The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Kilometer-range depth imaging at 1550 nm wavelength using an InGaAs/InP single-photon avalanche diode detector
Open accessAbstract
We have used an InGaAs/InP single-photon avalanche diode detector module in conjunction with a time-of-flight depth imager operating at a wavelength of 1550 nm, to acquire centimeter resolution depth images of low signature objects at stand-off distances of up to one kilometer. The scenes of interest were scanned by the transceiver system using pulsed laser illumination with an average optical power of less than 600 µW and per-pixel acquisition times of between 0.5 ms and 20 ms. The fiber-pigtailed InGaAs/InP detector was Peltier-cooled and operated at a temperature of 230 K. This detector was used in electrically gated mode with a single-photon detection efficiency of about 26% at a dark count rate of 16 kilocounts per second. The system's overall instrumental temporal response was 144 ps full width at half maximum. Measurements made in daylight on a number of target types at ranges of 325 m, 910 m, and 4.5 km are presented, along with an analysis of the depth resolution achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The HITRAN2016 molecular spectroscopic database
Gordon, I. E., Rothman, L. S., Hill, C., Kochanov, R. V., Tan, Y., Bernath, P. F., Birk, M., Boudon, V., Campargue, A., Chance, K. V., et al. (2017) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2017.06.038 · Cited by 7,721
Performance and design of InGaAs/InP photodiodes for single-photon counting at 155 µm
Hiskett, P. A., Buller, G. S., Loudon, A. Y., Smith, J. M., Gontijo, I., Walker, A. C., Townsend, P. D., & Robertson, M. J. (2000) · Applied Optics · doi:10.1364/ao.39.006818 · Cited by 126
Self-citationRarity, J. G., Wall, T. E., Ridley, K. D., Owens, P. C. M., & Tapster, P. R. (2000) · Applied Optics · doi:10.1364/ao.39.006746 · Cited by 95
Cited by
Kirmani, A., Venkatraman, D., Shin, D., Colaço, A., Wong, F. N. C., Shapiro, J. H., & Goyal, V. K. (2014) · Science · doi:10.1126/science.1246775 · Cited by 473
Single-photon three-dimensional imaging at up to 10 kilometers range
Pawlikowska, A. M., Halimi, A., Lamb, R. A., & Buller, G. S. (2017) · Optics Express · doi:10.1364/oe.25.011919 · Cited by 376
Self-citationHigh performance planar germanium-on-silicon single-photon avalanche diode detectors
Vines, P., Kuzmenko, K., Kirdoda, J., Dumas, D. C. S., Mirza, M. M., Millar, R. W., Paul, D. J., & Buller, G. S. (2019) · Nature Communications · doi:10.1038/s41467-019-08830-w · Cited by 195
Self-citation
Metadata
- Authors
- McCarthy, A., Ren, X., Della Frera, A., Gemmell, N. R., Krichel, N. J., Scarcella, C., Ruggeri, A., Tosi, A., & Buller, G. S.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2013-09-12
- Volume
- 21
- Issue
- 19
- Pages
- 22098
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2049372390
- Cited by
- 225
- References
- 3
- FWCI
- 15.41
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Kilometer-range depth imaging at 1550 nm wavelength using an InGaAs/InP single-photon avalanche diode detector. https://app.cochat.ai/papers/10.1364/oe.21.022098
- The paper
- McCarthy, A., Ren, X., Della Frera, A., Gemmell, N. R., Krichel, N. J., Scarcella, C., Ruggeri, A., Tosi, A., & Buller, G. S. (2013). Kilometer-range depth imaging at 1550 nm wavelength using an InGaAs/InP single-photon avalanche diode detector. Optics Express. https://doi.org/10.1364/oe.21.022098
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.