Cited by 124Optical measurement and interference techniquesDigital Holography and MicroscopyOptical Coherence Tomography Applications

The DOI matches its Crossref record; 9 of the 11 references it cites were found in a registry or an index.

Simultaneous measurement of refractive index and thickness by combining low-coherence interferometry and confocal optics

Open access

Abstract

We propose and demonstrate novel methods that enable simultaneous measurements of the phase index, the group index, and the geometrical thickness of an optically transparent object by combining optical low-coherence interferometer and confocal optics. The low-coherence interferometer gives information relating the group index with the thickness, while the confocal optics allows access to the phase index related with the thickness of the sample. To relate these, two novel methods were devised. In the first method, the dispersion-induced broadening of the low-coherence envelop signal was utilized, and in the second method the frequency derivative of the phase index was directly obtained by taking the confocal measurements at several wavelengths. The measurements were made with eight different samples; B270, CaF2, two of BK7, two of fused silica, cover glass, and cigarette cover film. The average measurement errors of the first and the second methods were 0.123% and 0.061% in the geometrical thickness, 0.133% and 0.066% in the phase index, and 0.106% and 0.057% in the group index, respectively.

Overview

Integrity signals

Registry

Crossref · 10.1364/oe.16.005516

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 11 references

Cited by

See all 124

Metadata

Authors
Kim, S., Na, J., Kim, M. J., & Lee, B. H.
Affiliations
Gwangju Institute of Science and Technology (KR)
Venue
Optics Express
Published
2008-04-04
Volume
16
Issue
8
Pages
5516
ISSN
1094-4087 (ISSN-L)
OpenAlex
W2151863407
Cited by
123
References
11
Citations by year
2026: 2 · 2025: 4 · 2024: 6 · 2023: 6 · 2022: 6 · 2021: 7 · 2020: 6 · 2019: 10 · 2018: 9 · 2017: 13 · 2016: 4 · 2015: 11 · 2014: 8 · 2013: 13 · 2012: 4
FWCI
6.71
Type
journal article
Language
en
Open access
Locations
  • Optics Express (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Optical measurement and interference techniques
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Digital Holography and Microscopy
  • Physical Sciences › Engineering › Biomedical Engineering › Optical Coherence Tomography Applications
Keywords
refractive index measurement, optical thickness measurement, low-coherence interferometry, group index, simultaneous measurement, transparent objects
MeSH terms
Computer Simulation, Equipment Design, Interferometry, Lenses, Materials Testing, Models, Theoretical, Refractometry, Computer-Aided Design, Microscopy, Confocal, Equipment Failure Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simultaneous measurement of refractive index and thickness by combining low-coherence interferometry and confocal optics. https://app.cochat.ai/papers/10.1364/oe.16.005516
The paper
Kim, S., Na, J., Kim, M. J., & Lee, B. H. (2008). Simultaneous measurement of refractive index and thickness by combining low-coherence interferometry and confocal optics. Optics Express. https://doi.org/10.1364/oe.16.005516