Wave-front estimation from wave-front slope measurements
The DOI matches its Crossref record.
Abstract
The problem of wave-front estimation from wave-front slope measurements has been examined from a least-squares curve fitting model point of view. It is shown that the slope measurement sampling geometry influences the model selection for the phase estimation. Successive over-relaxation (SOR) is employed to numerically solve the exact zonal phase estimation problem. A new zonal phase gradient model is introduced and its error propagator, which relates the mean-square wave-front error to the noisy slope measurements, has been compared with two previously used models. A technique for the rapid extraction of phase aperture functions is presented. Error propagation properties for modal estimation are evaluated and compared with zonal estimation results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Supernormal vision and high-resolution retinal imaging through adaptive optics
Liang, J., Williams, D. R., & Miller, D. T. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002884 · Cited by 1,454
Liang, J., Grimm, B., Goelz, S., & Bille, J. F. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.001949 · Cited by 1,195
Aberrations and retinal image quality of the normal human eye
Liang, J., & Williams, D. R. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002873 · Cited by 764
Monochromatic aberrations of the human eye in a large population
Porter, J., Guirao, A., Cox, I. G., & Williams, D. R. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.001793 · Cited by 711
Adaptive optics via pupil segmentation for high-resolution imaging in biological tissues
Ji, N., Milkie, D. E., & Betzig, E. (2010) · Nature Methods · doi:10.1038/nmeth.1411 · Cited by 585
Observing the cell in its native state: Imaging subcellular dynamics in multicellular organisms
Liu, T.-L., Upadhyayula, S., Milkie, D. E., Singh, V., Wang, K., Swinburne, I. A., Mosaliganti, K. R., Collins, Z. M., Hiscock, T. W., Shea, J., et al. (2018) · Science · doi:10.1126/science.aaq1392 · Cited by 570
Rolland, J. P., Davies, M. A., Suleski, T. J., Evans, C., Bauer, A., Lambropoulos, J. C., & Falaggis, K. (2021) · Optica · doi:10.1364/optica.413762 · Cited by 401
Analysis of the performance of the Hartmann–Shack sensor in the human eye
Prieto, P. M., Vargas-Martı́n, F., Goelz, S., & Artal, P. (2000) · Journal of the Optical Society of America A · doi:10.1364/josaa.17.001388 · Cited by 298
Review of phase measuring deflectometry
Huang, L., Idir, M., Zuo, C., & Asundi, A. (2018) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2018.03.026 · Cited by 272
IMI – Clinical Myopia Control Trials and Instrumentation Report
Wolffsohn, J. S., Kollbaum, P. S., Berntsen, D. A., Atchison, D. A., Benavente, A., Bradley, A., Buckhurst, H., Collins, M., Fujikado, T., Hiraoka, T., et al. (2019) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.18-25955 · Cited by 184
“Additionally, as described, refractive power could be obtained based on calculations from the local slope/zonal integration 271 or by calculating the wavefront vergence based on the raw slope measured by the instrument.”
Correction of presbyopia: old problems with old (and new) solutions
Kollbaum, P. S., & Bradley, A. (2020) · Clinical and Experimental Optometry · doi:10.1111/cxo.12987 · Cited by 45
Metadata
- Authors
- Southwell, W. H.
- Venue
- Journal of the Optical Society of America
- Publisher
- Optica Publishing Group
- Published
- 1980-08-01
- Volume
- 70
- Issue
- 8
- Pages
- 998
- ISSN
- 0030-3941 (ISSN-L)
- OpenAlex
- W2003292041
- Cited by
- 985
- References
- 0
- FWCI
- 0.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.