The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography
Open accessAbstract
Using a low-coherence Michelson interferometer, we measure two-dimensional images of optical birefringence in bovine tendon as a function of depth. Polarization-sensitive detection of the signal formed by interference of backscattered light from the sample and a mirror in the reference arm give the optical phase delay between light that is propagating along the fast and slow axes of the birefringent tendon. Images showing the change in birefringence in response to laser irradiation are presented. The technique permits rapid noncontact investigation of tissue structural properties through two-dimensional imaging of birefringence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Spectroscopy and Imaging with Diffusing Light
Yodh, A., & Chance, B. (1995) · Physics Today · doi:10.1063/1.881445 · Cited by 800
PATHOLOGIC ANALYSIS OF PHOTOTHERMAL AND PHOTOMECHANICAL EFFECTS OF LASER–TISSUE INTERACTIONS
Thomsen, S. (1991) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1991.tb09897.x · Cited by 585
Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging
Hee, M. R., Swanson, E. A., Fujimoto, J. G., & Huang, D. (1992) · Journal of the Optical Society of America B · doi:10.1364/josab.9.000903 · Cited by 582
Tearney, G. J., Brezinski, M. E., Bouma, B. E., Hee, M. R., Southern, J. F., & Fujimoto, J. G. (1995) · Optics Letters · doi:10.1364/ol.20.002258 · Cited by 562
Fercher, A. F. (1996) · Journal of Biomedical Optics · doi:10.1117/12.231361 · Cited by 534
Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media
Chen, Z., Milner, T. E., Dave, D., & Nelson, J. S. (1997) · Optics Letters · doi:10.1364/ol.22.000064 · Cited by 443
Self-citationContinuous-wave ultrasonic modulation of scattered laser light to image objects in turbid media
Wang, L., Jacques, S. L., & Zhao, X. (1995) · Optics Letters · doi:10.1364/ol.20.000629 · Cited by 241
Ultrastructures of rabbit corneal stroma: Mapping of optical and morphological anisotropies
Chang, E. P., & Chien, J. C. W. (1974) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(74)90280-3 · Cited by 22
Cited by
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Quantitative phase imaging in biomedicine
Park, Y., Depeursinge, C., & Popescu, G. (2018) · Nature Photonics · doi:10.1038/s41566-018-0253-x · Cited by 1,802
Optical coherence tomography for ultrahigh resolution in vivo imaging
Fujimoto, J. G. (2003) · Nature Biotechnology · doi:10.1038/nbt892 · Cited by 1,033
State-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906
Theory, developments and applications of optical coherence tomography
Tomlins, P. H., & Wang, R. K. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/002 · Cited by 631
Metadata
- Authors
- de Boer, J. F., Milner, T. E., van Gemert, M. J. C., & Nelson, J. S.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1997-06-15
- Volume
- 22
- Issue
- 12
- Pages
- 934
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2164607765
- Cited by
- 883
- References
- 9
- FWCI
- 18.51
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.