The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Optical methods for distance and displacement measurements
Abstract
This tutorial reviews various noncontact optical sensing techniques that can be used to measure distances to objects, and related parameters such as displacements, surface profiles, velocities and vibrations. The techniques that are discussed and compared include intensity-based sensing, triangulation, time-of-flight sensing, confocal sensing, Doppler sensing, and various kinds of interferometric sensing with both high- and low-coherence sources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Othonos, A. (1997) · Review of Scientific Instruments · doi:10.1063/1.1148392 · Cited by 1,332
Overview of three-dimensional shape measurement using optical methods
Brown, G. M. (2000) · Optical Engineering · doi:10.1117/1.602438 · Cited by 1,327
Measurement of intraocular distances by backscattering spectral interferometry
Fercher, A. F., Hitzenberger, C. K., Kamp, G., & El-Zaiat, S. Y. (1995) · Optics Communications · doi:10.1016/0030-4018(95)00119-s · Cited by 1,212
Optical coherence tomography (OCT): a review
Schmitt, J. M. (1999) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.796348 · Cited by 1,188
Optical Coherence Tomography: An Emerging Technology for Biomedical Imaging and Optical Biopsy
Fujimoto, J. G., Pitris, C., Boppart, S. A., & Brezinski, M. E. (2000) · Neoplasia · doi:10.1038/sj.neo.7900071 · Cited by 1,138
Compact system for high-speed velocimetry using heterodyne techniques
Strand, O. T., Goosman, D. R., Martinez, C., Whitworth, T. L., & Kuhlow, W. W. (2006) · Review of Scientific Instruments · doi:10.1063/1.2336749 · Cited by 906
Laser ranging: a critical review of usual techniques for distance measurement
Bosch, T. (2001) · Optical Engineering · doi:10.1117/1.1330700 · Cited by 854
LOCALIZED FLUID FLOW MEASUREMENTS WITH AN He–Ne LASER SPECTROMETER
Yeh, Y., & Cummins, H. Z. (1964) · Applied Physics Letters · doi:10.1063/1.1753925 · Cited by 767
Solid-state time-of-flight range camera
Lange, R., & Seitz, P. (2001) · IEEE Journal of Quantum Electronics · doi:10.1109/3.910448 · Cited by 694
Active, optical range imaging sensors
Besl, P. J. (1988) · Machine Vision and Applications · doi:10.1007/bf01212277 · Cited by 559
Ultrahigh-resolution optical coherence tomography
Drexler, W. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1629679 · Cited by 553
Fercher, A. F. (1996) · Journal of Biomedical Optics · doi:10.1117/12.231361 · Cited by 534
Laser diode self-mixing technique for sensing applications
Giuliani, G., Norgia, M., Donati, S., & Bosch, T. (2002) · Journal of Optics A: Pure and Applied Optics · doi:10.1088/1464-4258/4/6/371 · Cited by 527
Laser Doppler Vibrometry: Development of advanced solutions answering to technology's needs
Castellini, P., Martarelli, M., & Tomasini, E. P. (2006) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2005.11.015 · Cited by 483
Developing self‐mixing interferometry for instrumentation and measurements
Donati, S. (2012) · Laser & Photonics Reviews · doi:10.1002/lpor.201100002 · Cited by 363
Megahertz OCT for ultrawide-field retinal imaging with a 1050nm Fourier domain mode-locked laser
Klein, T., Wieser, W., Eigenwillig, C. M., Biedermann, B. R., & Huber, R. (2011) · Optics Express · doi:10.1364/oe.19.003044 · Cited by 318
A system for extracting three-dimensional measurements from a stereo pair of TV cameras
Yakimovsky, Y., & Cunningham, R. (1978) · Computer Graphics and Image Processing · doi:10.1016/0146-664x(78)90112-0 · Cited by 306
3D shape scanning with a time-of-flight camera
Cui, Y., Schuon, S., Chan, D., Thrun, S., & Theobalt, C. (2010) · 2010 IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2010.5540082 · Cited by 293
Fiber optic lever displacement transducer
Cook, R. O., & Hamm, C. W. (1979) · Applied Optics · doi:10.1364/ao.18.003230 · Cited by 167
Continuous measurement of intestinal mucosal blood flow by laser-Doppler velocimetry
Shepherd, A. P., & Riedel, G. L. (1982) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.1982.242.6.g668 · Cited by 163
Displacement field estimation for a two-dimensional structure using fiber Bragg grating sensors
Rapp, S., Kang, L.-H., Han, J.-H., Mueller, U. C., & Baier, H. (2009) · Smart Materials and Structures · doi:10.1088/0964-1726/18/2/025006 · Cited by 162
Absolute optical ranging using low coherence interferometry
Danielson, B. L., & Boisrobert, C. Y. (1991) · Applied Optics · doi:10.1364/ao.30.002975 · Cited by 134
Self-mixing interferometry based on a double-modulation technique for absolute distance measurement
Guo, D., & Wang, M. (2007) · Applied Optics · doi:10.1364/ao.46.001486 · Cited by 95
Absolute interferometry with a 670-nm external cavity diode laser
Stone, J. A., Stejskal, A., & Howard, L. P. (1999) · Applied Optics · doi:10.1364/ao.38.005981 · Cited by 87
High-precision absolute distance and vibration measurement with frequency scanned interferometry
Yang, H., Deibel, J. A., Nyberg, S., et al. (2005) · Applied Optics · doi:10.1364/ao.44.003937 · Cited by 81
Receiver channel with resonance-based timing detection for a laser range finder
Pehkonen, J., Palojärvi, P., & Kostamovaara, J. (2006) · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · doi:10.1109/tcsi.2005.858758 · Cited by 42
Fiber-optic diaphragm pressure sensor with automatic intensity compensation
Li-bo, Y., & Anping, Q. (1991) · Sensors and Actuators A Physical · doi:10.1016/0924-4247(91)80005-a · Cited by 32
Compensation of an optical fibre reflective sensor
Cockshott, C. P., & Pacaud, S. J. (1989) · Sensors and Actuators · doi:10.1016/0250-6874(89)80076-9 · Cited by 20
Shafir, E., Shtilman, M., Naor, E., et al. (2011) · IET Optoelectronics · doi:10.1049/iet-opt.2009.0088 · Cited by 1
Self-citation
Cited by
Ultrafast optical ranging using microresonator soliton frequency combs
Trocha, P., Karpov, M., Ganin, D., Pfeiffer, M. H. P., Kordts, A., Wolf, S., Krockenberger, J., Marin-Palomo, P., Weimann, C., Randel, S., et al. (2018) · Science · doi:10.1126/science.aao3924 · Cited by 898
Underwater optical wireless communications, networking, and localization: A survey
Saeed, N., Celik, A., Al-Naffouri, T. Y., & Alouini, M.-S. (2019) · Ad Hoc Networks · doi:10.1016/j.adhoc.2019.101935 · Cited by 560
A Survey on LiDAR Scanning Mechanisms
Raj, T., Hashim, F. H., Huddin, A. B., Ibrahim, M. F., & Hussain, A. (2020) · Electronics · doi:10.3390/electronics9050741 · Cited by 413
Metasurface Micro/Nano-Optical Sensors: Principles and Applications
Qin, J., Jiang, S., Wang, Z., Cheng, X., Li, B., Shi, Y., Tsai, D. P., Liu, A. Q., Huang, W., & Zhu, W. (2022) · ACS Nano · doi:10.1021/acsnano.2c03310 · Cited by 359
Low-overhead distribution strategy for simulation and optimization of large-area metasurfaces
Skarda, J., Trivedi, R., Su, L., Ahmad-Stein, D., Kwon, H., Han, S., Fan, S., & Vučković, J. (2022) · npj Computational Materials · doi:10.1038/s41524-022-00774-y · Cited by 44
Metadata
- Authors
- Berkovic, G., & Shafir, E.
- Venue
- Advances in Optics and Photonics
- Publisher
- Optica Publishing Group
- Published
- 2012-09-11
- Volume
- 4
- Issue
- 4
- Pages
- 441
- ISSN
- 1943-8206 (ISSN-L)
- OpenAlex
- W2051162467
- Cited by
- 411
- References
- 30
- FWCI
- 11.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.