The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Adaptive optics scanning laser ophthalmoscopy
Open accessAbstract
We present the first scanning laser ophthalmoscope that uses adaptive optics to measure and correct the high order aberrations of the human eye. Adaptive optics increases both lateral and axial resolution, permitting axial sectioning of retinal tissue in vivo. The instrument is used to visualize photoreceptors, nerve fibers and flow of white blood cells in retinal capillaries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook Of Biological Confocal Microscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-45524-2 · Cited by 3,637
Supernormal vision and high-resolution retinal imaging through adaptive optics
Liang, J., Williams, D. R., & Miller, D. T. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002884 · Cited by 1,454
The arrangement of the three cone classes in the living human eye
Roorda, A., & Williams, D. R. (1999) · Nature · doi:10.1038/17383 · Cited by 982
Self-citationMonochromatic aberrations of the human eye in a large population
Porter, J., Guirao, A., Cox, I. G., & Williams, D. R. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.001793 · Cited by 711
Confocal scanning laser ophthalmoscope
Webb, R. H., Hughes, G. W., & Delori, F. C. (1987) · Applied Optics · doi:10.1364/ao.26.001492 · Cited by 597
Dynamics of the eye’s wave aberration
Hofer, H., Artal, P., Singer, B., Aragón, J. L., & Williams, D. R. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.000497 · Cited by 353
Webb, R. H., Hughes, G. W., & Pomerantzeff, O. (1980) · Applied Optics · doi:10.1364/ao.19.002991 · Cited by 272
Topography of the foveal cone mosaic in the living human eye
Williams, D. R. (1988) · Vision Research · doi:10.1016/0042-6989(88)90185-x · Cited by 159
The Role of the Pinhole in Confocal Imaging Systems
Wilson, T. (1990) · Springer eBooks · doi:10.1007/978-1-4615-7133-9_11 · Cited by 103
Contrast improvement of confocal retinal imaging by use of phase-correcting plates
Burns, S. A., Marcos, S. C., Elsner, A. E., & Bará, S. (2002) · Optics Letters · doi:10.1364/ol.27.000400 · Cited by 54
Cited by
State-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906
Charbel Issa, P., Gillies, M. C., Chew, E. Y., Bird, A. C., Heeren, T. F. C., Peto, T., Holz, F. G., & Scholl, H. P. N. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2012.11.002 · Cited by 393
In Vivo Imaging of Human Cone Photoreceptor Inner Segments
Scoles, D., Sulai, Y. N., Langlo, C. S., Fishman, G. A., Curcio, C. A., Carroll, J., & Dubra, A. (2014) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.14-14542 · Cited by 380
Adaptive-optics ultrahigh-resolution optical coherence tomography
Hermann, B., Fernández, E. J., Unterhuber, A., Sattmann, H., Fercher, A. F., Drexler, W., Prieto, P. M., & Artal, P. (2004) · Optics Letters · doi:10.1364/ol.29.002142 · Cited by 379
Potsaid, B., Gorczynska, I., Srinivasan, V. J., Chen, Y., Jiang, J., Cable, A., & Fujimoto, J. G. (2008) · Optics Express · doi:10.1364/oe.16.015149 · Cited by 372
Metadata
- Authors
- Roorda, A., Romero-Borja, F., Donnelly III, W. J., Queener, H., Hebert, T. J., & Campbell, M. C. W.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2002-05-06
- Volume
- 10
- Issue
- 9
- Pages
- 405
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W1987146434
- Cited by
- 967
- References
- 10
- FWCI
- 11.64
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.