The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
X-ray ptychographic computed tomography at 16 nm isotropic 3D resolution
Open accessAbstract
X-ray ptychography is a scanning variant of coherent diffractive imaging with the ability to image large fields of view at high resolution. It further allows imaging of non-isolated specimens and can produce quantitative mapping of the electron density distribution in 3D when combined with computed tomography. The method does not require imaging lenses, which makes it dose efficient and suitable to multi-keV X-rays, where efficient photon counting, pixelated detectors are available. Here we present the first highly resolved quantitative X-ray ptychographic tomography of an extended object yielding 16 nm isotropic 3D resolution recorded at 2 Å wavelength. This first-of-its-kind demonstration paves the way for ptychographic X-ray tomography to become a promising method for X-ray imaging of representative sample volumes at unmatched resolution, opening tremendous potential for characterizing samples in materials science and biology by filling the resolution gap between electron microscopy and other X-ray imaging techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phase retrieval algorithms: a comparison
Fienup, J. R. (1982) · Applied Optics · doi:10.1364/ao.21.002758 · Cited by 5,596
Miao, J., Charalambous, P., Kirz, J., & Sayre, D. (1999) · Nature · doi:10.1038/22498 · Cited by 1,976
Efficient subpixel image registration algorithms
Guizar-Sicairos, M., Thurman, S. T., & Fienup, J. R. (2008) · Optics Letters · doi:10.1364/ol.33.000156 · Cited by 1,905
Self-citationHigh-Resolution Scanning X-ray Diffraction Microscopy
Thibault, P., Dierolf, M., Menzel, A., Bunk, O., David, C., & Pfeiffer, F. (2008) · Science · doi:10.1126/science.1158573 · Cited by 1,321
Self-citationFourier shell correlation threshold criteria
van Heel, M., & Schatz, M. (2005) · Journal of Structural Biology · doi:10.1016/j.jsb.2005.05.009 · Cited by 927
Ptychographic X-ray computed tomography at the nanoscale
Dierolf, M., Menzel, A., Thibault, P., Schneider, P., Kewish, C. M., Wepf, R., Bunk, O., & Pfeiffer, F. (2010) · Nature · doi:10.1038/nature09419 · Cited by 926
Self-citationConformal Coating on Ultrahigh-Aspect-Ratio Nanopores of Anodic Alumina by Atomic Layer Deposition
Elam, J. W., Routkevitch, D., Mardilovich, P. P., & George, S. M. (2003) · Chemistry of Materials · doi:10.1021/cm0303080 · Cited by 623
High-resolution ab initio three-dimensional x-ray diffraction microscopy
Chapman, H. N., Barty, A., Marchesini, S., Noy, A., Hau-Riege, S. P., Cui, C., Howells, M. R., Rosen, R., He, H., Spence, J. C. H., et al. (2006) · Journal of the Optical Society of America A · doi:10.1364/josaa.23.001179 · Cited by 592
Phase retrieval with transverse translation diversity: a nonlinear optimization approach
Guizar-Sicairos, M., & Fienup, J. R. (2008) · Optics Express · doi:10.1364/oe.16.007264 · Cited by 525
Self-citationAn assessment of the resolution limitation due to radiation-damage in X-ray diffraction microscopy
Howells, M. R., Beetz, T., Chapman, H. N., Cui, C., Holton, J. M., Jacobsen, C. J., Kirz, J., Lima, E., Marchesini, S., Miao, H., et al. (2009) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/j.elspec.2008.10.008 · Cited by 524
Cited by
Bultreys, T., De Boever, W., & Cnudde, V. (2016) · Earth-Science Reviews · doi:10.1016/j.earscirev.2016.02.001 · Cited by 474
Cuesta, A., De la Torre, A. G., Santacruz, I., Trtik, P., da Silva, J. C., Diaz, A., Holler, M., & Aranda, M. A. G. (2017) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.6b10048 · Cited by 55
Self-citationCritical appraisal of tubular putative eumetazoans from the Ediacaran Weng'an Doushantuo biota
Cunningham, J. A., Vargas, K., Pengju, L., Belivanova, V., Marone, F., Martínez-Pérez, C., Guizar-Sicairos, M., Holler, M., Bengtson, S., & Donoghue, P. C. J. (2015) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2015.1169 · Cited by 26
Self-citation
Metadata
- Authors
- Holler, M., Diaz, A., Guizar-Sicairos, M., Karvinen, P., Färm, E., Härkönen, E., Ritala, M., Menzel, A., Raabe, J., & Bunk, O.
- Venue
- Scientific Reports
- Published
- 2014-01-24
- Volume
- 4
- Issue
- 1
- Pages
- 3857-3857
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2142894245
- Cited by
- 357
- References
- 17
- FWCI
- 37.13
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: X-ray ptychographic computed tomography at 16 nm isotropic 3D resolution. https://app.cochat.ai/papers/10.1038/srep03857
- The paper
- Holler, M., Diaz, A., Guizar-Sicairos, M., Karvinen, P., Färm, E., Härkönen, E., Ritala, M., Menzel, A., Raabe, J., & Bunk, O. (2014). X-ray ptychographic computed tomography at 16 nm isotropic 3D resolution. Scientific Reports. https://doi.org/10.1038/srep03857
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.