The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Shift of whispering-gallery modes in microspheres by protein adsorption
Abstract
Biosensors based on the shift of whispering-gallery modes in microspheres accompanying protein adsorption are described by use of a perturbation theory. For random spatial adsorption, theory predicts that the shift should be inversely proportional to microsphere radius R and proportional to protein surface density and excess polarizability. Measurements are found to be consistent with the theory, and the correspondence enables the average surface area occupied by a single protein to be estimated. These results are consistent with crystallographic data for bovine serum albumin. The theoretical shift for adsorption of a single protein is found to be extremely sensitive to the target region, with adsorption in the most sensitive region varying as 1/R(5/2). Specific parameters for single protein or virus particle detection are predicted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2020) · Electromagnetic Processes · doi:10.2307/j.ctv131bv37.5 · Cited by 21,966
Classical Electrodynamics (2nd edn)
Brereton, M. G. (1976) · Physics Bulletin · doi:10.1088/0031-9112/27/8/041 · Cited by 2,433
Protein detection by optical shift of a resonant microcavity
Vollmer, F., Braun, D., Libchaber, A., Khoshsima, M., Teraoka, I., & Arnold, S. (2002) · Applied Physics Letters · doi:10.1063/1.1482797 · Cited by 903
Self-citationThree-Dimensional Structure of Human Serum Albumin
Carter, D. C., He, X.-M., Munson, S. H., Twigg, P. D., Gernert, K. M., Broom, M. B., & Miller, T. Y. (1989) · Science · doi:10.1126/science.2727704 · Cited by 602
Wen, J., Arakawa, T., & Philo, J. S. (1996) · Analytical Biochemistry · doi:10.1006/abio.1996.0345 · Cited by 504
Lam, C. C., Leung, P. T., & Young, K. (1992) · Journal of the Optical Society of America B · doi:10.1364/josab.9.001585 · Cited by 412
Excitation of resonances of microspheres on an optical fiber
Serpengüzel, A., Griffel, G., & Arnold, S. (1995) · Optics Letters · doi:10.1364/ol.20.000654 · Cited by 265
Self-citation
Cited by
Sensitive optical biosensors for unlabeled targets: A review
Fan, X., White, I. M., Shopova, S. I., Zhu, H., Suter, J. D., & Sun, Y. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.05.022 · Cited by 2,187
Whispering-gallery-mode biosensing: label-free detection down to single molecules
Vollmer, F., & Arnold, S. (2008) · Nature Methods · doi:10.1038/nmeth.1221 · Cited by 1,660
Self-citationLabel-Free, Single-Molecule Detection with Optical Microcavities
Armani, A. M., Kulkarni, R. P., Fraser, S. E., Flagan, R. C., & Vahala, K. J. (2007) · Science · doi:10.1126/science.1145002 · Cited by 1,141
On the performance quantification of resonant refractive index sensors
White, I. M., & Fan, X. (2008) · Optics Express · doi:10.1364/oe.16.001020 · Cited by 1,105
Micro-combs: A novel generation of optical sources
Pasquazi, A., Peccianti, M., Razzari, L., Moss, D. J., Coen, S., Erkintalo, M., Chembo, Y. K., Hansson, T., Wabnitz, S., Del’Haye, P., et al. (2018) · Physics Reports · doi:10.1016/j.physrep.2017.08.004 · Cited by 1,074
Metadata
- Authors
- Arnold, S., Khoshsima, M., Teraoka, I., Holler, S., & Vollmer, F.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2003-02-15
- Volume
- 28
- Issue
- 4
- Pages
- 272
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2166250628
- Cited by
- 736
- References
- 7
- FWCI
- 22.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.