The DOI matches its Crossref record.
Analysis of confocal laser-microscope optics for 3-D fluorescence correlation spectroscopy
Abstract
Quantitative fluorescence correlation spectroscopy (FCS) and fluorescence photobleaching recovery (FPR) measurements in bulk solution require a well characterized confocal laser microscope optical system. The introduction of a characteristic function, the collection efficiency function (CEF), provides a quantitative theoretical analysis of this system, which yields an interpretation of the FCS and FPR measurements in three dimensions. We demonstrate that when the proper field diaphragm is introduced, the 3-D FCS measurements can be mimicked by a 2-D theory with only minor error. The FPR characteristic recovery time for diffusion is expected to be slightly longer than the corresponding time measured by FCS in the same conditions. This is because the profile of the laser beam used for photobleaching is not affected by the field diaphragm. The CEF is also important for quantitative analysis of standard scanning confocal microscopy when it is carried out using a finite detection pinhole.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rigler, R., Mets, �., Widengren, J., & Kask, P. (1993) · European Biophysics Journal · doi:10.1007/bf00185777 · Cited by 1,002
Schwille, P., Meyer-Almes, F. J., & Rigler, R. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78833-7 · Cited by 817
Schwille, P., Haupts, U., Maiti, S., & Webb, W. W. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77065-7 · Cited by 722
The Photon Counting Histogram in Fluorescence Fluctuation Spectroscopy
Chen, Y., Müller, J. D., So, P. T. C., & Gratton, E. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)76912-2 · Cited by 682
Biological and Chemical Applications of Fluorescence Correlation Spectroscopy: A Review
Hess, S. T., Huang, S., Heikal, A. A., & Webb, W. W. (2002) · Biochemistry · doi:10.1021/bi0118512 · Cited by 653
Effenhauser, C. S., Bruin, G. J. M., Paulus, A., & Ehrat, M. (1997) · Analytical Chemistry · doi:10.1021/ac9703919 · Cited by 640
Probing Individual Molecules with Confocal Fluorescence Microscopy
Nie, S., Chiu, D. T., & Zare, R. N. (1994) · Science · doi:10.1126/science.7973650 · Cited by 549
Wachsmuth, M., Waldeck, W., & Langowski, J. (2000) · Journal of Molecular Biology · doi:10.1006/jmbi.2000.3692 · Cited by 455
Fluorescence Correlation Spectroscopy: Past, Present, Future
Elson, E. L. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2011.11.012 · Cited by 438
Self-citationFocal Volume Optics and Experimental Artifacts in Confocal Fluorescence Correlation Spectroscopy
Hess, S. T., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)73990-8 · Cited by 394
Fluorescence Correlation Spectroscopy and Its Potential for Intracellular Applications
Schwille, P. (2001) · Cell Biochemistry and Biophysics · doi:10.1385/cbb:34:3:383 · Cited by 367
Dertinger, T., Pacheco, V., von der Hocht, I., Hartmann, R., Gregor, I., & Enderlein, J. (2007) · ChemPhysChem · doi:10.1002/cphc.200600638 · Cited by 345
Fluorescence correlation spectroscopy: Diagnostics for sparse molecules
Maiti, S., Haupts, U., & Webb, W. W. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.22.11753 · Cited by 317
The Standard Deviation in Fluorescence Correlation Spectroscopy
Wohland, T., Rigler, R., & Vogel, H. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76264-9 · Cited by 273
Metadata
- Authors
- Qian, H., & Elson, E. L.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1991-04-01
- Volume
- 30
- Issue
- 10
- Pages
- 1185
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2114370655
- Cited by
- 192
- References
- 0
- FWCI
- 2.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.