The DOI matches its Crossref record.
Phase tomography from x-ray coherent diffractive imaging projections
Open accessAbstract
Coherent diffractive imaging provides accurate phase projections that can be tomographically combined to yield detailed quantitative 3D reconstructions with a resolution that is not limited by imaging optics. We present robust algorithms for post-processing and alignment of these tomographic phase projections. A simple method to remove undesired constant and linear phase terms on the reconstructions is given. Also, we provide an algorithm for automatic alignment of projections that has good performance even for samples with no fiducial markers. Currently applied to phase projections, this alignment algorithm has proven to be robust and should also be useful for lens-based tomography techniques that pursue nanoscale 3D imaging. Lastly, we provide a method for tomographic reconstruction that works on phase projections that are known modulo 2π, such that the phase unwrapping step is avoided. We demonstrate the performance of these algorithms by 3D imaging of bacteria population in legume root-nodule cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
High-resolution non-destructive three-dimensional imaging of integrated circuits
Holler, M., Guizar-Sicairos, M., Tsai, E. H. R., Dinapoli, R., Müller, E., Bunk, O., Raabe, J., & Aeppli, G. (2017) · Nature · doi:10.1038/nature21698 · Cited by 497
Self-citationX-ray ptychographic computed tomography at 16 nm isotropic 3D resolution
Holler, M., Diaz, A., Guizar-Sicairos, M., Karvinen, P., Färm, E., Härkönen, E., Ritala, M., Menzel, A., Raabe, J., & Bunk, O. (2014) · Scientific Reports · doi:10.1038/srep03857 · Cited by 357
Self-citationCuesta, A., De la Torre, A. G., Santacruz, I., Trtik, P., da Silva, J. C., Diaz, A., Holler, M., & Aranda, M. A. G. (2017) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.6b10048 · Cited by 55
Self-citationCritical appraisal of tubular putative eumetazoans from the Ediacaran Weng'an Doushantuo biota
Cunningham, J. A., Vargas, K., Pengju, L., Belivanova, V., Marone, F., Martínez-Pérez, C., Guizar-Sicairos, M., Holler, M., Bengtson, S., & Donoghue, P. C. J. (2015) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2015.1169 · Cited by 26
Self-citationProbing Organic Thin Films by Coherent X-ray Imaging and X-ray Scattering
Patil, N., Narayanan, T., Michels, L., Skjønsfjell, E. T. B., Guizar-Sicairos, M., Van den Brande, N., Claessens, R., Van Mele, B., & Breiby, D. W. (2019) · ACS Applied Polymer Materials · doi:10.1021/acsapm.9b00324 · Cited by 6
Self-citation
Metadata
- Authors
- Guizar-Sicairos, M., Diaz, A., Holler, M., Lucas, M. S., Menzel, A., Wepf, R. A., & Bunk, O.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2011-10-12
- Volume
- 19
- Issue
- 22
- Pages
- 21345
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2116749344
- Cited by
- 221
- References
- 0
- FWCI
- 8.08
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Phase tomography from x-ray coherent diffractive imaging projections. https://app.cochat.ai/papers/10.1364/oe.19.021345
- The paper
- Guizar-Sicairos, M., Diaz, A., Holler, M., Lucas, M. S., Menzel, A., Wepf, R. A., & Bunk, O. (2011). Phase tomography from x-ray coherent diffractive imaging projections. Optics Express. https://doi.org/10.1364/oe.19.021345
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.