The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Simultaneous multiple-emitter fitting for single molecule super-resolution imaging
Open accessAbstract
Single molecule localization based super-resolution imaging techniques require repeated localization of many single emitters. We describe a method that uses the maximum likelihood estimator to localize multiple emitters simultaneously within a single, two-dimensional fitting sub-region, yielding an order of magnitude improvement in the tolerance of the analysis routine with regards to the single-frame active emitter density. Multiple-emitter fitting enables the overall performance of single-molecule super-resolution to be improved in one or more of several metrics that result in higher single-frame density of localized active emitters. For speed, the algorithm is implemented on Graphics Processing Unit (GPU) architecture, resulting in analysis times on the order of minutes. We show the performance of multiple emitter fitting as a function of the single-frame active emitter density. We describe the details of the algorithm that allow robust fitting, the details of the GPU implementation, and the other imaging processing steps required for the analysis of data sets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Hell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
Ultra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Gustafsson, M. G. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406877102 · Cited by 2,224
Subdiffraction‐Resolution Fluorescence Imaging with Conventional Fluorescent Probes
Heilemann, M., van de Linde, S., Schüttpelz, M., Kasper, R., Seefeldt, B., Mukherjee, A., Tinnefeld, P., & Sauer, M. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200802376 · Cited by 1,866
Super-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
A guide to super-resolution fluorescence microscopy
Schermelleh, L., Heintzmann, R., & Leonhardt, H. (2010) · Journal of Cell Biology · doi:10.1083/jcb.201002018 · Cited by 1,255
Dynamic multiple-target tracing to probe spatiotemporal cartography of cell membranes
Sergé, A., Bertaux, N., Rigneault, H., & Marguet, D. (2008) · Nature Methods · doi:10.1038/nmeth.1233 · Cited by 632
Localization Accuracy in Single-Molecule Microscopy
Ober, R. J., Ram, S., & Ward, E. S. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74193-4 · Cited by 587
Superresolution Imaging using Single-Molecule Localization
Patterson, G., Davidson, M., Manley, S., & Lippincott-Schwartz, J. (2010) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.012809.103444 · Cited by 527
Fast, single-molecule localization that achieves theoretically minimum uncertainty
Smith, C. S., Joseph, N., Rieger, B., & Lidke, K. A. (2010) · Nature Methods · doi:10.1038/nmeth.1449 · Cited by 522
Self-citationGaussian approximations of fluorescence microscope point-spread function models
Zhang, B., Zerubia, J., & Olivo-Marin, J.-C. (2007) · Applied Optics · doi:10.1364/ao.46.001819 · Cited by 504
Hell, S., & Stelzer, E. H. K. (1992) · Optics Communications · doi:10.1016/0030-4018(92)90185-t · Cited by 415
Single-molecule high-resolution imaging with photobleaching
Gordon, M. P., Ha, T., & Selvin, P. R. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0401638101 · Cited by 372
Westphal, V., Rizzoli, S. O., Lauterbach, M. A., Kamin, D., & Hell, S. W. (2009) · Advances in Imaging · doi:10.1364/ntm.2009.nma1 · Cited by 365
Nanometer-localized multiple single-molecule fluorescence microscopy
Qu, X., Wu, D., Mets, L., & Scherer, N. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402155101 · Cited by 304
Beyond Rayleigh's criterion: A resolution measure with application to single-molecule microscopy
Ram, S., Ward, E. S., & Ober, R. J. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508047103 · Cited by 259
Accuracy of the Gaussian Point Spread Function model in 2D localization microscopy
Stallinga, S., & Rieger, B. (2010) · Optics Express · doi:10.1364/oe.18.024461 · Cited by 234
Make them Blink: Probes for Super‐Resolution Microscopy
Vogelsang, J., Steinhauer, C., Forthmann, C., Stein, I. H., Person‐Skegro, B., Cordes, T., & Tinnefeld, P. (2010) · ChemPhysChem · doi:10.1002/cphc.201000189 · Cited by 199
Analysis Method for Measuring Submicroscopic Distances with Blinking Quantum Dots
Lagerholm, B. C., Averett, L. E., Weinreb, G. E., Jacobson, K., & Thompson, N. L. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.079178 · Cited by 52
Theoretical Limits on Errors and Acquisition Rates in Localizing Switchable Fluorophores
Small, A. R. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2008.11.001 · Cited by 42
Chi, K. R. (2009) · Nature · doi:10.1038/462675a · Cited by 21
Cited by
Ovesný, M., Křížek, P., Borkovec, J., Švindrych, Z., & Hagen, G. M. (2014) · Bioinformatics · doi:10.1093/bioinformatics/btu202 · Cited by 1,506
Measuring image resolution in optical nanoscopy
Nieuwenhuizen, R. P. J., Lidke, K. A., Bates, M., Puig, D. L., Grünwald, D., Stallinga, S., & Rieger, B. (2013) · Nature Methods · doi:10.1038/nmeth.2448 · Cited by 800
Self-citationDeep-STORM: super-resolution single-molecule microscopy by deep learning
Nehme, E., Weiss, L. E., Michaeli, T., & Shechtman, Y. (2018) · Optica · doi:10.1364/optica.5.000458 · Cited by 604
Deep learning massively accelerates super-resolution localization microscopy
Ouyang, W., Aristov, A., Lelek, M., Hao, X., & Zimmer, C. (2018) · Nature Biotechnology · doi:10.1038/nbt.4106 · Cited by 570
Single Particle Tracking: From Theory to Biophysical Applications
Shen, H., Tauzin, L. J., Baiyasi, R., Wang, W., Moringo, N., Shuang, B., & Landes, C. F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00815 · Cited by 536
Metadata
- Authors
- Huang, F., Schwartz, S. L., Byars, J. M., & Lidke, K. A.
- Venue
- Biomedical Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2011-04-29
- Volume
- 2
- Issue
- 5
- Pages
- 1377
- ISSN
- 2156-7085 (ISSN-L)
- OpenAlex
- W2062317708
- Cited by
- 311
- References
- 24
- FWCI
- 16.14
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.