Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 470

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Finite Element Analysis Based on In Vivo HR-pQCT Images of the Distal Radius Is Associated With Wrist Fracture in Postmenopausal Women

Boutroy, Stephanie, Van Rietbergen, Bert, Sornay-Rendu, Elisabeth, Munoz, Francoise, Bouxsein, Mary L, Delmas, Pierre D·2008·Journal of Bone and Mineral Research

Abstract

BMD, bone microarchitecture, and bone mechanical properties assessed in vivo by finite element analysis were associated with wrist fracture in postmenopausal women. Introduction: Many fractures occur in individuals with normal BMD. Assessment of bone mechanical properties by finite element analysis (FEA) may improve identification of those at high risk for fracture. Materials and Methods: We used HR-pQCT to assess volumetric bone density, microarchitecture, and μFE-derived bone mechanical properties at the radius in 33 postmenopausal women with a prior history of fragility wrist fracture and 33 age-matched controls from the OFELY cohort. Radius areal BMD (aBMD) was also measured by DXA. Associations between density, microarchitecture, mechanical parameters and fracture status were evaluated by univariate logistic regression analysis and expressed as ORs (with 95% CIs) per SD change. We also conducted a principal components (PCs) analysis (PCA) to reduce the number of parameters and study their association (OR) with wrist fracture. Results: Areal and volumetric densities, cortical thickness, trabecular number, and mechanical parameters such as estimated failure load, stiffness, and the proportion of load carried by the trabecular bone at the distal and proximal sites were associated with wrist fracture (p < 0.05). The PCA revealed five independent components that jointly explained 86.2% of the total variability of bone characteristics. The first PC included FE-estimated failure load, areal and volumetric BMD, and cortical thickness, explaining 51% of the variance with an OR for wrist fracture = 2.49 (95% CI, 1.32–4.72). Remaining PCs did not include any density parameters. The second PC included trabecular architecture, explaining 12% of the variance, with an OR = 1.82 (95% CI, 0.94–3.52). The third PC included the proportion of the load carried by cortical versus trabecular bone, assessed by FEA, explaining 9% of the variance, and had an OR = 1.61 (95% CI, 0.94–2.77). Thus, the proportion of load carried by cortical versus trabecular bone seems to be associated with wrist fracture independently of BMD and microarchitecture (included in the first and second PC, respectively). Conclusions: These results suggest that bone mechanical properties assessed by μFE may provide information about skeletal fragility and fracture risk not assessed by BMD or architecture measurements alone and are therefore likely to enhance the prediction of wrist fracture risk.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1359/jbmr.071108

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 470

Metadata

Authors
Boutroy, S., Van Rietbergen, B., Sornay-Rendu, E., Munoz, F., Bouxsein, M. L., & Delmas, P. D.
Venue
Journal of Bone and Mineral Research
Published
2008-03-01
Volume
23
Issue
3
Pages
392-399
ISSN
  • 0884-0431 (ISSN-L)
  • 1523-4681
OpenAlex
W1976387068
Cited by
470
References
28
FWCI
23.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Finite Element Analysis Based on In Vivo HR-pQCT Images of the Distal Radius Is Associated With Wrist Fracture in Postmenopausal Women. https://app.cochat.ai/papers/10.1359/jbmr.071108
The paper
Boutroy, S., Van Rietbergen, B., Sornay-Rendu, E., Munoz, F., Bouxsein, M. L., & Delmas, P. D. (2008). Finite Element Analysis Based on In Vivo HR-pQCT Images of the Distal Radius Is Associated With Wrist Fracture in Postmenopausal Women. Journal of Bone and Mineral Research. https://doi.org/10.1359/jbmr.071108

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.