The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
Open accessAbstract
We present theoretical and experimental results which demonstrate the superior sensitivity of swept source (SS) and Fourier domain (FD) optical coherence tomography (OCT) techniques over the conventional time domain (TD) approach. We show that SS- and FD-OCT have equivalent expressions for system signal-to-noise ratio which result in a typical sensitivity advantage of 20-30dB over TD-OCT. Experimental verification is provided using two novel spectral discrimination (SD) OCT systems: a differential fiber-based 800nm FD-OCT system which employs deep-well photodiode arrays, and a differential 1300nm SS-OCT system based on a swept laser with an 87nm tuning range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Performance of fourier domain vs time domain optical coherence tomography
Leitgeb, R., Hitzenberger, C., & Fercher, A. (2003) · Optics Express · doi:10.1364/oe.11.000889 · Cited by 1,854
Measurement of intraocular distances by backscattering spectral interferometry
Fercher, A. F., Hitzenberger, C. K., Kamp, G., & El-Zaiat, S. Y. (1995) · Optics Communications · doi:10.1016/0030-4018(95)00119-s · Cited by 1,212
In vivo human retinal imaging by Fourier domain optical coherence tomography
Wojtkowski, M., Leitgeb, R., Kowalczyk, A., Bajraszewski, T., & Fercher, A. F. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1482379 · Cited by 913
Spectral resolution and sampling issues in Fourier-transform spectral interferometry
Dorrer, C., Belabas, N., Likforman, J.-P., & Joffre, M. (2000) · Journal of the Optical Society of America B · doi:10.1364/josab.17.001795 · Cited by 364
Wavelength-tuning interferometry of intraocular distances
Lexer, F., Hitzenberger, C. K., Fercher, A. F., & Kulhavy, M. (1997) · Applied Optics · doi:10.1364/ao.36.006548 · Cited by 182
Cited by
Split-spectrum amplitude-decorrelation angiography with optical coherence tomography
Jia, Y., Tan, O., Tokayer, J., Potsaid, B., Wang, Y., Liu, J. J., Kraus, M. F., Subhash, H., Fujimoto, J. G., Hornegger, J., et al. (2012) · Optics Express · doi:10.1364/oe.20.004710 · Cited by 1,841
Optical coherence tomography angiography
Spaide, R. F., Fujimoto, J. G., Waheed, N. K., Sadda, S. R., & Staurenghi, G. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.11.003 · Cited by 1,779
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Wojtkowski, M., Srinivasan, V. J., Ko, T. H., Fujimoto, J. G., Kowalczyk, A., & Duker, J. S. (2004) · Optics Express · doi:10.1364/opex.12.002404 · Cited by 1,022
Kashani, A. H., Chen, C.-L., Gahm, J. K., Zheng, F., Richter, G. M., Rosenfeld, P. J., Shi, Y., & Wang, R. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.07.002 · Cited by 1,006
Metadata
- Authors
- Choma, M., Sarunic, M., Yang, C., & Izatt, J.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2003-09-08
- Volume
- 11
- Issue
- 18
- Pages
- 2183
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2097371977
- Cited by
- 1,794
- References
- 6
- FWCI
- 36.64
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.