Optical Fiber Probe for Biomedical Raman Spectroscopy
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
In vitro experiments have demonstrated the ability of Raman spectroscopy to diagnose a wide variety of diseases. Recent in vivo investigations performed with optical fiber probes were promising but generally limited to easily accessible organs, often requiring relatively long collection times. We have implemented an optical design strategy to utilize system throughput fully by characterizing the Raman distribution from tissue. This scheme optimizes collection efficiency, minimizes noise, and has resulted in small-diameter, highly efficient Raman probes that are capable of collecting high-quality data in 1 s. Performance has been tested through simulations and experiments with tissue models and several in vitro tissue types, demonstrating that this new design can advance Raman spectroscopy as a clinically practical technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Absorption and Scattering of Light by Small Particles
Bohren, C. F., & Huffman, D. R. (1998) · doi:10.1002/9783527618156 · Cited by 18,474
Molecular Bases of the Acute Coronary Syndromes
Libby, P. (1995) · Circulation · doi:10.1161/01.cir.91.11.2844 · Cited by 2,028
Raman Spectroscopy for Chemical Analysis
McCreery, R. L. (2000) · Wiley eBooks · doi:10.1002/0471721646 · Cited by 1,440
Prospects for in vivo Raman spectroscopy
Hanlon, E. B., Manoharan, R., Koo, T.-W., Shafer, K. E., Motz, J. T., Fitzmaurice, M., Kramer, J. R., Itzkan, I., Dasari, R. R., & Feld, M. S. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/201 · Cited by 894
Self-citationRaman spectroscopy for the detection of cancers and precancers
Mahadevan-Jansen, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.227815 · Cited by 475
Fiber optic probes for biomedical optical spectroscopy
Utzinger, U., & Richards-Kortum, R. R. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528207 · Cited by 443
Haka, A. S., Shafer‐Peltier, K., Fitzmaurice, M., Crowe, J. P., Dasari, R. R., & Feld, M. S. (2002) · PubMed · Cited by 348
Self-citationNon-Invasive Raman Spectroscopic Detection of Carotenoids in Human Skin
Hata, T. R., Scholz, T. A., Pershing, L. K., Ermakov, I. V., McClane, R. W., Khachik, F., & Gellermann, W. (2000) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.2000.00060.x · Cited by 343
Radiometry and the detection of optical radiation
Boyd, R. W. (1983) · Andalas University Repository (Andalas University) · Cited by 323
In vitro andin vivo Raman spectroscopy of human skin
Caspers, P. J., Lucassen, G. W., Wolthuis, R., Bruining, H. A., & Puppels, G. J. (1998) · Biospectroscopy · doi:10.1002/(sici)1520-6343(1998)4:5+<s31::aid-bspy4>3.0.co;2-m · Cited by 314
Shim, M. G., Wong Kee Song, L.-M., Marcon, N. E., & Wilson, B. C. (2000) · Photochemistry and Photobiology · doi:10.1562/0031-8655(2000)0720146ivnirs2.0.co2 · Cited by 296
Vulnerable Plaque: Relation of Characteristics to Degree of Stenosis in Human Coronary Arteries
Mann, J. M., & Davies, M. J. (1996) · Circulation · doi:10.1161/01.cir.94.5.928 · Cited by 278
Shafer‐Peltier, K. E., Haka, A. S., Fitzmaurice, M., Crowe, J., Myles, J., Dasari, R. R., & Feld, M. S. (2002) · Journal of Raman Spectroscopy · doi:10.1002/jrs.877 · Cited by 270
Self-citationCaspers, P. J., Lucassen, G. W., Bruining, H. A., & Puppels, G. J. (2000) · Journal of Raman Spectroscopy · doi:10.1002/1097-4555(200008/09)31:8/9<813::aid-jrs573>3.0.co;2-7 · Cited by 262
Near-Infrared Raman Spectroscopy for in vivo Detection of Cervical Precancers
Utzinger, U., Heintzelman, D. L., Mahadevan-Jansen, A., Malpica, A., Follen, M., & Richards-Kortum, R. (2001) · Applied Spectroscopy · doi:10.1366/0003702011953018 · Cited by 251
Römer, T. J., Brennan, J. F., Fitzmaurice, M., Feldstein, M., Deinum, G., Myles, J. L., Kramer, J. R., Lees, R. S., & Feld, M. S. (1998) · Circulation · doi:10.1161/01.cir.97.9.878 · Cited by 184
Self-citationRaman Spectroscopy and Fluorescence Photon Migration for Breast Cancer Diagnosis and Imaging
Manoharan, R., Shafer, K., Perelman, L., Wu, J., Chen, K., Deinum, G., Fitzmaurice, M., Myles, J., Crowe, J., Dasarl, R. R., et al. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb05160.x · Cited by 170
Self-citationBuschman, H. P. J., Deinum, G., Motz, J. T., Fitzmaurice, M., Kramer, J. R., van der Laarse, A., Bruschke, A. V. G., & Feld, M. S. (2001) · Cardiovascular Pathology · doi:10.1016/s1054-8807(01)00064-3 · Cited by 143
Self-citationDevelopment of anIn Vivo Raman Spectroscopic System for Diagnostic Applications
Shim, M. G., & Wilson, B. C. (1997) · Journal of Raman Spectroscopy · doi:10.1002/(sici)1097-4555(199702)28:2/3<131::aid-jrs68>3.0.co;2-s · Cited by 132
Near-Infrared Raman Spectrometer Systems for Human Tissue Studies
Brennan, J. F., Wang, Y., Dasari, R. R., & Feld, M. S. (1997) · Applied Spectroscopy · doi:10.1366/0003702971940134 · Cited by 126
Self-citationDiagnosis of human coronary atherosclerosis by morphology-based Raman spectroscopy
Buschman, H. P. J., Motz, J. T., Deinum, G., Römer, T. J., Fitzmaurice, M., Kramer, J. R., van der Laarse, A., Bruschke, A. V. G., & Feld, M. S. (2001) · Cardiovascular Pathology · doi:10.1016/s1054-8807(01)00063-1 · Cited by 96
Self-citationReal‐time tissue characterization on the basis of in vivo Raman spectra
Schut, T. C. B., Wolthuis, R., Caspers, P. J., & Puppels, G. J. (2002) · Journal of Raman Spectroscopy · doi:10.1002/jrs.852 · Cited by 87
Optical properties of human blood vessel wall and plaque
van Gemert, M. J. C., Verdaasdonk, R. M., Stassen, E. G., Schets, G. A. C. M., Gijsbers, G. H. M., & Bonnier, J. J. R. M. (1985) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900050305 · Cited by 77
Cooney, T. F., Skinner, H. T., & Angel, S. M. (1996) · Applied Spectroscopy · doi:10.1366/0003702963905574 · Cited by 50
Cited by
Diagnosing breast cancer by using Raman spectroscopy
Haka, A. S., Shafer-Peltier, K. E., Fitzmaurice, M., Crowe, J., Dasari, R. R., & Feld, M. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0501390102 · Cited by 630
Self-citationNoninvasive molecular imaging of small living subjects using Raman spectroscopy
Keren, S., Zavaleta, C., Cheng, Z., de la Zerda, A., Gheysens, O., & Gambhir, S. S. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0710575105 · Cited by 604
In vivo Margin Assessment during Partial Mastectomy Breast Surgery Using Raman Spectroscopy
Haka, A. S., Volynskaya, Z., Gardecki, J. A., Nazemi, J., Lyons, J., Hicks, D., Fitzmaurice, M., Dasari, R. R., Crowe, J. P., & Feld, M. S. (2006) · Cancer Research · doi:10.1158/0008-5472.can-05-2815 · Cited by 424
Self-citationMarkos, C., Travers, J. C., Abdolvand, A., Eggleton, B. J., & Bang, O. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.045003 · Cited by 314
Noninvasive Monitoring of Blood Glucose with Raman Spectroscopy
Pandey, R., Paidi, S. K., Valdez, T. A., Zhang, C., Spegazzini, N., Dasari, R. R., & Barman, I. (2017) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00472 · Cited by 290
Self-citation
Metadata
- Authors
- Motz, J. T., Hunter, M., Galindo, L. H., Gardecki, J. A., Kramer, J. R., Dasari, R. R., & Feld, M. S.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 2004-01-20
- Volume
- 43
- Issue
- 3
- Pages
- 542
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2163144045
- Cited by
- 248
- References
- 24
- FWCI
- 7.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.