The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Multicomponent blood analysis by near-infrared Raman spectroscopy
Abstract
We demonstrate the use of Raman spectroscopy to measure the concentration of many important constituents (analytes) in serum and whole blood samples at physiological concentration in vitro across a multipatient data set. A near-infrared (830-nm) diode laser generates Raman spectra that contain superpositions of Raman signals from different analytes. Calibrations for glucose, cholesterol, urea, and other analytes are developed by use of partial least-squares cross validation. We predict six analytes in serum with significant accuracy in a 66-patient data set, using 60-s spectra. The calibrations are shown to be fairly robust against system drift over the span of seven weeks. In whole blood, a preliminary analysis yields accurate predictions of some of the same analytes and also hematocrit. The results hold promise for potential medical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Partial least-squares regression: a tutorial
Geladi, P., & Kowalski, B. R. (1986) · Analytica Chimica Acta · doi:10.1016/0003-2670(86)80028-9 · Cited by 6,992
Haaland, D. M., & Thomas, E. V. (1988) · Analytical Chemistry · doi:10.1021/ac00162a020 · Cited by 2,539
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Maier, J. S., Walker, S. A., Fantini, S., Franceschini, M. A., & Gratton, E. (1994) · Optics Letters · doi:10.1364/ol.19.002062 · Cited by 318
Noninvasive Glucose Monitoring in Diabetic Patients: A Preliminary Evaluation
Robinson, M. R., Eaton, R. P., Haaland, D. M., Koepp, G. W., Thomas, E. V., Stallard, B. R., & Robinson, P. L. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.9.1618 · Cited by 284
Marbach, R., Koschinsky, T., Gries, F. A., & Heise, H. M. (1993) · Applied Spectroscopy · doi:10.1366/0003702934415354 · Cited by 164
Influence of glucose concentration on light scattering in tissue-simulating phantoms
Kohl, M., Essenpreis, M., Böcker, D., & Cope, M. (1994) · Optics Letters · doi:10.1364/ol.19.002170 · Cited by 158
Noninvasive optical polarimetric glucose sensing using a true phase measurement technique
Cote, G. L., Fox, M. D., & Northrop, R. B. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.142650 · Cited by 158
Bruulsema, J. T., Hayward, J. E., Farrell, T. J., Patterson, M. S., Heinemann, L., Berger, M., Koschinsky, T., Sandahl-Christiansen, J., Ørskov, H., Essenpreis, M., et al. (1997) · Optics Letters · doi:10.1364/ol.22.000190 · Cited by 156
Feasibility of measuring blood glucose concentration by near-infrared Raman spectroscopy
Berger, A. J., Itzkan, I., & Feld, M. S. (1997) · Spectrochimica Acta Part A Molecular Spectroscopy · doi:10.1016/s1386-1425(96)01779-9 · Cited by 149
Self-citationArnold, M. A., & Small, G. W. (1990) · Analytical Chemistry · doi:10.1021/ac00213a021 · Cited by 142
An Enhanced Algorithm for Linear Multivariate Calibration
Berger, A. J., Koo, T.-W., Itzkan, I., & Feld, M. S. (1998) · Analytical Chemistry · doi:10.1021/ac970721p · Cited by 119
Self-citationNoninvasive glucose sensing utilizing a digital closed-loop polarimetric approach
Cameron, B. D., & Cote, G. L. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.649993 · Cited by 113
Tensorial calibration: I. First‐order calibration
Sanchez, E., & Kowalski, B. R. (1988) · Journal of Chemometrics · doi:10.1002/cem.1180020404 · Cited by 105
Heise, H. M., Marbach, R., Koschinsky, T., & Gries, F. A. (1994) · Applied Spectroscopy · doi:10.1366/0003702944027598 · Cited by 105
Application of a multivariate technique to Raman spectra for quantification of body chemicals
Goetz, M. J., Coté, G. L., Erckens, R. J., March, W. F., & Motamedi, M. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.391172 · Cited by 102
Reagentless Near-Infrared Determination of Glucose in Whole Blood Using Multivariate Calibration
Haaland, D. M., Robinson, M., Koepp, G. W., Thomas, E. V., & Eaton, R. P. (1992) · Applied Spectroscopy · doi:10.1366/000370292789619232 · Cited by 99
Multispectral polarimetric glucose detection using a single Pockels cell
King, T. W., Coté, G. L., McNichols, R. J., & Goetz, M. J. (1994) · Optical Engineering · doi:10.1117/12.173556 · Cited by 83
Berger, A. J., Wang, Y., & Feld, M. S. (1996) · Applied Optics · doi:10.1364/ao.35.000209 · Cited by 83
Self-citationBudı́nová, G., Salva, J., & Volka, K. (1997) · Applied Spectroscopy · doi:10.1366/0003702971941034 · Cited by 82
Analysis of metabolites in aqueous solutions by using laser Raman spectroscopy
Wang, S. Y., Hasty, C. E., Watson, P. A., Wicksted, J. P., Stith, R. D., & March, W. F. (1993) · Applied Optics · doi:10.1364/ao.32.000925 · Cited by 71
Jagemann, K.-U., Fischbacher, C., Danzer, K., Müller, U., & Mertes, B. (1995) · Zeitschrift für Physikalische Chemie · doi:10.1524/zpch.1995.191.part_2.179 · Cited by 55
Dou, X., Yamaguchi, Y., Yamamoto, H., Doi, S., & Ozaki, Y. (1996) · Vibrational Spectroscopy · doi:10.1016/0924-2031(96)00036-7 · Cited by 49
Ham, F. M., Kostanic, I. N., Cohen, G. M., et al. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.581938 · Cited by 49
Wicksted, J. P., Erckens, R. J., Motamedi, M., & March, W. F. (1995) · Applied Spectroscopy · doi:10.1366/0003702953964912 · Cited by 46
Erckens, R. J., Motamedi, M., March, W. F., & Wicksted, J. P. (1997) · Journal of Raman Spectroscopy · doi:10.1002/(sici)1097-4555(199705)28:5<293::aid-jrs47>3.0.co;2-0 · Cited by 45
Dou, X., Yamaguchi, Y., Yamamoto, H., Uenoyama, H., & Ozaki, Y. (1996) · Applied Spectroscopy · doi:10.1366/0003702963905042 · Cited by 43
Spanner, G., & Nießner, R. (1996) · Analytical and Bioanalytical Chemistry · doi:10.1007/s0021663550327 · Cited by 38
How Physicians Use Laboratory Tests
Skendzel, L. P. (1978) · JAMA · doi:10.1001/jama.1978.03280380077027 · Cited by 34
Dou, X., Yamaguchi, Y., Yamamoto, H., Doi, S., & Ozaki, Y. (1997) · Vibrational Spectroscopy · doi:10.1016/s0924-2031(97)00008-8 · Cited by 17
Tarr, R. V. (1991) · UPT. Syiah Kuala University Library (Syiah Kuala University) · Cited by 16
Cited by
Prospects for in vivo Raman spectroscopy
Hanlon, E. B., Manoharan, R., Koo, T.-W., Shafer, K. E., Motz, J. T., Fitzmaurice, M., Kramer, J. R., Itzkan, I., Dasari, R. R., & Feld, M. S. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/201 · Cited by 894
Self-citationFluorescence Spectroscopy In Vivo
Ramanujam, N. (2000) · Encyclopedia of Analytical Chemistry · doi:10.1002/9780470027318.a0102 · Cited by 508
Feng, S., Chen, R., Lin, J., Pan, J., Chen, G., Li, Y., Cheng, M., Huang, Z., Chen, J., & Zeng, H. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.03.033 · Cited by 450
Combined In Vivo Confocal Raman Spectroscopy and Confocal Microscopy of Human Skin
Caspers, P. J., Lucassen, G. W., & Puppels, G. J. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74501-9 · Cited by 446
Quantitative Analysis Using Raman Spectrometry
Pelletier, M. J. (2003) · Applied Spectroscopy · doi:10.1366/000370203321165133 · Cited by 435
Metadata
- Authors
- Berger, A. J., Koo, T.-W., Itzkan, I., Horowitz, G., & Feld, M. S.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1999-05-01
- Volume
- 38
- Issue
- 13
- Pages
- 2916
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2018794807
- Cited by
- 255
- References
- 31
- FWCI
- 6.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.