Quasi-near field terahertz generation and detection
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
We describe a simple terahertz (THz) time domain spectrometer with a bandwidth extending up to 7.5 THz. We show that by keeping the generation and detection crystals close to each other a high signal-to-noise ratio (SNR) can be achieved without using lock-in detection and dry nitrogen flushing. The observed spectra show very good agreement with the spectra calculated based on a simple model which includes phase matching and absorption in the generation and detection crystals. Using this set-up we have measured the absorption lines in D-tartaric acid from 0.5 THz up to 7 THz. We show that the high frequency region > 3 THz is the better choice to measure small changes in the water content of a hygroscopic sample compared to the low frequency region.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Far-infrared time-domain spectroscopy with terahertz beams of dielectrics and semiconductors
Grischkowsky, D., Keiding, S., van Exter, M., & Fattinger, C. (1990) · Journal of the Optical Society of America B · doi:10.1364/josab.7.002006 · Cited by 2,239
Free-space electro-optic sampling of terahertz beams
Wu, Q., & Zhang, X.-C. (1995) · Applied Physics Letters · doi:10.1063/1.114909 · Cited by 993
Terahertz time-domain spectroscopy of water vapor
van Exter, M., Fattinger, C., & Grischkowsky, D. (1989) · Optics Letters · doi:10.1364/ol.14.001128 · Cited by 862
Detectors and sources for ultrabroadband electro-optic sampling: Experiment and theory
Leitenstorfer, A., Hunsche, S., Shah, J., Nuss, M. C., & Knox, W. H. (1999) · Applied Physics Letters · doi:10.1063/1.123601 · Cited by 461
Gas sensing using terahertz time-domain spectroscopy
Mittleman, D. M., Jacobsen, R. H., Neelamani, R., Baraniuk, R. G., & Nuss, M. C. (1998) · Applied Physics B: Lasers and Optics · doi:10.1007/s003400050520 · Cited by 379
Chemical recognition in terahertz time-domain spectroscopy and imaging
Fischer, B., Hoffmann, M., Helm, H., Modjesch, G., & Jepsen, P. U. (2005) · Semiconductor Science and Technology · doi:10.1088/0268-1242/20/7/015 · Cited by 288
Cited by
Baxter, J. B., & Guglietta, G. W. (2011) · Analytical Chemistry · doi:10.1021/ac200907z · Cited by 477
Rapid-scanning terahertz precision spectrometer with more than 6 THz spectral coverage
Klatt, G., Gebs, R., Janke, C., Dekorsy, T., & Bartels, A. (2009) · Optics Express · doi:10.1364/oe.17.022847 · Cited by 95
Emission of terahertz pulses from nanostructured metal surfaces
Ramanandan, G. K. P., Ramakrishnan, G., Kumar, N., Adam, A. J. L., & Planken, P. C. M. (2014) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/47/37/374003 · Cited by 51
“…Grischkowsky 1990, Zhao et al 2002), optical rectification in non-linear optical crystals, (Zhang et al 1992, Nahata et al 1996, Hebling et al 2008, Chakkittakandy et al 2008), the photo-Dember effect at semiconductor surfaces (Kono et al 2000, Gu et al 2002, Johnston et al 2002), and generation…”
BackgroundSelf-citation
Metadata
- Authors
- Chakkittakandy, R., Corver, J. A., & Planken, P. C.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2008-08-07
- Volume
- 16
- Issue
- 17
- Pages
- 12794
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2074922060
- Cited by
- 39
- References
- 6
- FWCI
- 3.88
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.