Optical pacing of the adult rabbit heart
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Optical pacing has been demonstrated to be a viable alternative to electrical pacing in embryonic hearts. In this study, the feasibility of optically pacing an adult rabbit heart was explored. Hearts from adult New Zealand White rabbits (n = 9) were excised, cannulated and perfused on a modified Langendorff apparatus. Pulsed laser light (λ = 1851 nm) was directed to either the left or right atrium through a multimode optical fiber. An ECG signal from the left ventricle and a trigger pulse from the laser were recorded simultaneously to determine when capture was achieved. Successful optical pacing was demonstrated by obtaining pacing capture, stopping, then recapturing as well as by varying the pacing frequency. Stimulation thresholds measured at various pulse durations suggested that longer pulses (8 ms) had a lower energy capture threshold. To determine whether optical pacing caused damage, two hearts were perfused with 30 µM of propidium iodide and analyzed histologically. A small number of cells near the stimulation site had compromised cell membranes, which probably limited the time duration over which pacing was maintained. Here, short-term optical pacing (few minutes duration) is demonstrated in the adult rabbit heart for the first time. Future studies will be directed to optimize optical pacing parameters to decrease stimulation thresholds and may enable longer-term pacing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nazarian, S., Hansford, R., Roguin, A., Goldsher, D., Zviman, M. M., Lardo, A. C., Caffo, B. S., Frick, K. D., Kraut, M. A., Kamel, I. R., et al. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-7-201110040-00004 · Cited by 302
Cited by
Biological effects and medical applications of infrared radiation
Tsai, S.-R., & Hamblin, M. R. (2017) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/j.jphotobiol.2017.04.014 · Cited by 477
Optical Stimulation of Neurons
C. Thompson, A., R. Stoddart, P., & Jansen, E. D. (2015) · Current Molecular Imaging · doi:10.2174/2211555203666141117220611 · Cited by 105
“Optical pacing of the heart was further explored in [64].”
BackgroundMicelle-enabled self-assembly of porous and monolithic carbon membranes for bioelectronic interfaces
Fang, Y., Prominski, A., Rotenberg, M. Y., Meng, L., Acarón Ledesma, H., Lv, Y., Yue, J., Schaumann, E., Jeong, J., Yamamoto, N., et al. (2021) · Nature Nanotechnology · doi:10.1038/s41565-020-00805-z · Cited by 66
Optical stimulation of neural tissue
Richardson, R. T., Ibbotson, M. R., Thompson, A. C., Wise, A. K., & Fallon, J. B. (2020) · Healthcare Technology Letters · doi:10.1049/htl.2019.0114 · Cited by 40
Design Considerations for Implantable Neural Circuits and Systems
Hsu, W.-Y., Hsieh, P.-H., & Chen, H. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_19 · Cited by 1
Metadata
- Authors
- Jenkins, M. W., Wang, Y. T., Doughman, Y. Q., Watanabe, M., Cheng, Y., & Rollins, A. M.
- Venue
- Biomedical Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2013-08-13
- Volume
- 4
- Issue
- 9
- Pages
- 1626
- ISSN
- 2156-7085 (ISSN-L)
- OpenAlex
- W1988615695
- Cited by
- 58
- References
- 1
- FWCI
- 4.24
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical pacing of the adult rabbit heart. https://app.cochat.ai/papers/10.1364/boe.4.001626
- The paper
- Jenkins, M. W., Wang, Y. T., Doughman, Y. Q., Watanabe, M., Cheng, Y., & Rollins, A. M. (2013). Optical pacing of the adult rabbit heart. Biomedical Optics Express. https://doi.org/10.1364/boe.4.001626
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.