CoChat

Non-contact detection of oxygen saturation based on visible light imaging device using ambient light

Open access
Kong, Lingqin, Zhao, Yuejin, Dong, Liquan, Jian, Yiyun, Jin, Xiaoli, Li, Bing, Feng, Yun, Liu, Ming, Liu, Xiaohua, Wu, Hong · 2013 · Optics Express
Cited by 187

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

A method that remotely measures blood oxygen saturation through two cameras under regular lighting is proposed and experimentally demonstrated. Two narrow-band filters with their visible wavelength of 660nm and 520nm are mounted to two cameras respectively, which are then used to capture two photoplethysmographic (PPG) from the subject simultaneously. The data gathered from this system, including both blood oxygen saturation and heart rate, is compared to the output of a traditional figure blood volume pulse (BVP) senor that was employed on the subject at the same time. Result of the comparison showed that the data from the new, non-contact system is consistent and comparable with the BVP senor. Compared to other camera-based measuring method, which requires additional close-up lighting, this new method is achievable under regular lighting condition, therefore more stable and easier to implement. This is the first demonstration of an accurate video-based method for non-contact oxygen saturation measurements by using ambient light with their respective visible wavelength of 660nm and 520nm which is free from interference of the light in other bands.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/oe.21.017464

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 187

Metadata

Authors
Kong, L., Zhao, Y., Dong, L., Jian, Y., Jin, X., Li, B., Feng, Y., Liu, M., Liu, X., & Wu, H.
Venue
Optics Express
Published
2013-07-15
Volume
21
Issue
15
Pages
17464
ISSN
1094-4087 (ISSN-L)
OpenAlex
W2024811422
Cited by
187
References
4
FWCI
5.85
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Non-contact detection of oxygen saturation based on visible light imaging device using ambient light. https://app.cochat.ai/papers/10.1364/oe.21.017464
The paper
Kong, L., Zhao, Y., Dong, L., Jian, Y., Jin, X., Li, B., Feng, Y., Liu, M., Liu, X., & Wu, H. (2013). Non-contact detection of oxygen saturation based on visible light imaging device using ambient light. Optics Express. https://doi.org/10.1364/oe.21.017464

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.