The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Projection-resolved optical coherence tomographic angiography
Open accessAbstract
Shadowgraphic projection artifacts from superficial vasculature interfere with the visualization of deeper vascular networks in optical coherence tomography angiography (OCT-A). We developed a novel algorithm to remove this artifact by resolving the ambiguity between in situ and projected flow signals. The algorithm identifies voxels with in situ flow as those where intensity-normalized decorrelation values are higher than all shallower voxels in the same axial scan line. This "projection-resolved" (PR) algorithm effectively suppressed the projection artifact on both en face and cross-sectional angiograms and enhanced depth resolution of vascular networks. In the human macula, the enhanced angiograms show three distinct vascular plexuses in the inner retina and no vessels in the outer retina. We demonstrate that PR OCT-A cleanly removes flow projection from the normally avascular outer retinal slab while preserving the density and continuity of the intermediate and deep retinal capillary plexuses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
VII. Note on regression and inheritance in the case of two parents
Pearson, K. (1895) · Proceedings of the Royal Society of London · doi:10.1098/rspl.1895.0041 · Cited by 3,424
Causes and Prevalence of Visual Impairment Among Adults in the UnitedStates
(2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.477 · Cited by 2,616
Split-spectrum amplitude-decorrelation angiography with optical coherence tomography
Jia, Y., Tan, O., Tokayer, J., Potsaid, B., Wang, Y., Liu, J. J., Kraus, M. F., Subhash, H., Fujimoto, J. G., Hornegger, J., et al. (2012) · Optics Express · doi:10.1364/oe.20.004710 · Cited by 1,841
Self-citationA review of optical coherence tomography angiography (OCTA)
de Carlo, T. E., Romano, A., Waheed, N. K., & Duker, J. S. (2015) · International Journal of Retina and Vitreous · doi:10.1186/s40942-015-0005-8 · Cited by 1,126
Age-Related Macular Degeneration and Blindness due to Neovascular Maculopathy
Ferris, F. L., Fine, S. L., & Hyman, L. (1984) · Archives of Ophthalmology · doi:10.1001/archopht.1984.01040031330019 · Cited by 1,093
Jia, Y., Bailey, S. T., Wilson, D. J., Tan, O., Klein, M. L., Flaxel, C. J., Potsaid, B., Liu, J. J., Lu, C. D., Kraus, M. F., et al. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.01.034 · Cited by 729
Self-citationJia, Y., Bailey, S. T., Hwang, T. S., McClintic, S. M., Gao, S. S., Pennesi, M. E., Flaxel, C. J., Lauer, A. K., Wilson, D. J., Hornegger, J., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1500185112 · Cited by 665
Self-citationOptical Coherence Tomography Angiography of the Peripapillary Retina in Glaucoma
Liu, L., Jia, Y., Takusagawa, H. L., Pechauer, A. D., Edmunds, B., Lombardi, L., Davis, E., Morrison, J. C., & Huang, D. (2015) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2015.2225 · Cited by 657
Self-citationThree dimensional optical angiography
Wang, R. K., Jacques, S. L., Ma, Z., Hurst, S., Hanson, S. R., & Gruber, A. (2007) · Optics Express · doi:10.1364/oe.15.004083 · Cited by 627
Pascolini, D., Mariotti, S. P., Pokharel, G. P., Pararajasegaram, R., Etya’ale, D., Négrel, A.-D., & Resnikoff, S. (2004) · Ophthalmic Epidemiology · doi:10.1076/opep.11.2.67.28158 · Cited by 527
Cited by
Optical coherence tomography angiography
Spaide, R. F., Fujimoto, J. G., Waheed, N. K., Sadda, S. R., & Staurenghi, G. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.11.003 · Cited by 1,779
Kashani, A. H., Chen, C.-L., Gahm, J. K., Zheng, F., Richter, G. M., Rosenfeld, P. J., Shi, Y., & Wang, R. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.07.002 · Cited by 1,006
Optical coherence tomography based angiography [Invited]
Chen, C.-L., & Wang, R. K. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001056 · Cited by 415
Samara, W. A., Shahlaee, A., Adam, M. K., Khan, M. A., Chiang, A., Maguire, J. I., Hsu, J., & Ho, A. C. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2016.10.008 · Cited by 345
Laíns, I., Wang, J. C., Cui, Y., Katz, R., Vingopoulos, F., Staurenghi, G., Vavvas, D. G., Miller, J. W., & Miller, J. B. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2021.100951 · Cited by 324
OCT angiography and evaluation of the choroid and choroidal vascular disorders
Borrelli, E., Sarraf, D., Freund, K. B., & Sadda, S. R. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.07.002 · Cited by 321
Sampson, D. M., Gong, P., An, D., Menghini, M., Hansen, A., Mackey, D. A., Sampson, D. D., & Chen, F. K. (2017) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.17-21551 · Cited by 298
Takusagawa, H. L., Liu, L., Ma, K. N., Jia, Y., Gao, S. S., Zhang, M., Edmunds, B., Parikh, M., Tehrani, S., Morrison, J. C., et al. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2017.06.002 · Cited by 290
Self-citation
Metadata
- Authors
- Zhang, M., Hwang, T. S., Campbell, J. P., Bailey, S. T., Wilson, D. J., Huang, D., & Jia, Y.
- Venue
- Biomedical Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2016-02-09
- Volume
- 7
- Issue
- 3
- Pages
- 816
- ISSN
- 2156-7085 (ISSN-L)
- OpenAlex
- W2252774054
- Cited by
- 335
- References
- 27
- FWCI
- 23.86
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.