The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Medical Imaging of Microrobots: Toward In Vivo Applications
Open accessAbstract
Medical microrobots (MRs) have been demonstrated for a variety of non-invasive biomedical applications, such as tissue engineering, drug delivery, and assisted fertilization, among others. However, most of these demonstrations have been carried out in in vitro settings and under optical microscopy, being significantly different from the clinical practice. Thus, medical imaging techniques are required for localizing and tracking such tiny therapeutic machines when used in medical-relevant applications. This review aims at analyzing the state of the art of microrobots imaging by critically discussing the potentialities and limitations of the techniques employed in this field. Moreover, the physics and the working principle behind each analyzed imaging strategy, the spatiotemporal resolution, and the penetration depth are thoroughly discussed. The paper deals with the suitability of each imaging technique for tracking single or swarms of MRs and discusses the scenarios where contrast or imaging agent’s inclusion is required, either to absorb, emit, or reflect a determined physical signal detected by an external system. Finally, the review highlights the existing challenges and perspective solutions which could be promising for future in vivo applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Controlling waves in space and time for imaging and focusing in complex media
Mosk, A. P., Lagendijk, A., Lerosey, G., & Fink, M. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.88 · Cited by 1,536
Reconfigurable magnetic microrobot swarm: Multimode transformation, locomotion, and manipulation
Xie, H., Sun, M., Fan, X., Lin, Z., Chen, W., Wang, L., Dong, L., & He, Q. (2019) · Science Robotics · doi:10.1126/scirobotics.aav8006 · Cited by 772
Wagener, P., Jakobi, J., Rehbock, C., Chakravadhanula, V. S. K., Thede, C., Wiedwald, U., Bartsch, M., Kienle, L., & Barcikowski, S. (2016) · Scientific Reports · doi:10.1038/srep23352 · Cited by 150
Cited by
Magnetically Driven Micro and Nanorobots
Zhou, H., Mayorga-Martinez, C. C., Pané, S., Zhang, L., & Pumera, M. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01234 · Cited by 889
Engineering microrobots for targeted cancer therapies from a medical perspective
Schmidt, C. K., Medina-Sánchez, M., Edmondson, R. J., & Schmidt, O. G. (2020) · Nature Communications · doi:10.1038/s41467-020-19322-7 · Cited by 441
Self-citationWang, Q., Chan, K. F., Schweizer, K., Du, X., Jin, D., Yu, S. C. H., Nelson, B. J., & Zhang, L. (2021) · Science Advances · doi:10.1126/sciadv.abe5914 · Cited by 348
Artificial Intelligence in Medical Sensors for Clinical Decisions
Haick, H., & Tang, N. (2021) · ACS Nano · doi:10.1021/acsnano.1c00085 · Cited by 231
Metadata
- Authors
- Aziz, A., Pane, S., Iacovacci, V., Koukourakis, N., Czarske, J., Menciassi, A., Medina-Sánchez, M., & Schmidt, O. G.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-09-01
- Volume
- 14
- Issue
- 9
- Pages
- 10865-10893
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W3081573251
- Cited by
- 287
- References
- 5
- FWCI
- 32.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Medical Imaging of Microrobots: Toward In Vivo Applications. https://app.cochat.ai/papers/10.1021/acsnano.0c05530
- The paper
- Aziz, A., Pane, S., Iacovacci, V., Koukourakis, N., Czarske, J., Menciassi, A., Medina-Sánchez, M., & Schmidt, O. G. (2020). Medical Imaging of Microrobots: Toward In Vivo Applications. ACS Nano. https://doi.org/10.1021/acsnano.0c05530
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.