The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Spectroscopic polarimetry with a channeled spectrum
Abstract
We describe a novel method for the spectroscopic measurement of the state of polarization (SOP) of light. A pair of thick birefringent retarders is incorporated into the spectroscopic polarimeter, so the generated channeled spectrum is composed of three quasi-cosinusoidal components carrying the information about the SOP of the light that is being measured. Fourier inversion of the channeled spectrum provides significant parameters for determination of the spectrally resolved Stokes parameters of light. No mechanically movable components for polarization control or active devices for polarization modulation are used, and all the Stokes parameters can be determined at once from only the single spectrum. The effectiveness of this method is demonstrated by the generation of elliptically polarized light whose SOP varies with wave number.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fourier-transform method of fringe-pattern analysis for computer-based topography and interferometry
Takeda, M., Ina, H., & Kobayashi, S. (1982) · Journal of the Optical Society of America · doi:10.1364/josa.72.000156 · Cited by 4,277
Automatic rotating element ellipsometers: Calibration, operation, and real-time applications
Collins, R. W. (1990) · Review of Scientific Instruments · doi:10.1063/1.1141417 · Cited by 282
Optical constants for silicon at 300 and 10 K determined from 1.64 to 4.73 eV by ellipsometry
Jellison, G. E., & Modine, F. A. (1982) · Journal of Applied Physics · doi:10.1063/1.331113 · Cited by 182
General analysis and optimization of the four-detector photopolarimeter
Azzam, R. M. A., Elminyawi, I. M., & El-Saba, A. M. (1988) · Journal of the Optical Society of America A · doi:10.1364/josaa.5.000681 · Cited by 161
Four-channel polarimeter for time-resolved ellipsometry
Jellison, G. E. (1987) · Optics Letters · doi:10.1364/ol.12.000766 · Cited by 34
Cited by
Review of passive imaging polarimetry for remote sensing applications
Tyo, J. S., Goldstein, D. L., Chenault, D. B., & Shaw, J. A. (2006) · Applied Optics · doi:10.1364/ao.45.005453 · Cited by 1,716
Mueller polarimetric imaging for surgical and diagnostic applications: a review
Qi, J., & Elson, D. S. (2017) · Journal of Biophotonics · doi:10.1002/jbio.201600152 · Cited by 268
Space-variant polarization manipulation
Hasman, E., Biener, G., Niv, A., & Kleiner, V. (2005) · Progress in Optics · doi:10.1016/s0079-6638(05)47004-3 · Cited by 107
Metadata
- Authors
- Oka, K., & Kato, T.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1999-11-01
- Volume
- 24
- Issue
- 21
- Pages
- 1475
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2170586499
- Cited by
- 343
- References
- 5
- FWCI
- 2.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spectroscopic polarimetry with a channeled spectrum. https://app.cochat.ai/papers/10.1364/ol.24.001475
- The paper
- Oka, K., & Kato, T. (1999). Spectroscopic polarimetry with a channeled spectrum. Optics Letters. https://doi.org/10.1364/ol.24.001475
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.