The DOI matches its Crossref record; 9 of the 11 references it cites were found in a registry or an index.
Simultaneous measurement of refractive index and thickness by combining low-coherence interferometry and confocal optics
Open accessAbstract
We propose and demonstrate novel methods that enable simultaneous measurements of the phase index, the group index, and the geometrical thickness of an optically transparent object by combining optical low-coherence interferometer and confocal optics. The low-coherence interferometer gives information relating the group index with the thickness, while the confocal optics allows access to the phase index related with the thickness of the sample. To relate these, two novel methods were devised. In the first method, the dispersion-induced broadening of the low-coherence envelop signal was utilized, and in the second method the frequency derivative of the phase index was directly obtained by taking the confocal measurements at several wavelengths. The measurements were made with eight different samples; B270, CaF2, two of BK7, two of fused silica, cover glass, and cigarette cover film. The average measurement errors of the first and the second methods were 0.123% and 0.061% in the geometrical thickness, 0.133% and 0.066% in the phase index, and 0.106% and 0.057% in the group index, respectively.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Fukano, T., & Yamaguchi, I. (1996) · Optics Letters · doi:10.1364/ol.21.001942 · Cited by 118
Maruyama, H., Inoue, S., Mitsuyama, T., Ohmi, M., & Haruna, M. (2002) · Applied Optics · doi:10.1364/ao.41.001315 · Cited by 88
Ohmi, M., Ohnishi, Y., Yoden, K., & Haruna, M. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.867961 · Cited by 88
Fukano, T., & Yamaguchi, I. (1999) · Applied Optics · doi:10.1364/ao.38.004065 · Cited by 74
Wang, X., Zhang, C., Zhang, L., Xue, L., & Tian, J. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1501887 · Cited by 66
Refractive index tomography of turbid media by bifocal optical coherence refractometry
Zvyagin, A. V., Silva, D., Alexandrov, S., Hillman, T. R., Armstrong, J. J., Tsuzuki, T., & Sampson, D. D. (2003) · Optics Express · doi:10.1364/oe.11.003503 · Cited by 64
Bifocal optical coherenc refractometry of turbid media
Alexandrov, S., Zvyagin, A. V., Silva, D., & Sampson, D. D. (2003) · Optics Letters · doi:10.1364/ol.28.000117 · Cited by 32
Ohmi, M., Nishi, H., Konishi, Y., Yamada, Y., & Haruna, M. (2004) · Measurement Science and Technology · doi:10.1088/0957-0233/15/8/017 · Cited by 31
Maruyama, H., Mitsuyama, T., Ohmi, M., & Haruna, M. (2000) · Optical Review · doi:10.1007/s10043-000-0468-0 · Cited by 24
Cited by
Items 101–124 of 124
Dong, J., Ji, F., Xia, H. J., Liu, Z. J., Zhang, T., & Yang, L. (2017) · Measurement Science and Technology · doi:10.1088/1361-6501/aa96e4 · Cited by 1
Boettcher, T., & Osten, W. (2018) · tm - Technisches Messen · doi:10.1515/teme-2017-0134 · Cited by 1
Park, J., Bae, J., & Jin, J. (2019) · Optical Measurement Systems for Industrial Inspection XI · doi:10.1117/12.2525970 · Cited by 1
Na, J., Choi, W. J., Choi, H. Y., Ryu, S. Y., Choi, E. S., & Lee, B. H. (2009) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.808971 · Cited by 1
Self-citationRajai, P. (2016) · uO Research (University of Ottawa) · doi:10.20381/ruor-6066 · Cited by 1
Characterization of Higher Order Modes in Optical Fibers
Ma, Y. (2009) · OPUS FAU (Kooperativer Bibliotheksverbund Berlin-Brandenburg (KOBV), on behalf of the Universitätsbibliothek Erlangen-Nürnberg) · Cited by 1
Yao, J., Meemon, P., Huang, J., Head, S. T., & Rolland, J. P. (2013) · doi:10.1364/sumsession.2013.th9
Na, J., Choi, H. Y., Lee, C., & Lee, B. H. (2009) · Opto-Electronics and Communications Conference (OECC) · doi:10.1109/oecc.2009.5222717
Self-citationSimultaneous measurement of refractive index and thickness with a convergent beam
Hii, K. U., & Kwek, K. H. (2014) · Optical Review · doi:10.1007/s10043-014-0114-x
Measurement of the thickness of the lens with the use of all fiber low-coherence interferometer
Jóźwik, M., Stępień, K., Lipiński, S., Budnicki, D., Napierała, M., & Nasiłowski, T. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2225066
Geometrical Thickness Measurement of Thin Films by a Transmitted Gaussian Beam
Cywiak, M., Olvera-R, O., & Cervantes-L, J. (2016) · Conference proceedings of the Society for Experimental Mechanics · doi:10.1007/978-3-319-28513-9_18
Pongchalee, P., Meemon, P., & Widjaja, J. (2017) · Biomedical Engineering International Conference · doi:10.1109/bmeicon.2017.8229124
Temperature effects upon a multicore optical fibre curvature sensor
Papachristou, N., Morton, J. A. S., Carter, R., Maier, R. R. J., & MacPherson, W. N. (2017) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2017.8234257
Kim, Y., Sugita, N., & Mitsuishi, M. (2018) · Laser applications in microelectronic and optoelectronic manufacturing. Conference · doi:10.1117/12.2287641
Francis, D., Ford, H. D., & Tatam, R. P. (2018) · Optical Sensing and Detection · doi:10.1117/12.2306391
Dong, J., & Lu, R. (2018) · Journal of Applied Physics · doi:10.1063/1.5018209
Index of refraction estimation using dual-angle optical coherence tomography
Pitris, C., & Photiou, C. (2019) · Optical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine · doi:10.1117/12.2510925
Tanaka, T., & Kawai, K. (2025) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/adfd66
Performance of low-coherence and confocal refractometry with reduced index contrast
Francis, D., Hallam, J. M., & Tatam, R. P. (2025) · Optics Express · doi:10.1364/oe.582088
Zhou, G., Bai, Y., Xie, S., & Dong, B. (2026) · Optics Letters · doi:10.1364/ol.588564
Spatio-temporal ultrafast laser tailoring for bulk functionalization of transparent materials
Mauclair, C. (2010) · theses.fr (ABES) · doi:10.70675/47cb348czf24dz4ef9z92c4zc7c72eec0f48
Non-Contact Refractive Index Measurement of Liquid Samples Using Low Coherence Interferometry
Atanasovska, M., Joža, A. V., & Bajić, J. S. (2026) · International Symposium INFOTEH-JAHORINA (INFOTEH) · doi:10.1109/infoteh68759.2026.11477723
Ren, J., Wei, X., Lu, C., Li, Q., & Zheng, K. (2026) · Journal of Biomedical Optics · doi:10.1117/1.jbo.31.8.086003
Metadata
- Authors
- Kim, S., Na, J., Kim, M. J., & Lee, B. H.
- Affiliations
- Gwangju Institute of Science and Technology (KR)
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2008-04-04
- Volume
- 16
- Issue
- 8
- Pages
- 5516
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2151863407
- Cited by
- 123
- References
- 11
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 6 · 2023: 6 · 2022: 6 · 2021: 7 · 2020: 6 · 2019: 10 · 2018: 9 · 2017: 13 · 2016: 4 · 2015: 11 · 2014: 8 · 2013: 13 · 2012: 4
- FWCI
- 6.71
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Optics Express (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Optical measurement and interference techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Digital Holography and Microscopy
- Physical Sciences › Engineering › Biomedical Engineering › Optical Coherence Tomography Applications
- Keywords
- refractive index measurement, optical thickness measurement, low-coherence interferometry, group index, simultaneous measurement, transparent objects
- MeSH terms
- Computer Simulation, Equipment Design, Interferometry, Lenses, Materials Testing, Models, Theoretical, Refractometry, Computer-Aided Design, Microscopy, Confocal, Equipment Failure Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review