The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Monochromatic aberrations of the human eye in a large population
Abstract
From both a fundamental and a clinical point of view, it is necessary to know the distribution of the eye's aberrations in the normal population and to be able to describe them as efficiently as possible. We used a modified Hartmann-Shack wave-front sensor to measure the monochromatic wave aberration of both eyes for 109 normal human subjects across a 5.7-mm pupil. We analyzed the distribution of the eye's aberrations in the population and found that most Zernike modes are relatively uncorrelated with each other across the population. A principal components analysis was applied to our wave-aberration measurements with the resulting principal components providing only a slightly more compact description of the population data than Zernike modes. This indicates that Zernike modes are efficient basis functions for describing the eye's wave aberration. Even though there appears to be a random variation in the eye's aberrations from subject to subject, many aberrations in the left eye were found to be significantly correlated with their counterparts in the right eye.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251
Zernike polynomials and atmospheric turbulence*
Noll, R. J. (1976) · Journal of the Optical Society of America · doi:10.1364/josa.66.000207 · Cited by 2,771
Dunteman, G. (1989) · Sage eBooks · doi:10.4135/9781412985475 · Cited by 2,658
Supernormal vision and high-resolution retinal imaging through adaptive optics
Liang, J., Williams, D. R., & Miller, D. T. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002884 · Cited by 1,454
Self-citationLiang, J., Grimm, B., Goelz, S., & Bille, J. F. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.001949 · Cited by 1,195
Wave-front estimation from wave-front slope measurements
Southwell, W. H. (1980) · Journal of the Optical Society of America · doi:10.1364/josa.70.000998 · Cited by 985
Standards for Reporting the Optical Aberrations of Eyes
Thibos, L. N., Applegate, R. A., Schwiegerling, J. T., Webb, R., & Members, V. S. T. (2000) · Vision Science and its Applications · doi:10.1364/vsia.2000.suc1 · Cited by 824
Aberrations and retinal image quality of the normal human eye
Liang, J., & Williams, D. R. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002873 · Cited by 764
Self-citationPrevalence of Myopia in the United States
Sperduto, R. D., Seigel, D., Roberts, J., & Rowland, M. (1983) · Archives of Ophthalmology · doi:10.1001/archopht.1983.01040010405011 · Cited by 569
Finger Prints, Palms and Soles: an Introduction to Dermatoglyphics.
(1944) · Archives of Pediatrics & Adolescent Medicine · doi:10.1001/archpedi.1944.02020110063021 · Cited by 541
Cited by
Adaptive optics scanning laser ophthalmoscopy
Roorda, A., Romero-Borja, F., Donnelly III, W. J., Queener, H., Hebert, T. J., & Campbell, M. C. W. (2002) · Optics Express · doi:10.1364/oe.10.000405 · Cited by 967
Thibos, L. N., Hong, X., Bradley, A., & Cheng, X. (2002) · Journal of the Optical Society of America A · doi:10.1364/josaa.19.002329 · Cited by 622
Optical aberrations of the human anterior cornea
Wang, L., Dai, E., Koch, D. D., & Nathoo, A. (2003) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(03)00467-x · Cited by 361
Metrics of optical quality derived from wave aberrations predict visual performance
Marsack, J. D., Thibos, L. N., & Applegate, R. A. (2004) · Journal of Vision · doi:10.1167/4.4.8 · Cited by 341
Accommodative Lag before and after the Onset of Myopia
Mutti, D. O., Mitchell, G. L., Hayes, J. R., Jones, L. A., Moeschberger, M. L., Cotter, S. A., Kleinstein, R. N., Manny, R. E., Twelker, J. D., & Zadnik, K. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-0888 · Cited by 299
Adaptive optics for high-resolution imaging
Hampson, K. M., Turcotte, R., Miller, D. T., Kurokawa, K., Males, J. R., Ji, N., & Booth, M. J. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00066-7 · Cited by 291
Predicting subjective judgment of best focus with objective image quality metrics
Cheng, X., Bradley, A., & Thibos, L. N. (2004) · Journal of Vision · doi:10.1167/4.4.7 · Cited by 255
Power profiles of multifocal contact lenses and their interpretation
Plainis, S., Atchison, D. A., & Charman, W. N. (2013) · Optometry and Vision Science · doi:10.1097/opx.0000000000000030 · Cited by 115
Optical quality of emmetropic and myopic eyes in the periphery measured with high-angular resolution
Jaeken, B., & Artal, P. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8993 · Cited by 75
Myopia and peripheral ocular aberrations
Mathur, A., Atchison, D. A., & Charman, W. N. (2009) · Journal of Vision · doi:10.1167/9.10.15 · Cited by 53
Metadata
- Authors
- Porter, J., Guirao, A., Cox, I. G., & Williams, D. R.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 2001-08-01
- Volume
- 18
- Issue
- 8
- Pages
- 1793
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2147143800
- Cited by
- 711
- References
- 18
- FWCI
- 17.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.