Two-photon near- and far-field fluorescence microscopy with continuous-wave excitation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We report on scanning far- and near-field two-photon microscopy of cell nuclei stained with DAPI and bisbenzimidazole Hoechst 33342 (BBI-342) with the 647-nm laser line of a cw ArKr mixed-gas laser. Two-photon-excited fluorescence images are obtained for 50-200 mW of average power at the sample. A nearly quadratic dependence of fluorescence intensity on laser power confirmed the two-photon effect. The nonlinearity was further supported by evidence of three-dimensional sectioning in a scanning far-field microscope. We find that the cw two-photon irradiation sufficient for imaging within typically 5 s does not significantly impair cell cycling of BBI-342-labeled live cells. Finally, high-resolution imaging in scanning near-field microscopy with good contrast is demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xu, C., & Webb, W. W. (1996) · Journal of the Optical Society of America B · doi:10.1364/josab.13.000481 · Cited by 2,198
Cited by
Multiphoton Absorbing Materials: Molecular Designs, Characterizations, and Applications
He, G. S., Tan, L.-S., Zheng, Q., & Prasad, P. N. (2008) · Chemical Reviews · doi:10.1021/cr050054x · Cited by 2,156
Three-Dimensional Optical Data Storage Using Photochromic Materials
Kawata, S., & Kawata, Y. (2000) · Chemical Reviews · doi:10.1021/cr980073p · Cited by 1,479
Multiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265
“This is consistent with the observations that despite high light intensities in the optical trap, the temperature increase is less than 2 K, thus excluding thermal toxic effects (Liu et al., 1995; SchoÈnle & Hell et al., 1998).”
BackgroundResultTwo-Photon Excitation Fluorescence Microscopy
So, P. T. C., Dong, C. Y., Masters, B. R., & Berland, K. M. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.399 · Cited by 1,057
Highly Nonlinear Photodamage in Two-Photon Fluorescence Microscopy
Hopt, A., & Neher, E. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76173-5 · Cited by 442
“Further, König et al. (1996a) needed more power to achieve the same decreases in cloning efficiencies if they increased the laser wavelength. This result is consistent with our Eq. 14. With smaller structures, like axonal varicosities, we typically can use somewhat higher powers up to about 10 mW without causing serio…”
BackgroundInfluentialNonresonant Confocal Raman Imaging of DNA and Protein Distribution in Apoptotic Cells
Uzunbajakava, N., Lenferink, A., Kraan, Y., Volokhina, E., Vrensen, G., Greve, J., & Otto, C. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)75124-8 · Cited by 347
Two-photon fluorescence excitation and related techniques in biological microscopy
Diaspro, A., Chirico, G., & Collini, M. (2005) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583505004129 · Cited by 318
Ca2+ Fluorescence Imaging with Pico- and Femtosecond Two-Photon Excitation: Signal and Photodamage
Koester, H. J., Baur, D., Uhl, R., & Hell, S. W. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77063-3 · Cited by 264
Self-citationKönig, K., Becker, T. W., Fischer, P., Riemann, I., & Halbhuber, K.-J. (1999) · Optics Letters · doi:10.1364/ol.24.000113 · Cited by 259
Two-photon excitation STED microscopy
Moneron, G., & Hell, S. W. (2009) · Optics Express · doi:10.1364/oe.17.014567 · Cited by 238
Self-citation
Metadata
- Authors
- Hell, S. W., Booth, M., Wilms, S., Schnetter, C. M., Kirsch, A. K., Arndt-Jovin, D. J., & Jovin, T. M.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1998-08-01
- Volume
- 23
- Issue
- 15
- Pages
- 1238
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2062323346
- Cited by
- 83
- References
- 1
- FWCI
- 5.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.