The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Saturated patterned excitation microscopy—a concept for optical resolution improvement
Open accessAbstract
The resolution of optical microscopy is limited by the numerical aperture and the wavelength of light. Many strategies for improving resolution such as 4Pi and I5M have focused on an increase of the numerical aperture. Other approaches have based resolution improvement in fluorescence microscopy on the establishment of a nonlinear relationship between local excitation light intensity in the sample and in the emitted light. However, despite their innovative character, current techniques such as stimulated emission depletion (STED) and ground-state depletion (GSD) microscopy require complex optical configurations and instrumentation to narrow the point-spread function. We develop the theory of nonlinear patterned excitation microscopy for achieving a substantial improvement in resolution by deliberate saturation of the fluorophore excited state. The postacquisition manipulation of the acquired data is computationally more complex than in STED or GSD, but the experimental requirements are simple. Simulations comparing saturated patterned excitation microscopy with linear patterned excitation microscopy (also referred to in the literature as structured illumination or harmonic excitation light microscopy) and ordinary widefield microscopy are presented and discussed. The effects of photon noise are included in the simulations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Hell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
Габор, Д. (1946) · Journal of the IEE · Cited by 5,036
Gustafsson, M. G. L. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00710.x · Cited by 3,786
Fluorescence microscopy with diffraction resolution barrier broken by stimulated emission
Klar, T. A., Jakobs, S., Dyba, M., Egner, A., & Hell, S. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.15.8206 · Cited by 1,869
Method of obtaining optical sectioning by using structured light in a conventional microscope
Neil, M. A. A., Juškaitis, R., & Wilson, T. (1997) · Optics Letters · doi:10.1364/ol.22.001905 · Cited by 1,143
Laterally modulated excitation microscopy: improvement of resolution by using a diffraction grating:
Heintzmann, R., & Cremer, C. G. (1999) · SPIE Proceedings · doi:10.1117/12.336833 · Cited by 589
Self-citationHell, S. W., & Kroug, M. (1995) · Applied Physics B Lasers and Optics · doi:10.1007/bf01081333 · Cited by 532
I5M: 3D widefield light microscopy with better than 100 nm axial resolution
Gustafsson, Agard, & Sedat (1999) · Journal of Microscopy · doi:10.1046/j.1365-2818.1999.00576.x · Cited by 417
True optical resolution beyond the Rayleigh limit achieved by standing wave illumination
Frohn, J., Knapp, H. F., & Stemmer, A. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.130181797 · Cited by 240
Fluorophores for Confocal Microscopy
Tsien, R. Y., & Waggoner, A. S. (1995) · Springer eBooks · doi:10.1007/978-1-4757-5348-6_16 · Cited by 172
Far‐field fluorescence microscopy with three‐dimensional resolution in the 100‐nm range
Hell, S. W., Schrader, M., & van der Voort, H. T. M. (1997) · Journal of Microscopy · doi:10.1046/j.1365-2818.1997.2410797.x · Cited by 140
Quantitative Fluorescence Confocal Laser Scanning Microscopy (CLSM)
Sandison, D. R., Williams, R. M., Wells, K. S., Strickler, J. H., & Webb, W. W. (1995) · Springer eBooks · doi:10.1007/978-1-4757-5348-6_3 · Cited by 95
Analysis of the limit to superresolution in incoherent imaging
Sementilli, P. J., Hunt, B. R., & Nadar, M. S. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.002265 · Cited by 85
Castellanos-Guzmån, A. G., Campa-Molina, J., & Reyes-Gómez, J. (1997) · Journal of Microscopy · doi:10.1046/j.1365-2818.1997.1350693.x · Cited by 33
Cited by
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
“SPEM/SSIM [71, 72] differs from GSD or STED in that it confines the dark state B rather than the bright state A (Fig.”
BackgroundGustafsson, M. G. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406877102 · Cited by 2,224
Jares-Erijman, E. A., & Jovin, T. M. (2003) · Nature Biotechnology · doi:10.1038/nbt896 · Cited by 1,824
Self-citationGustafsson, M. G. L., Shao, L., Carlton, P. M., Wang, C. J. R., Golubovskaya, I. N., Cande, W. Z., Agard, D. A., & Sedat, J. W. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.120345 · Cited by 1,557
Fluorescent probes for super-resolution imaging in living cells
Fernández-Suárez, M., & Ting, A. Y. (2008) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2531 · Cited by 1,306
Metadata
- Authors
- Heintzmann, R., Jovin, T. M., & Cremer, C.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 2002-08-01
- Volume
- 19
- Issue
- 8
- Pages
- 1599
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2053697885
- Cited by
- 566
- References
- 15
- FWCI
- 5.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.