The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Light transport in tissue
Abstract
The propagation of light in tissue may be calculated by exact transport theory, or the approximate diffusion theory, provided the optical properties are known at the source wavelength. Optical properties for the exact methods are the absorption coefficient, scattering coefficient, and angular distribution of scattering. Appropriate properties for diffusion theory are the diffusion length and diffusion coefficient (corrected for anisotropic scattering). Computer programs and analytical solutions (for some simple geometries) exist, but the optical properties have to be determined experimentally and are not well defined as yet. The radiant energy fluence rate and the diffuse transmittance and reflectance have been measured in several tissues and in a few geometries, but there are gaps in the data as a function of wavelength. Calculations and measurements reveal that very large errors can result if the optical properties (for example, the diffusion length) are inaccurate, if anisotropic scattering is neglected, or if the finite size of the irradiating light beam is not taken into account. Furthermore, the radiant energy fluence and transmittance are perturbed by local regions of lesser or greater absorption, although recovery of the fluence and transmittance occurs beyond some three diffusion lengths.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Table of Integrals, Series, and Products
(1980) · Elsevier eBooks · doi:10.1016/c2013-0-10754-4 · Cited by 18,782
Data Reduction and Error Analysis for the Physical Sciences
Bevington, P. R., Robinson, D. K., Blair, J. M., Mallinckrodt, A. J., & McKay, S. (1993) · Computers in Physics · doi:10.1063/1.4823194 · Cited by 14,824
Methods of Theoretical Physics
Morse, P. M., Feshbach, H., & Hill, E. L. (1954) · American Journal of Physics · doi:10.1119/1.1933765 · Cited by 13,197
Chandrasekhar, S. (1950) · CERN Document Server (European Organization for Nuclear Research) · Cited by 8,702
Metropolis, N., & Ulam, S. (1949) · Journal of the American Statistical Association · doi:10.1080/01621459.1949.10483310 · Cited by 6,474
Computer methods for mathematical computations
Forsythe, G. E., Malcolm, M. A., & Moler, C. (1977) · UCLA Biblioteca de Ingenieria Civil · Cited by 2,683
Light scattering in planetary atmospheres
Hansen, J. E., & Travis, L. D. (1974) · Space Science Reviews · doi:10.1007/bf00168069 · Cited by 2,624
Case, K. M., Zweifel, P. F., & Pomraning, G. C. (1968) · Physics Today · doi:10.1063/1.3034554 · Cited by 1,609
An Introduction to Atmospheric Radiation
Liou, K. N., & Bohren, C. F. (1981) · Physics Today · doi:10.1063/1.2914664 · Cited by 1,289
The Delta-Eddington Approximation for Radiative Flux Transfer
Joseph, J. H., Wiscombe, W. J., & Weinman, J. A. (1976) · Journal of the Atmospheric Sciences · doi:10.1175/1520-0469(1976)033<2452:tdeafr>2.0.co;2 · Cited by 1,080
Cited by
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Bashkatov, A. N., Genina, E. A., Kochubey, V. I., & Tuchin, V. V. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/004 · Cited by 1,720
Optical Properties of Circulating Human Blood in the Wavelength Range 400–2500 nm
Roggan, A., Friebel, M., Dörschel, K., Hahn, A., & Müller, G. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429919 · Cited by 819
OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW
BASHKATOV, A. N., GENINA, E. A., & TUCHIN, V. V. (2011) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545811001319 · Cited by 761
Simpson, C. R., Kohl, M., Essenpreis, M., & Cope, M. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/9/003 · Cited by 651
A Monte Carlo model of light propagation in tissue
Prahl, S. A. (1989) · SPIE Proceedings · doi:10.1117/12.2283590 · Cited by 616
Salomatina, E. V., Jiang, B., Novak, J., & Yaroslavsky, A. N. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2398928 · Cited by 599
Measurement of the penetration depths of red and near infrared light in human “ex vivo” tissues
Stolik, S., Delgado, J. A., Pérez, A., & Anasagasti, L. (2000) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/s1011-1344(00)00082-8 · Cited by 468
Optical properties of human skin
Lister, T., Wright, P. A., & Chappell, P. H. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.9.090901 · Cited by 467
“However, only the earlier studies analyzed here, those which produced higher values of reduced-scattering coefficient, submerged the sample in water or saline.(55,75) Salomatina et al.”
BackgroundInfluentialCorrigendum: Optical properties of biological tissues: a review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/14/5007 · Cited by 430
Reversible Spatiotemporal Control of Induced Protein Degradation by Bistable PhotoPROTACs
Pfaff, P., Samarasinghe, K. T. G., Crews, C. M., & Carreira, E. M. (2019) · ACS Central Science · doi:10.1021/acscentsci.9b00713 · Cited by 301
Strangman, G. E., Li, Z., & Zhang, Q. (2013) · PLoS ONE · doi:10.1371/journal.pone.0066319 · Cited by 262
Metadata
- Authors
- Profio, A. E.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1989-06-15
- Volume
- 28
- Issue
- 12
- Pages
- 2216
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2008695134
- Cited by
- 305
- References
- 26
- FWCI
- 7.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.