Abstract

Forty years ago, Lundberg introduced the concept of the brain-to-brain loop for laboratory testing. In this concept, in the brain of the physician caring for the patient, the first step involves the selection of laboratory tests and the final step is the transmission of the test result to the ordering physician. There are many intermediary steps, some of which are preanalytic, ie, before performance of the test; some are analytic and relate to the actual performance of the test; and others are postanalytic and involve transmission of test results into the medical record. The introduction of this concept led to a system to identify and classify errors associated with laboratory test performance. Errors have since been considered as preanalytic, analytic, and postanalytic. During the past 4 decades, changes in medical practice have significantly altered the brain-to-brain loop for laboratory testing. This review describes the changes and their implications for analysis of errors associated with laboratory testing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1309/ajcpr28hwhssdnon

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Research works printed but not linked: 32

  1. Lundberg, 1981, Acting on significant laboratory results [editorial], JAMA, 245, 1762, 10.1001/jama.1981.03310420052033 · DOI · Paper page
  2. Lundberg, 1998, The need for an outcomes research agenda for clinical laboratory testing [editorial], JAMA, 280, 565, 10.1001/jama.280.6.565 · DOI
  3. Hemmelgarn, 2010, Nephrology visits and health care resource use before and after reporting estimated glomerular filtration rate, JAMA, 303, 1151, 10.1001/jama.2010.303 · DOI · Paper page
  4. Noble, 2008, The impact of automated eGFR reporting and education on nephrology service referrals, Nephrol Dial Transplant, 23, 3845, 10.1093/ndt/gfn385 · DOI
  5. Neumann, 2010, Medicare and medical technology: the growing demand for relevant outcomes, N Engl J Med, 362, 377, 10.1056/NEJMp0912062 · DOI
  6. Plebani, 1999, The changing face of clinical laboratories, Clin Chem Lab Med, 37, 711, 10.1515/CCLM.1999.109 · DOI
  7. Plebani, 2002, Charting the course of medical laboratories in a changing environment, Clin Chim Acta, 319, 87, 10.1016/S0009-8981(02)00028-1 · DOI
  8. Plebani, 2010, Is laboratory medicine a dying profession? Blessed are those who have not seen and yet have believed [editorial], Clin Biochem, 43, 939, 10.1016/j.clinbiochem.2010.05.015 · DOI
  9. Walley, 2008, Evaluating laboratory diagnostic tests [editorial], BMJ, 336, 569, 10.1136/bmj.39513.576701.80 · DOI
  10. Plebani, 1997, Mistakes in a stat laboratory: types and frequency, Clin Chem, 43, 1348, 10.1093/clinchem/43.8.1348 · DOI · Paper page
  11. Carraro, 2007, Errors in a stat laboratory: types and frequencies 10 years later, Clin Chem, 53, 1338, 10.1373/clinchem.2007.088344 · DOI · Paper page
  12. Plebani, 2006, Errors in clinical laboratories or errors in laboratory medicine?, Clin Chem Lab Med, 44, 750, 10.1515/CCLM.2006.123 · DOI · Paper page
  13. Plebani, 2007, Errors in laboratory medicine and patient safety: the road ahead, Clin Chem Lab Med, 45, 700, 10.1515/CCLM.2007.170 · DOI · Paper page
  14. Plebani, 2009, Exploring the iceberg of errors in laboratory medicine, Clin Chim Acta, 404, 16, 10.1016/j.cca.2009.03.022 · DOI · Paper page
  15. Plebani, 2010, The detection and prevention of errors in laboratory medicine, Ann Clin Biochem, 47, 101, 10.1258/acb.2009.009222 · DOI · Paper page
  16. Holman, 2002, Evaluation of an automatic pre-analytical robotic workstation at two academic health centers, Clin Chem, 48, 540, 10.1093/clinchem/48.3.540 · doi:10.1093/clinchem/48.3.540
  17. Da Rin, 2009, Pre-analytical workstations: a tool for reducing laboratory errors, Clin Chim Acta, 404, 68, 10.1016/j.cca.2009.03.024 · DOI · Paper page
  18. Piva, 2009, Evaluation of effectiveness of a computerized notification system for reporting critical values, Am J Clin Pathol, 131, 432, 10.1309/AJCPYS80BUCBXTUH · DOI
  19. Norman, 2010, Diagnostic error and clinical reasoning, Med Educ, 44, 94, 10.1111/j.1365-2923.2009.03507.x · DOI · Paper page
  20. Laposata, 2007, “Pre-pre” and “post-post” analytical error: high-incidence patient safety hazards involving the clinical laboratory, Clin Chem Lab Med, 45, 712, 10.1515/CCLM.2007.173 · DOI · Paper page
  21. Plebani, 2009, Interpretative commenting: a tool for improving the laboratory-clinical interface, Clin Chim Acta, 404, 46, 10.1016/j.cca.2009.03.012 · DOI
  22. Wahls, 2007, The frequency of missed test results and associated treatment delays in a highly computerized health system, BMC Fam Pract, 8, 32, 10.1186/1471-2296-8-32 · DOI
  23. Kachalia, 2007, Missed and delayed diagnoses in the emergency department: a study of closed malpractice claims from 4 liability insurers, Ann Emerg Med, 49, 196, 10.1016/j.annemergmed.2006.06.035 · DOI · Paper page
  24. Soloway, 1990, Commentary: patient initiated laboratory testing: applauding the inevitable, JAMA, 264, 1718, 10.1001/jama.1990.03450130090033 · doi:10.1001/jama.1990.03450130090033
  25. Nichols, 2003, Quality in point-of-care testing, Expert Rev Mol Diagn, 3, 563, 10.1586/14737159.3.5.563 · DOI
  26. Ehrmeyer, 2007, Point-of-care testing, medical error, and patient safety: a 2007 assessment, Clin Chem Lab Med, 45, 766, 10.1515/CCLM.2007.164 · DOI
  27. Zaninotto, 2010, The “hospital central laboratory”: automation, integration and clinical usefulness, Clin Chem Lab Med, 48, 911, 10.1515/CCLM.2010.192 · DOI
  28. Sciacovelli, 2011, Quality indicators in laboratory medicine: from theory to practice: preliminary data from the IFCC Working Group Project “Laboratory Errors and Patient Safety” published online ahead of print February 23, 2011], Clin Chem Lab Med, 49, 835, 10.1515/CCLM.2011.128 · DOI
  29. Carden, 2009, An examination of the supply and demand for clinical laboratory professionals in the United States, Transfusion, 49, 2520, 10.1111/j.1537-2995.2009.02469.x · doi:10.1111/j.1537-2995.2009.02469.x
  30. Smith, 2010, Educating medical students in laboratory medicine, Am J Clin Pathol, 133, 533, 10.1309/AJCPQCT94SFERLNI · DOI
  31. Jones, 2002, Perception on how well graduates are prepared for the role of pre-registration house officer: a comparison of outcomes from a traditional and an integrated PBL curriculum, Med Educ, 36, 16, 10.1046/j.1365-2923.2002.01105.x · DOI · Paper page
  32. Kon, 2010, The shared decision-making continuum, JAMA, 304, 903, 10.1001/jama.2010.1208 · DOI · Paper page

Cited by

See all 212

Metadata

Authors
Plebani, M., Laposata, M., & Lundberg, G. D.
Venue
American Journal of Clinical Pathology
Published
2011-12-01
Volume
136
Issue
6
Pages
829-833
ISSN
  • 0002-9173 (ISSN-L)
  • 1943-7722
OpenAlex
W2063825062
Cited by
212
References
6
FWCI
7.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Brain-to-Brain Loop Concept for Laboratory Testing 40 Years After Its Introduction. https://app.cochat.ai/papers/10.1309/ajcpr28hwhssdnon
The paper
Plebani, M., Laposata, M., & Lundberg, G. D. (2011). The Brain-to-Brain Loop Concept for Laboratory Testing 40 Years After Its Introduction. American Journal of Clinical Pathology. https://doi.org/10.1309/ajcpr28hwhssdnon

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.