The DOI matches its Crossref record; 95 of the 95 references it cites were found in a registry or an index.
Polarization sensitive optical coherence tomography – a review [Invited]
Open accessAbstract
Optical coherence tomography (OCT) is now a well-established modality for high-resolution cross-sectional and three-dimensional imaging of transparent and translucent samples and tissues. Conventional, intensity based OCT, however, does not provide a tissue-specific contrast, causing an ambiguity with image interpretation in several cases. Polarization sensitive (PS) OCT draws advantage from the fact that several materials and tissues can change the light's polarization state, adding an additional contrast channel and providing quantitative information. In this paper, we review basic and advanced methods of PS-OCT and demonstrate its use in selected biomedical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
A New Calculus for the Treatment of Optical SystemsI Description and Discussion of the Calculus
Jones, R. C. (1941) · Journal of the Optical Society of America · doi:10.1364/josa.31.000488 · Cited by 1,907
Interpretation of Mueller matrices based on polar decomposition
Lu, S.-Y., & Chipman, R. A. (1996) · Journal of the Optical Society of America A · doi:10.1364/josaa.13.001106 · Cited by 1,409
von Braunmühl, T. (2015) · Der Hautarzt · doi:10.1007/s00105-015-3607-z · Cited by 1,033
de Boer, J. F., Milner, T. E., van Gemert, M. J. C., & Nelson, J. S. (1997) · Optics Letters · doi:10.1364/ol.22.000934 · Cited by 883
Self-citationPolarization-sensitive low-coherence reflectometer for birefringence characterization and ranging
Hee, M. R., Swanson, E. A., Fujimoto, J. G., & Huang, D. (1992) · Journal of the Optical Society of America B · doi:10.1364/josab.9.000903 · Cited by 582
Weinreb, R. N. (1990) · Archives of Ophthalmology · doi:10.1001/archopht.1990.01070060105058 · Cited by 449
Review of polarization sensitive optical coherence tomography and Stokes vector determination
de Boer, J. F., & Milner, T. E. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1483879 · Cited by 440
Self-citationBurn Incidence and Medical Care Use in the United States: Estimates, Trends, and Data Sources
Brigham, P. A., & McLoughlin, E. (1996) · Journal of Burn Care & Rehabilitation · doi:10.1097/00004630-199603000-00003 · Cited by 429
Hitzenberger, C., Goetzinger, E., Sticker, M., Pircher, M., & Fercher, A. (2001) · Optics Express · doi:10.1364/oe.9.000780 · Cited by 391
Self-citation
Cited by
Polarisation optics for biomedical and clinical applications: a review
He, C., He, H., Chang, J., Chen, B., Ma, H., & Booth, M. J. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00639-x · Cited by 604
Optical coherence tomography (OCT): principle and technical realization
Aumann, S., Donner, S., Fischer, J., & Müller, F. (2019) · High Resolution Imaging in Microscopy and Ophthalmology · doi:10.1007/978-3-030-16638-0_3 · Cited by 449
Optical coherence tomography in coronary atherosclerosis assessment and intervention
Araki, M., Park, S.-J., Dauerman, H. L., Uemura, S., Kim, J.-S., Di Mario, C., Johnson, T. W., Guagliumi, G., Kastrati, A., Joner, M., et al. (2022) · Nature Reviews Cardiology · doi:10.1038/s41569-022-00687-9 · Cited by 430
Metadata
- Authors
- de Boer, J. F., Hitzenberger, C. K., & Yasuno, Y.
- Venue
- Biomedical Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2017-02-24
- Volume
- 8
- Issue
- 3
- Pages
- 1838
- ISSN
- 2156-7085 (ISSN-L)
- OpenAlex
- W2590975404
- Cited by
- 454
- References
- 95
- FWCI
- 16.30
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.