Order of blood draw: Opinion Paper by the European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for the Preanalytical Phase (WG-PRE)
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
It has been well reported over recent years that most errors within the total testing process occur in the pre-analytical phase (46%–68.2%), an area that is usually outside of the direct control of the laboratory and which includes sample collection (phlebotomy). National and international (WHO, CLSI) guidelines recommend that the order of draw of blood during phlebotomy should be blood culture/sterile tubes, then plain tubes/gel tubes, then tubes containing additives. This prevents contamination of sample tubes with additives from previous tubes that could cause erroneous results. There have been a number of studies recently looking at whether order of draw remains a problem with modern phlebotomy techniques and materials, or it is an outdated practice followed simply because of historical reasons. In the following article, the European Federation of Clinical Chemistry and Laboratory Medicine Working Group for the Preanalytical Phase (EFLM WG-PRE) provides an overview and summary of the literature with regards to order of draw in venous blood collection. Given the evidence presented in this article, the EFLM WG-PRE herein concludes that a significant frequency of sample contamination does occur if order of draw is not followed during blood collection and when performing venipuncture under less than ideal circumstances, thus putting patient safety at risk. Moreover, given that order of draw is not difficult to follow and knowing that ideal phlebotomy conditions and protocols are not always followed or possible, EFLM WG-PRE supports the continued recommendation of ensuring a correct order of draw for venous blood collection.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Errors in a Stat Laboratory: Types and Frequencies 10 Years Later
Carraro, P., & Plebani, M. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.088344 · Cited by 670
Mistakes in a stat laboratory: types and frequency
Plebani, M., & Carraro, P. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.8.1348 · Cited by 572
The Brain-to-Brain Loop Concept for Laboratory Testing 40 Years After Its Introduction
Plebani, M., Laposata, M., & Lundberg, G. D. (2011) · American Journal of Clinical Pathology · doi:10.1309/ajcpr28hwhssdnon · Cited by 212
Medical errors: impact on clinical laboratories and other critical areas
Kalra, J. (2004) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.08.009 · Cited by 168
Quantitative Chemical Analysis
Li, N., Hefferren, J. J., & Li, K. (2012) · WORLD SCIENTIFIC eBooks · doi:10.1142/8727 · Cited by 101
Simundic, A.-M., Church, S., Cornes, M. P., Grankvist, K., Lippi, G., Nybo, M., Nikolac, N., van Dongen-Lases, E., Eker, P., Kovalevskaya, S., et al. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-1053 · Cited by 95
Self-citationSpurious hyperkalaemia due to EDTA contamination: common and not always easy to identify
Cornes, M. P., Ford, C., & Gama, R. (2008) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2008.007241 · Cited by 69
Self-citationSharratt, C. L., Gilbert, C. J., Cornes, M. C., Ford, C., & Gama, R. (2009) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2008.01981.x · Cited by 66 · cited 1×
“The first measured EDTA levels in all hyperkalaemic samples and the second measured EDTA in all hypomagnesaemic, hypocalcaemic and hypozincaenic samples over a 1 month period [21, 22].”
BackgroundSelf-citationRecommended "order of draw" for collecting blood specimens into additive-containing tubes.
Calam, R. R., & Cooper, M. H. (1982) · Clinical Chemistry · doi:10.1093/clinchem/28.6.1399 · Cited by 47
The order of draw: myth or science?
Salvagno, G., Lima-Oliveira, G., Brocco, G., Danese, E., Guidi, G. C., & Lippi, G. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0412 · Cited by 42
Self-citation
Cited by
Joint EFLM-COLABIOCLI Recommendation for venous blood sampling
Simundic, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimaraes, J. T., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0602 · Cited by 240
Self-citationPre-analytical issues in the haemostasis laboratory: guidance for the clinical laboratories
Magnette, A., Chatelain, M., Chatelain, B., Ten Cate, H., & Mullier, F. (2016) · Thrombosis Journal · doi:10.1186/s12959-016-0123-z · Cited by 166
Lippi, G., von Meyer, A., Cadamuro, J., & Simundic, A.-M. (2019) · Diagnosis · doi:10.1515/dx-2018-0018 · Cited by 135
Self-citationLima-Oliveira, G., Volanski, W., Lippi, G., Picheth, G., & Guidi, G. C. (2017) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2017.1295317 · Cited by 117
Self-citationBlood venous sample collection: Recommendations overview and a checklist to improve quality
Giavarina, D., & Lippi, G. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.02.021 · Cited by 136
Self-citation
Metadata
- Authors
- Cornes, M., van Dongen-Lases, E., Grankvist, K., Ibarz, M., Kristensen, G., Lippi, G., Nybo, M., & Simundic, A.-M.
- Affiliations
- The Royal Wolverhampton NHS Trust (GB)
- Department of Clinical Chemistry, Academic Medical Center, Amsterdam, The Netherlands
- Umeå University (SE)
- Laboratori Clínic Hospital Arnau de Vilanova, Lleida, Spain
- Norwegian Clinical Chemistry EQA Programme, Bergen, Norway
- University of Verona (IT)
- Odense University Hospital (DK)
- Department of Medical Laboratory Diagnostics, University Hospital Sveti Duh, Zagreb, Croatia
- Corresponding author
- Cornes, Michael
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2016-07-21
- Volume
- 55
- Issue
- 1
- Pages
- 27-31
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2479249860
- Semantic Scholar
- 2691ae319d1d8efc628f2da25f083605b574000a
- Cited by
- 92
- References
- 23
- Citations by year
- 2026: 5 · 2025: 5 · 2024: 5 · 2023: 7 · 2022: 21 · 2021: 8 · 2020: 6 · 2019: 14 · 2018: 9 · 2017: 10 · 2016: 2
- FWCI
- 9.39
- Type
- journal article
- Language
- en
- Open access
- Licence
- other-oa
- Locations
- Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- University of Southern Denmark Research Portal (University of Southern Denmark) (submittedVersion, other-oa)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
- Keywords
- pre-analytical phase, phlebotomy, venipuncture, sample contamination, additive interference, patient safety, laboratory errors
- MeSH terms
- Europe, Humans, Phlebotomy, Clinical Chemistry Tests
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Order of blood draw: Opinion Paper by the European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for the Preanalytical Phase (WG-PRE). https://app.cochat.ai/papers/10.1515/cclm-2016-0426
- The paper
- Cornes, M., van Dongen-Lases, E., Grankvist, K., Ibarz, M., Kristensen, G., Lippi, G., Nybo, M., & Simundic, A.-M. (2017). Order of blood draw: Opinion Paper by the European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for the Preanalytical Phase (WG-PRE). Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2016-0426
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.