The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Single-photon three-dimensional imaging at up to 10 kilometers range
Open accessAbstract
Depth and intensity profiling of targets at a range of up to 10 km is demonstrated using time-of-flight time-correlated single-photon counting technique. The system comprised a pulsed laser source at 1550 nm wavelength, a monostatic scanning transceiver and a single-element InGaAs/InP single-photon avalanche diode (SPAD) detector. High-resolution three-dimensional images of various targets acquired over ranges between 800 metres and 10.5 km demonstrate long-range depth and intensity profiling, feature extraction and the potential for target recognition. Using a total variation restoration optimization algorithm, the acquisition time necessary for each pixel could be reduced by at least a factor of ten compared to a pixel-wise image processing approach. Kilometer range depth profiles are reconstructed with average signal returns of less than one photon per pixel.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, I. I., McArthur, B., & Korevaar, E. J. (2001) · SPIE Proceedings · doi:10.1117/12.417512 · Cited by 910
Photon-efficient imaging with a single-photon camera
Shin, D., Xu, F., Venkatraman, D., Lussana, R., Villa, F., Zappa, F., Goyal, V. K., Wong, F. N. C., & Shapiro, J. H. (2016) · Nature Communications · doi:10.1038/ncomms12046 · Cited by 325
Single-photon generation and detection
Buller, G. S., & Collins, R. J. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/1/012002 · Cited by 268
Self-citationMcCarthy, A., Ren, X., Della Frera, A., Gemmell, N. R., Krichel, N. J., Scarcella, C., Ruggeri, A., Tosi, A., & Buller, G. S. (2013) · Optics Express · doi:10.1364/oe.21.022098 · Cited by 225
Self-citationLaser-based distance measurement using picosecond resolution time-correlated single-photon counting
Pellegrini, S., Buller, G. S., Smith, J. M., Wallace, A. M., & Cova, S. (2000) · Measurement Science and Technology · doi:10.1088/0957-0233/11/6/314 · Cited by 200
Self-citationBuller, G., & Wallace, A. (2007) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2007.902850 · Cited by 189
Self-citationBayesian Analysis of Lidar Signals with Multiple Returns
Hernandez-Marin, S., Wallace, A. M., & Gibson, G. J. (2007) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2007.1122 · Cited by 145
Lidar waveform based analysis of depth images constructed using sparse single-photon dataPreprint
Altmann, Y., Ren, X., McCarthy, A., Buller, G. S., & McLaughlin, S. (2015) · arXiv (Cornell University) · doi:10.1109/tip.2016.2526784 · Cited by 139
Self-citationResolving range ambiguity in a photon counting depth imager operating at kilometer distances
Krichel, N. J., McCarthy, A., & Buller, G. S. (2010) · Optics Express · doi:10.1364/oe.18.009192 · Cited by 121
Self-citationLaser ranging at 1550 nm with 1-GHz sine-wave gated InGaAs/InP APD single-photon detector
Ren, M., Gu, X., Liang, Y., Kong, W., Wu, E., Wu, G., & Zeng, H. (2011) · Optics Express · doi:10.1364/oe.19.013497 · Cited by 107
Cited by
High performance planar germanium-on-silicon single-photon avalanche diode detectors
Vines, P., Kuzmenko, K., Kirdoda, J., Dumas, D. C. S., Mirza, M. M., Millar, R. W., Paul, D. J., & Buller, G. S. (2019) · Nature Communications · doi:10.1038/s41467-019-08830-w · Cited by 195
Self-citation
Metadata
- Authors
- Pawlikowska, A. M., Halimi, A., Lamb, R. A., & Buller, G. S.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2017-05-12
- Volume
- 25
- Issue
- 10
- Pages
- 11919
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2613985060
- Cited by
- 376
- References
- 13
- FWCI
- 32.88
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.