Gevaux, Lou, Simonot, Lionel, Clerc, Raphael, Gerardin, Morgane, Hebert, Mathieu · 2020 · Applied Optics
Cited by 13

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

In many commercial instruments for measuring reflectance, the area illuminated on the measured object is identical to the area from which light is collected. This configuration is suitable for strongly scattering materials such as paper, but issues arise with translucent materials, because a portion of the incident light spreads around the illuminated area by subsurface transport and escapes the detection system. This phenomenon, referred to as edge loss, yields erroneous, underestimated reflectance measurements. In the case of colored and opalescent materials, the impact of edge loss on the measured reflectance varies with the wavelength, which is a significant issue for spectrophotometer and colorimeter users. In the present study, we investigate the edge-loss phenomenon with an emphasis on human skin measurement. In particular, we use a mathematical model to estimate the PSF of translucent materials, relying on the diffusion approximation of the radiative transfer theory, to predict edge-loss measurement error. We use this model to discuss the suitability of several commercial spectrophotometers to accurately measure the translucent materials of various optical properties and show that not all devices can adapt to all translucent materials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/ao.403694

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 28

  1. Dupuy, 2018, ACM Trans. Graph, 37, 274, 10.1145/3272127.3275059 · doi:10.1145/3272127.3275059
  2. Gerardin, 2019, A translucency classification for computer graphics, 2019, 1
  3. Gigilashvili, 2019, Impact of shape on apparent translucency differences, 2019, 132
  4. Bolt, 1994, Phys. Med. Biol., 39, 1133, 10.1088/0031-9155/39/7/006 · DOI · Paper page
  5. Lee, 2004, Dent. Mater., 20, 116, 10.1016/S0109-5641(03)00072-1 · doi:10.1016/s0109-5641(03)00072-1
  6. Johnston, 1996, J. Dent. Res., 75, 752, 10.1177/00220345960750020401 · doi:10.1177/00220345960750020401
  7. Takiwaki, 2002, Skin Res. Technol., 8, 94, 10.1034/j.1600-0846.2001.80206.x · doi:10.1034/j.1600-0846.2001.80206.x
  8. Yoshida, 2011, J. Biomed. Opt., 16, 117003, 10.1117/1.3646208 · doi:10.1117/1.3646208
  9. Vidovič, 2015, Proc. SPIE, 9303, 930307, 10.1117/12.2077188 · DOI
  10. Jacques, 2013, Phys. Med. Biol., 58, R37, 10.1088/0031-9155/58/11/R37 · DOI · Paper page
  11. Hsia, 1976, The Translucent Blurring Effect: Method of Evaluation and Estimation
  12. Nicodemus, 1977, Geometrical Considerations and Nomenclature for Reflectance, 10.6028/NBS.MONO.160 · DOI · Paper page
  13. McCluney, 1994, Introduction to Radiometry and Photometry
  14. Ishimaru, 1978, Wave Propagation and Scattering in Random Media, Single Scattering and Transport Theory, 1
  15. Baddour, 2011, Two-dimensional Fourier transforms in polar coordinates, 165, 1
  16. Patterson, 1989, Proc. SPIE, 1065, 115, 10.1117/12.978011 · doi:10.1117/12.978011
  17. Farrell, 1992, Med. Phys., 19, 879, 10.1118/1.596777 · DOI · Paper page
  18. Zemp, 2013, J. Biomed. Opt., 18, 067005, 10.1117/1.JBO.18.6.067005 · doi:10.1117/1.jbo.18.6.067005
  19. Donner, 2008, Rendering translucent materials using photon diffusion, 10.1145/1401132.1401138 · doi:10.1145/1401132.1401138
  20. Keijzer, 1988, Appl. Opt., 27, 1820, 10.1364/AO.27.001820 · DOI · Paper page
  21. Igarashi, 2007, Found. Trends Comput. Graph. Vision, 3, 1, 10.1561/0600000013 · DOI · Paper page
  22. Gevaux, 2019, J. Biomed. Opt., 24, 066002, 10.1117/1.JBO.24.6.066002 · DOI
  23. Foschum, 2011, Rev. Sci. Instrum., 82, 103104, 10.1063/1.3648120 · DOI
  24. Jensen, 2001, A practical model for subsurface light transport, 10.1145/383259.383319 · DOI · Paper page
  25. Levinson, 2005, Sol. Energy Mater. Solar Cells, 89, 319, 10.1016/j.solmat.2004.11.012 · DOI · Paper page
  26. Doi, 2006, Proc. SPIE, 6062, 606204, 10.1117/12.642728 · doi:10.1117/12.642728
  27. Yoshida, 2016, Opt. Rev., 23, 579, 10.1007/s10043-016-0237-3 · DOI
  28. Urban, 2019, ACM Trans. Graph., 38, 21, 10.1145/3319910 · doi:10.1145/3319910

Cited by

See all 13

Metadata

Authors
Gevaux, L., Simonot, L., Clerc, R., Gerardin, M., & Hebert, M.
Venue
Applied Optics
Published
2020-10-01
Volume
59
Issue
28
Pages
8939
ISSN
  • 1559-128X
  • 2155-3165
Cited by
13
References
1
Language
en
Licence
Funders
  • Région Auvergne-Rhône-Alpes (ARC 6)
  • Agence Nationale de la Recherche (ANR-10-LABX-0075, LABEX MANUTECH-SISE)
  • European Metrology Programme for Innovation and Research (EMPIR)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluating edge loss in the reflectance measurement of translucent materials. https://app.cochat.ai/papers/10.1364/ao.403694
The paper
Gevaux, L., Simonot, L., Clerc, R., Gerardin, M., & Hebert, M. (2020). Evaluating edge loss in the reflectance measurement of translucent materials. Applied Optics. https://doi.org/10.1364/ao.403694

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.