Evaluating edge loss in the reflectance measurement of translucent materials
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In many commercial instruments for measuring reflectance, the area illuminated on the measured object is identical to the area from which light is collected. This configuration is suitable for strongly scattering materials such as paper, but issues arise with translucent materials, because a portion of the incident light spreads around the illuminated area by subsurface transport and escapes the detection system. This phenomenon, referred to as edge loss, yields erroneous, underestimated reflectance measurements. In the case of colored and opalescent materials, the impact of edge loss on the measured reflectance varies with the wavelength, which is a significant issue for spectrophotometer and colorimeter users. In the present study, we investigate the edge-loss phenomenon with an emphasis on human skin measurement. In particular, we use a mathematical model to estimate the PSF of translucent materials, relying on the diffusion approximation of the radiative transfer theory, to predict edge-loss measurement error. We use this model to discuss the suitability of several commercial spectrophotometers to accurately measure the translucent materials of various optical properties and show that not all devices can adapt to all translucent materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Under these conditions, the assumptions of the model described here are applicable.”
In the citing paper
“as demonstrated in [26], it is appropriate to select the illuminated area (or respectively, the observed area) larger than the convolution between the material’s diffusion point spread function and the observed area (or respectively, the illuminated area).”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jonasson, H., Fredriksson, I., Bergstrand, S., Östgren, C. J., Larsson, M., & Strömberg, T. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.12.121608 · Cited by 52
Research works printed but not linked: 28
- Dupuy, 2018, ACM Trans. Graph, 37, 274, 10.1145/3272127.3275059 · doi:10.1145/3272127.3275059
- Gerardin, 2019, A translucency classification for computer graphics, 2019, 1
- Gigilashvili, 2019, Impact of shape on apparent translucency differences, 2019, 132
- Bolt, 1994, Phys. Med. Biol., 39, 1133, 10.1088/0031-9155/39/7/006 · DOI · Paper page
- Lee, 2004, Dent. Mater., 20, 116, 10.1016/S0109-5641(03)00072-1 · doi:10.1016/s0109-5641(03)00072-1
- Johnston, 1996, J. Dent. Res., 75, 752, 10.1177/00220345960750020401 · doi:10.1177/00220345960750020401
- Takiwaki, 2002, Skin Res. Technol., 8, 94, 10.1034/j.1600-0846.2001.80206.x · doi:10.1034/j.1600-0846.2001.80206.x
- Yoshida, 2011, J. Biomed. Opt., 16, 117003, 10.1117/1.3646208 · doi:10.1117/1.3646208
- Vidovič, 2015, Proc. SPIE, 9303, 930307, 10.1117/12.2077188 · DOI
- Jacques, 2013, Phys. Med. Biol., 58, R37, 10.1088/0031-9155/58/11/R37 · DOI · Paper page
- Hsia, 1976, The Translucent Blurring Effect: Method of Evaluation and Estimation
- Nicodemus, 1977, Geometrical Considerations and Nomenclature for Reflectance, 10.6028/NBS.MONO.160 · DOI · Paper page
- McCluney, 1994, Introduction to Radiometry and Photometry
- Ishimaru, 1978, Wave Propagation and Scattering in Random Media, Single Scattering and Transport Theory, 1
- Baddour, 2011, Two-dimensional Fourier transforms in polar coordinates, 165, 1
- Patterson, 1989, Proc. SPIE, 1065, 115, 10.1117/12.978011 · doi:10.1117/12.978011
- Farrell, 1992, Med. Phys., 19, 879, 10.1118/1.596777 · DOI · Paper page
- Zemp, 2013, J. Biomed. Opt., 18, 067005, 10.1117/1.JBO.18.6.067005 · doi:10.1117/1.jbo.18.6.067005
- Donner, 2008, Rendering translucent materials using photon diffusion, 10.1145/1401132.1401138 · doi:10.1145/1401132.1401138
- Keijzer, 1988, Appl. Opt., 27, 1820, 10.1364/AO.27.001820 · DOI · Paper page
- Igarashi, 2007, Found. Trends Comput. Graph. Vision, 3, 1, 10.1561/0600000013 · DOI · Paper page
- Gevaux, 2019, J. Biomed. Opt., 24, 066002, 10.1117/1.JBO.24.6.066002 · DOI
- Foschum, 2011, Rev. Sci. Instrum., 82, 103104, 10.1063/1.3648120 · DOI
- Jensen, 2001, A practical model for subsurface light transport, 10.1145/383259.383319 · DOI · Paper page
- Levinson, 2005, Sol. Energy Mater. Solar Cells, 89, 319, 10.1016/j.solmat.2004.11.012 · DOI · Paper page
- Doi, 2006, Proc. SPIE, 6062, 606204, 10.1117/12.642728 · doi:10.1117/12.642728
- Yoshida, 2016, Opt. Rev., 23, 579, 10.1007/s10043-016-0237-3 · DOI
- Urban, 2019, ACM Trans. Graph., 38, 21, 10.1145/3319910 · doi:10.1145/3319910
Cited by
Gautheron, A., Clerc, R., Duveiller, V., Simonot, L., Montcel, B., & Hébert, M. (2024) · Optics Express · doi:10.1364/oe.510888 · Cited by 8
Self-citation
Metadata
- Authors
- Gevaux, L., Simonot, L., Clerc, R., Gerardin, M., & Hebert, M.
- ORCID
- Gevaux, Lou
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 2020-10-01
- Volume
- 59
- Issue
- 28
- Pages
- 8939
- ISSN
- 1559-128X
- 2155-3165
- Cited by
- 13
- References
- 1
- Language
- en
- Licence
- doi.org/10.1364/OA_License_v1#VOR (vor)
- opg.optica.org/policies/opg-tdm-policy.json (tdm)
- Funders
- Région Auvergne-Rhône-Alpes (ARC 6)
- Agence Nationale de la Recherche (ANR-10-LABX-0075, LABEX MANUTECH-SISE)
- European Metrology Programme for Innovation and Research (EMPIR)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluating edge loss in the reflectance measurement of translucent materials. https://app.cochat.ai/papers/10.1364/ao.403694
- The paper
- Gevaux, L., Simonot, L., Clerc, R., Gerardin, M., & Hebert, M. (2020). Evaluating edge loss in the reflectance measurement of translucent materials. Applied Optics. https://doi.org/10.1364/ao.403694
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.