The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Dynamics of the eye’s wave aberration
Abstract
It is well known that the eye's optics exhibit temporal instability in the form of microfluctuations in focus; however, almost nothing is known of the temporal properties of the eye's other aberrations. We constructed a real-time Hartmann-Shack (HS) wave-front sensor to measure these dynamics at frequencies as high as 60 Hz. To reduce spatial inhomogeneities in the short-exposure HS images, we used a low-coherence source and a scanning system. HS images were collected on three normal subjects with natural and paralyzed accommodation. Average temporal power spectra were computed for the wave-front rms, the Seidel aberrations, and each of 32 Zernike coefficients. The results indicate the presence of fluctuations in all of the eye's aberration, not just defocus. Fluctuations in higher-order aberrations share similar spectra and bandwidths both within and between subjects, dropping at a rate of approximately 4 dB per octave in temporal frequency. The spectrum shape for higher-order aberrations is generally different from that for microfluctuations of accommodation. The origin of these measured fluctuations is not known, and both corneal/lenticular and retinal causes are considered. Under the assumption that they are purely corneal or lenticular, calculations suggest that a perfect adaptive optics system with a closed-loop bandwidth of 1-2 Hz could correct these aberrations well enough to achieve diffraction-limited imaging over a dilated pupil.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251
Zernike polynomials and atmospheric turbulence*
Noll, R. J. (1976) · Journal of the Optical Society of America · doi:10.1364/josa.66.000207 · Cited by 2,771
Supernormal vision and high-resolution retinal imaging through adaptive optics
Liang, J., Williams, D. R., & Miller, D. T. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002884 · Cited by 1,454
Self-citationLiang, J., Grimm, B., Goelz, S., & Bille, J. F. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.001949 · Cited by 1,195
The arrangement of the three cone classes in the living human eye
Roorda, A., & Williams, D. R. (1999) · Nature · doi:10.1038/17383 · Cited by 982
Self-citationAberrations and retinal image quality of the normal human eye
Liang, J., & Williams, D. R. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002873 · Cited by 764
Self-citationA subjective method for the measurement of monochromatic* aberrations of the eye
Howland, H. C., & Howland, B. (1977) · Journal of the Optical Society of America · doi:10.1364/josa.67.001508 · Cited by 379
Eye-movements and visual perception
Ditchburn, R. W. (1973) · Cited by 335
Fluctuations in accommodation: a review
Charman, W. N., & Heron, G. (1988) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.1988.tb01031.x · Cited by 262
Vargas-Martı́n, F., Prieto, P. M., & Artal, P. (1998) · Journal of the Optical Society of America A · doi:10.1364/josaa.15.002552 · Cited by 163
Self-citation
Cited by
Neural compensation for the eye’s optical aberrations
Artal, P., Chen, L., Fernández, E. J., Singer, B., Manzanera, S., & Williams, D. R. (2004) · Journal of Vision · doi:10.1167/4.4.4 · Cited by 332
Self-citationGuirao, A., Williams, D. R., & Cox, I. G. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.001003 · Cited by 292
Self-citationRapid adaptive optical recovery of optimal resolution over large volumes
Wang, K., Milkie, D. E., Saxena, A., Engerer, P., Misgeld, T., Bronner, M. E., Mumm, J., & Betzig, E. (2014) · Nature Methods · doi:10.1038/nmeth.2925 · Cited by 271
Adaptive optics retinal imaging reveals S-cone dystrophy in tritan color vision deficiency
Baraas, R. C., Carroll, J., Gunther, K. L., Chung, M., Williams, D. R., Foster, D. H., & Neitz, M. (2007) · Journal of the Optical Society of America A · doi:10.1364/josaa.24.001438 · Cited by 100
Self-citationWave-aberration control with a liquid crystal on silicon (LCOS) spatial phase modulator
Fernández, E. J., Prieto, P. M., & Artal, P. (2009) · Optics Express · doi:10.1364/oe.17.011013 · Cited by 57
Self-citation
Metadata
- Authors
- Hofer, H., Artal, P., Singer, B., Aragón, J. L., & Williams, D. R.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 2001-03-01
- Volume
- 18
- Issue
- 3
- Pages
- 497
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2128542405
- Cited by
- 353
- References
- 11
- FWCI
- 12.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamics of the eye’s wave aberration. https://app.cochat.ai/papers/10.1364/josaa.18.000497
- The paper
- Hofer, H., Artal, P., Singer, B., Aragón, J. L., & Williams, D. R. (2001). Dynamics of the eye’s wave aberration. Journal of the Optical Society of America A. https://doi.org/10.1364/josaa.18.000497
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.