Cited by 95Advanced Semiconductor Detectors and MaterialsAdvanced Optical Sensing TechnologiesPhotocathodes and Microchannel Plates

Single-photon counting for the 1300–1600-nm range by use of Peltier-cooled and passively quenched InGaAs avalanche photodiodes

Rarity, John G., Wall, Thomas E., Ridley, Kevin D., Owens, Philippa C. M., Tapster, Paul R.·2000·Applied Optics

Abstract

We evaluate the performance of various commercially available InGaAs/InP avalanche photodiodes for photon counting in the infrared at temperatures that can be reached by Peltier cooling. We find that dark count rates are high, and this can partially saturate devices before optimum performance is achieved. At low temperatures the dark count rate rises because of a strong contribution from correlated afterpulses. We discuss ways of suppressing these afterpulses for different photon-counting applications.

Integrity signals

Registry

Crossref · 10.1364/ao.39.006746

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Photon-counting devices based on III-V semiconductors are now available in the near-infrared window.

    “Photon-counting devices based on III-V semiconductors now become available in the near-IR window (Hiskett et al 2000, Rarity et al 2000, Stucki et al 2001).”

    From Single-photon sources (2005) · cites this paper as Rarity et al 2000

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Rarity, J. G., Wall, T. E., Ridley, K. D., Owens, P. C. M., & Tapster, P. R.
Venue
Applied Optics
Published
2000-12-20
Volume
39
Issue
36
Pages
6746
ISSN
  • 0003-6935 (ISSN-L)
  • 1539-4522
OpenAlex
W1980602780
Cited by
95
References
12
Citations by year
2026: 1 · 2024: 5 · 2023: 2 · 2022: 1 · 2021: 1 · 2020: 3 · 2019: 1 · 2018: 3 · 2017: 5 · 2016: 4 · 2015: 3 · 2014: 3 · 2013: 1 · 2012: 4
FWCI
5.19
Type
journal article
Language
en
Open access
closed
Locations
  • Applied Optics (publishedVersion)
  • PubMed (publishedVersion)
  • UCL Discovery (University College London) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Semiconductor Detectors and Materials
  • Physical Sciences › Physics and Astronomy › Instrumentation › Advanced Optical Sensing Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Photocathodes and Microchannel Plates
Keywords
single photon counting, InGaAs avalanche photodiode, infrared photon detection, Peltier cooling, dark count rate

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review