The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Adaptive-optics ultrahigh-resolution optical coherence tomography
Abstract
Merging of ultrahigh-resolution optical coherence tomography (UHR OCT) and adaptive optics (AO), resulting in high axial (3 microm) and improved transverse resolution (5-10 microm) is demonstrated for the first time to our knowledge in in vivo retinal imaging. A compact (300 mm x 300 mm) closed-loop AO system, based on a real-time Hartmann-Shack wave-front sensor operating at 30 Hz and a 37-actuator membrane deformable mirror, is interfaced to an UHR OCT system, based on a commercial OCT instrument, employing a compact Ti:sapphire laser with 130-nm bandwidth. Closed-loop correction of both ocular and system aberrations results in a residual uncorrected wave-front rms of 0.1 microm for a 3.68-mm pupil diameter. When this level of correction is achieved, OCT images are obtained under a static mirror configuration. By use of AO, an improvement of the transverse resolution of two to three times, compared with UHR OCT systems used so far, is obtained. A significant signal-to-noise ratio improvement of up to 9 dB in corrected compared with uncorrected OCT tomograms is also achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Supernormal vision and high-resolution retinal imaging through adaptive optics
Liang, J., Williams, D. R., & Miller, D. T. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002884 · Cited by 1,454
Adaptive optics scanning laser ophthalmoscopy
Roorda, A., Romero-Borja, F., Donnelly III, W. J., Queener, H., Hebert, T. J., & Campbell, M. C. W. (2002) · Optics Express · doi:10.1364/oe.10.000405 · Cited by 967
Ultrahigh-resolution ophthalmic optical coherence tomography
Drexler, W., Morgner, U., Ghanta, R. K., Kärtner, F. X., Schuman, J. S., & Fujimoto, J. G. (2001) · Nature Medicine · doi:10.1038/86589 · Cited by 962
Self-citationIn vivo ultrahigh-resolution optical coherence tomography
Drexler, W., Morgner, U., Käertner, F. X., Pitris, C., Boppart, S. A., Li, X. D., Ippen, E. P., & Fujimoto, J. G. (1999) · Optics Letters · doi:10.1364/ol.24.001221 · Cited by 945
Self-citationUltrahigh-resolution optical coherence tomography
Drexler, W. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1629679 · Cited by 553
Self-citationCompensation of corneal aberrations by the internal optics in the human eye
Artal, P., Guirao, A., Berrio, E., & Williams, D. R. (2001) · Journal of Vision · doi:10.1167/1.1.1 · Cited by 434
Self-citationVargas-Martı́n, F., Prieto, P. M., & Artal, P. (1998) · Journal of the Optical Society of America A · doi:10.1364/josaa.15.002552 · Cited by 163
Self-citationMembrane deformable mirror for adaptive optics: performance limits in visual optics
Fernández, E. J., & Artal, P. (2003) · Optics Express · doi:10.1364/oe.11.001056 · Cited by 160
Self-citation
Cited by
State-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906
Self-citationOptical Coherence Tomography: History, Current Status, and Laboratory Work
Gabriele, M. L., Wollstein, G., Ishikawa, H., Kagemann, L., Xu, J., Folio, L. S., & Schuman, J. S. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6312 · Cited by 310
Contemporary retinal imaging techniques in diabetic retinopathy: a review
Cole, E. D., Novais, E. A., Louzada, R. N., & Waheed, N. K. (2016) · Clinical & Experimental Ophthalmology · doi:10.1111/ceo.12711 · Cited by 91
Syndromic retinitis pigmentosa.
Karuntu, J. S., Almushattat, H., Nguyen, X.-T.-A., Plomp, A. S., Wanders, R. J. A., Hoyng, C. B., van Schooneveld, M. J., Schalij-Delfos, N. E., Brands, M. M., Leroy, B. P., et al. (2025) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2024.101324 · Cited by 39
Femtosecond laser processing with adaptive optics based on convolutional neural network
Hasegawa, S., & Hayasaki, Y. (2021) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2021.106563 · Cited by 26
Metadata
- Authors
- Hermann, B., Fernández, E. J., Unterhuber, A., Sattmann, H., Fercher, A. F., Drexler, W., Prieto, P. M., & Artal, P.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2004-09-15
- Volume
- 29
- Issue
- 18
- Pages
- 2142
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W1983059581
- Cited by
- 379
- References
- 9
- FWCI
- 14.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adaptive-optics ultrahigh-resolution optical coherence tomography. https://app.cochat.ai/papers/10.1364/ol.29.002142
- The paper
- Hermann, B., Fernández, E. J., Unterhuber, A., Sattmann, H., Fercher, A. F., Drexler, W., Prieto, P. M., & Artal, P. (2004). Adaptive-optics ultrahigh-resolution optical coherence tomography. Optics Letters. https://doi.org/10.1364/ol.29.002142
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.