Noise reduction and signal-to-noise ratio improvement of atomic magnetometers with optical gradiometer configurations
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
In the field of biomagnetic measurement, optically-pumped atomic magnetometers (OPAMs) have attracted significant attention. With the improvement of signal response and the reduction of sensor noise, the sensitivity of OPAMs is limited mainly by environmental magnetic noise. To reduce this magnetic noise, we developed the optical gradiometer, in which the differential output of two distinct measurement areas inside a glass cell was obtained directly via the magneto-optical rotation of one probe beam. When operating in appropriate conditions, the sensitivity was improved by the differential measurement of the optical gradiometer. In addition, measurements of the pseudo-magnetic noise and signal showed the improvement of the signal-to-noise ratio. These results demonstrate the feasibility of our optical gradiometer as an efficient method for reducing the magnetic noise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
A compact, high performance atomic magnetometer for biomedical applications
Shah, V. K., & Wakai, R. T. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/8153 · Cited by 322
Dynamical mapping of the human cardiomagnetic field with a room-temperature, laser-optical sensor
Bison, G., Wynands, R., & Weis, A. (2003) · Optics Express · doi:10.1364/oe.11.000904 · Cited by 100
Cited by
Characterizing atomic magnetic gradiometers for fetal magnetocardiography
Sulai, I. A., DeLand, Z. J., Bulatowicz, M. D., Wahl, C. P., Wakai, R. T., & Walker, T. G. (2019) · Review of Scientific Instruments · doi:10.1063/1.5091007 · Cited by 79
Zhang, R., Mhaskar, R., Smith, K., & Prouty, M. (2020) · Applied Physics Letters · doi:10.1063/5.0004746 · Cited by 48
“A similar optical read-out scheme was explored in the SERF regime [18].”
MethodOptimal magnetic sensor vests for cardiac source imaging
Lau, S., Petković, B., & Haueisen, J. (2016) · Sensors · doi:10.3390/s16060754 · Cited by 17
“Current developments aim at increasing the dynamic range, developing vectorial OPMs [36], and integrating the OPM technology into multi-channel systems [27].”
Background
Metadata
- Authors
- Kamada, K., Ito, Y., Ichihara, S., Mizutani, N., & Kobayashi, T.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2015-03-06
- Volume
- 23
- Issue
- 5
- Pages
- 6976
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2010276661
- Cited by
- 43
- References
- 4
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noise reduction and signal-to-noise ratio improvement of atomic magnetometers with optical gradiometer configurations. https://app.cochat.ai/papers/10.1364/oe.23.006976
- The paper
- Kamada, K., Ito, Y., Ichihara, S., Mizutani, N., & Kobayashi, T. (2015). Noise reduction and signal-to-noise ratio improvement of atomic magnetometers with optical gradiometer configurations. Optics Express. https://doi.org/10.1364/oe.23.006976
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.