The DOI matches its Crossref record.
Doppler optical micro-angiography for volumetric imaging of vascular perfusion in vivo
Open accessAbstract
We propose a Doppler optical micro-angiography (DOMAG) method to image flow velocities of the blood flowing in functional vessels within microcirculatory tissue beds in vivo. The method takes the advantages of recently developed optical micro-angiography (OMAG) technology, in which the endogenous optical signals backscattered from the moving blood cells are isolated from those originated from the tissue background, i.e., the tissue microstructures. The phase difference between adjacent A scans of OMAG flow signals is used to evaluate the flow velocity, similar to phase-resolved Doppler optical coherence tomography (PRDOCT). To meet the requirement of correlation between adjacent A scans in using the phase resolved technique to evaluate flow velocity, an ideal tissue-sample background (i.e., optically homogeneous tissue sample) is digitally reconstructed to replace the signals that represent the heterogeneous features of the static sample that are rejected in the OMAG flow images. Because of the ideal optical-homogeneous sample, DOMAG is free from the characteristic texture pattern noise due to the heterogeneous property of sample, leading to dramatic improvement of the imaging performance. A series of phantom flow experiments are performed to evaluate quantitatively the improved imaging performance. We then conduct in vivo experiments on a mouse brain to demonstrate that DOMAG is capable of quantifying the flow velocities within cerebrovascular network, down to capillary level resolution. Finally, we compare the in vivo imaging performance of DOMAG with that of PRDOCT, and show that DOMAG delivers at least 15-fold increase over the PRDOCT method in terms of the lower limit of flow velocity that can be detected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Split-spectrum amplitude-decorrelation angiography with optical coherence tomography
Jia, Y., Tan, O., Tokayer, J., Potsaid, B., Wang, Y., Liu, J. J., Kraus, M. F., Subhash, H., Fujimoto, J. G., Hornegger, J., et al. (2012) · Optics Express · doi:10.1364/oe.20.004710 · Cited by 1,841
Yao, J., & Wang, L. V. (2013) · Laser & Photonics Reviews · doi:10.1002/lpor.201200060 · Cited by 616
Park, D.-W., Schendel, A. A., Mikael, S., Brodnick, S. K., Richner, T. J., Ness, J. P., Hayat, M. R., Atry, F., Frye, S. T., Pashaie, R., et al. (2014) · Nature Communications · doi:10.1038/ncomms6258 · Cited by 565
Optical coherence tomography based angiography [Invited]
Chen, C.-L., & Wang, R. K. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001056 · Cited by 415
Self-citationMethods and algorithms for optical coherence tomography-based angiography: a review and comparison
Zhang, A., Zhang, Q., Chen, C.-L., & Wang, R. K. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.10.100901 · Cited by 371
Self-citation
Metadata
- Authors
- Wang, R. K., & An, L.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2009-05-13
- Volume
- 17
- Issue
- 11
- Pages
- 8926
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2102838953
- Cited by
- 220
- References
- 0
- FWCI
- 12.03
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Doppler optical micro-angiography for volumetric imaging of vascular perfusion in vivo. https://app.cochat.ai/papers/10.1364/oe.17.008926
- The paper
- Wang, R. K., & An, L. (2009). Doppler optical micro-angiography for volumetric imaging of vascular perfusion in vivo. Optics Express. https://doi.org/10.1364/oe.17.008926
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.