The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Simultaneous multiple-emitter fitting for single molecule super-resolution imaging
Open accessAbstract
Single molecule localization based super-resolution imaging techniques require repeated localization of many single emitters. We describe a method that uses the maximum likelihood estimator to localize multiple emitters simultaneously within a single, two-dimensional fitting sub-region, yielding an order of magnitude improvement in the tolerance of the analysis routine with regards to the single-frame active emitter density. Multiple-emitter fitting enables the overall performance of single-molecule super-resolution to be improved in one or more of several metrics that result in higher single-frame density of localized active emitters. For speed, the algorithm is implemented on Graphics Processing Unit (GPU) architecture, resulting in analysis times on the order of minutes. We show the performance of multiple emitter fitting as a function of the single-frame active emitter density. We describe the details of the algorithm that allow robust fitting, the details of the GPU implementation, and the other imaging processing steps required for the analysis of data sets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Super-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
Cited by
Galectin-3 Coordinates a Cellular System for Lysosomal Repair and Removal
Jia, J., Claude-Taupin, A., Gu, Y., Choi, S. W., Peters, R., Bissa, B., Mudd, M. H., Allers, L., Pallikkuth, S., Lidke, K. A., et al. (2020) · Developmental Cell · doi:10.1016/j.devcel.2019.10.025 · Cited by 434
Self-citationQuantitative evaluation of software packages for single-molecule localization microscopy
Sage, D., Kirshner, H., Pengo, T., Stuurman, N., Min, J., Manley, S., & Unser, M. (2015) · Nature Methods · doi:10.1038/nmeth.3442 · Cited by 396
ATG9A protects the plasma membrane from programmed and incidental permeabilization
Claude-Taupin, A., Jia, J., Bhujabal, Z., Garfa-Traoré, M., Kumar, S., da Silva, G. P. D., Javed, R., Gu, Y., Allers, L., Peters, R., et al. (2021) · Nature Cell Biology · doi:10.1038/s41556-021-00706-w · Cited by 92
Self-citationUSP1-Trapping Lesions as a Source of DNA Replication Stress and Genomic Instability
Coleman, K. E., Yin, Y., Lui, S. K. L., Keegan, S., Fenyo, D., Smith, D. J., Rothenberg, E., & Huang, T. T. (2022) · Nature Communications · doi:10.1038/s41467-022-29369-3 · Cited by 50
Metadata
- Authors
- Huang, F., Schwartz, S. L., Byars, J. M., & Lidke, K. A.
- Venue
- Biomedical Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2011-04-29
- Volume
- 2
- Issue
- 5
- Pages
- 1377
- ISSN
- 2156-7085 (ISSN-L)
- OpenAlex
- W2062317708
- Cited by
- 311
- References
- 2
- FWCI
- 16.14
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous multiple-emitter fitting for single molecule super-resolution imaging. https://app.cochat.ai/papers/10.1364/boe.2.001377
- The paper
- Huang, F., Schwartz, S. L., Byars, J. M., & Lidke, K. A. (2011). Simultaneous multiple-emitter fitting for single molecule super-resolution imaging. Biomedical Optics Express. https://doi.org/10.1364/boe.2.001377
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.