implants of solid sintered hydroxyapatite form very tight bonds with living bone, but are susceptible to fatigue failure. This problem can be overcome by using plasma-sprayed apatite coatings on titanium implants. A very strong bond is formed between bone and this composite material; this was studied in canine bone with plug implants, avoiding any mechanical retention. Mechanical testing showed an interface shear strength at six weeks of 49 MPa with a maximum of 64 MPa after six months. There was histological evidence of direct bonding between the apatite coating and living bone while uncoated control plugs were easily extracted. The results indicate that apatite-coated implants can form a chemical fixation with a strength comparable to that of cortical bone itself. This fixation is far stronger than that provided by current cemented or uncemented fixation techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calcium Phosphate Ceramics as Hard Tissue Prosthetics
JARCHO, M. (1981) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198106000-00037 · Cited by 2,014
Goldring, S. R., Schiller, A. L., Roelke, M., Rourke, C. M., OʼNeil, D. A., & Harris, W. H. (1983) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198365050-00001 · Cited by 849
The Optimum Pore Size for the Fixation of Porous-Surfaced Metal Implants by the Ingrowth of Bone
BOBYN, J. D., PILLIAR, R. M., CAMERON, H. U., & WEATHERLY, G. C. (1980) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198007000-00045 · Cited by 832
Tissue response to dense apatite implants in rats
Denissen, H. W., de Groot, K., Makkes, P. C., van den Hooff, A., & Klopper, P. J. (1980) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820140603 · Cited by 241
Self-citationHalawa, M., Lee, A. J. C., Ling, R. S. M., & Vangala, S. S. (1978) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/bf00381636 · Cited by 192
Cited by
Material fundamentals and clinical performance of plasma‐sprayed hydroxyapatite coatings: A review
Sun, L., Berndt, C. C., Gross, K. A., & Kucuk, A. (2001) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1056 · Cited by 1,065
Understanding Peri‐Implant Endosseous Healing
Davies, J. E. (2003) · Journal of Dental Education · doi:10.1002/j.0022-0337.2003.67.8.tb03681.x · Cited by 1,063
Antibacterial surfaces: the quest for a new generation of biomaterials
Hasan, J., Crawford, R. J., & Ivanova, E. P. (2013) · Trends in Biotechnology · doi:10.1016/j.tibtech.2013.01.017 · Cited by 955
Synthetic bone graft substitutes
Moore, W. R., Graves, S. E., & Bain, G. I. (2001) · ANZ Journal of Surgery · doi:10.1046/j.1440-1622.2001.02128.x · Cited by 826
The future of biologic coatings for orthopaedic implants
Goodman, S. B., Yao, Z., Keeney, M., & Yang, F. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.01.074 · Cited by 779
Metadata
- Authors
- Geesink, R., de Groot, K., & Klein, C.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 1988-01
- Volume
- 70-B
- Issue
- 1
- Pages
- 17-22
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2105918224
- Cited by
- 537
- References
- 5
- FWCI
- 8.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.