Influence of particle size and concentration on the diffuse backscattering of polarized light from tissue phantoms and biological cell suspensions
The DOI matches its Crossref record.
Abstract
We present experimental results that show the spatial variations of the diffuse-backscattered intensity when linearly polarized light is incident upon highly scattering media. Experiments on polystyrene-sphere and Intralipid suspensions demonstrate that the radial and azimuthal variations of the observed pattern depend on the concentration, size, and anisotropy factor g of the particles that constitute the scattering medium. Measurements performed on biological-cell suspensions show the potential of this method for cell characterization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Imaging skin pathology with polarized light
Jacques, S. L., Ramella-Roman, J. C., & Lee, K. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1484498 · Cited by 582
A review of in‐vivo optical properties of human tissues and its impact on PDT
Sandell, J. L., & Zhu, T. C. (2011) · Journal of Biophotonics · doi:10.1002/jbio.201100062 · Cited by 384
Polarized light interaction with tissues
Tuchin, V. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.071114 · Cited by 384
“As we already discussed, when incident circular polarized light is multiply scattered, it is depolarized with the depolarization rate depending on the size and shape of scattering particles, 54,58,147 and on the number of scattering events (see Fig.”
BackgroundImaging superficial tissues with polarized light
Jacques, S. L., Roman, J. R., & Lee, K. (2000) · Lasers in Surgery and Medicine · doi:10.1002/(sici)1096-9101(2000)26:2<119::aid-lsm3>3.0.co;2-y · Cited by 366
Propagation of polarized light in birefringent turbid media: A Monte Carlo study
Wang, X., & Wang, L. V. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1483315 · Cited by 270
Kunnen, B., Macdonald, C., Doronin, A., Jacques, S., Eccles, M., & Meglinski, I. (2015) · Journal of Biophotonics · doi:10.1002/jbio.201400104 · Cited by 261
Pierangelo, A., Manhas, S., Benali, A., Fallet, C., Totobenazara, J.-L., Antonelli, M.-R., Novikova, T., Gayet, B., De Martino, A., & Validire, P. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.4.046014 · Cited by 195
Diffuse backscattering Mueller matricesof highly scattering media
Hielscher, A., Eick, A., Mourant, J., Shen, D., Freyer, J., & Bigio, I. (1997) · Optics Express · doi:10.1364/oe.1.000441 · Cited by 183
“[ 6,12] Approximately 30 ml of each suspension was used for the backscattering experiments.”
MethodSelf-citationEmerging biomedical sensing technologies and their applications
Cote, G. L., Lec, R. M., & Pishko, M. V. (2003) · IEEE Sensors Journal · doi:10.1109/jsen.2003.814656 · Cited by 180
“to be able differentiate between cancer versus normal fibroblast cellsin vitro [76].”
BackgroundMueller matrix decomposition for polarized light assessment of biological tissues
Ghosh, N., Wood, M. F. G., Li, S., Weisel, R. D., Wilson, B. C., Li, R., & Vitkin, I. A. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200810040 · Cited by 166
Metadata
- Authors
- Hielscher, A. H., Mourant, J. R., & Bigio, I. J.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1997-01-01
- Volume
- 36
- Issue
- 1
- Pages
- 125
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2067981767
- Cited by
- 228
- References
- 0
- FWCI
- 11.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.