The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
Feedback-based wavefront shaping
Open accessAbstract
Light scattering was thought to be the fundamental limitation for the depth at which optical imaging methods can retain their resolution and sensitivity. However, it was shown that light can be focused inside even the most strongly scattering objects by spatially shaping the wavefront of the incident light. This review summarizes recently developed feedback-based approaches for focusing light inside and through scattering objects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Deep tissue two-photon microscopy
Helmchen, F., & Denk, W. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,153
Random-matrix theory of quantum transport
Beenakker, C. W. J. (1997) · Reviews of Modern Physics · doi:10.1103/revmodphys.69.731 · Cited by 2,551
Pappu, R., Recht, B., Taylor, J., & Gershenfeld, N. (2002) · Science · doi:10.1126/science.1074376 · Cited by 2,018
Focusing coherent light through opaque strongly scattering media
Vellekoop, I. M., & Mosk, A. P. (2007) · Optics Letters · doi:10.1364/ol.32.002309 · Cited by 1,919
Self-citationGoing deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Popoff, S. M., Lerosey, G., Carminati, R., Fink, M., Boccara, A. C., & Gigan, S. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.100601 · Cited by 1,854
Reconstruction of Zebrafish Early Embryonic Development by Scanned Light Sheet Microscopy
Keller, P. J., Schmidt, A. D., Wittbrodt, J., & Stelzer, E. H. K. (2008) · Science · doi:10.1126/science.1162493 · Cited by 1,560
Looking and listening to light: the evolution of whole-body photonic imaging
Ntziachristos, V., Ripoll, J., Wang, L. V., & Weissleder, R. (2005) · Nature Biotechnology · doi:10.1038/nbt1074 · Cited by 1,557
Controlling waves in space and time for imaging and focusing in complex media
Mosk, A. P., Lagendijk, A., Lerosey, G., & Fink, M. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.88 · Cited by 1,536
Cited by
Light fields in complex media: Mesoscopic scattering meets wave control
Rotter, S., & Gigan, S. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.015005 · Cited by 654
Adaptive optical fluorescence microscopy
Ji, N. (2017) · Nature Methods · doi:10.1038/nmeth.4218 · Cited by 527
Medical Imaging of Microrobots: Toward In Vivo Applications
Aziz, A., Pane, S., Iacovacci, V., Koukourakis, N., Czarske, J., Menciassi, A., Medina-Sánchez, M., & Schmidt, O. G. (2020) · ACS Nano · doi:10.1021/acsnano.0c05530 · Cited by 287
Tzang, O., & Piestun, R. (2016) · Optics Express · doi:10.1364/oe.24.028122 · Cited by 32
Metadata
- Authors
- Vellekoop, I. M.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2015-04-30
- Volume
- 23
- Issue
- 9
- Pages
- 12189
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2008913411
- Cited by
- 427
- References
- 64
- FWCI
- 12.40
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Feedback-based wavefront shaping. https://app.cochat.ai/papers/10.1364/oe.23.012189
- The paper
- Vellekoop, I. M. (2015). Feedback-based wavefront shaping. Optics Express. https://doi.org/10.1364/oe.23.012189
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.