The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Heavy water detection using ultra-high-Q microcavities
Abstract
Ultra-high-Q optical microcavities (Q>10(7)) provide one method for distinguishing chemically similar species. Resonators immersed in H(2)O have lower quality factors than those immersed in D(2)O due to the difference in optical absorption. This difference can be used to create a D(2)O detector. This effect is most noticeable at 1,300 nm, where the Q(H(2)O) is 106 and the Q(D(2)O) is 107. By monitoring Q, concentrations of 0.0001% [1 part in 106 per volume] of D(2)O in H(2)O have been detected. This sensitivity represents an order of magnitude improvement over previous techniques. Reversible detection was also demonstrated by cyclic introduction and flushing of D(2)O.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Constants of Water in the 200-nm to 200-μm Wavelength Region
Hale, G. M., & Querry, M. R. (1973) · Applied Optics · doi:10.1364/ao.12.000555 · Cited by 4,468
Ultra-high-Q toroid microcavity on a chip
Armani, D. K., Kippenberg, T. J., Spillane, S. M., & Vahala, K. J. (2003) · Nature · doi:10.1038/nature01371 · Cited by 2,214
Self-citationSpillane, S. M., Kippenberg, T. J., Painter, O. J., & Vahala, K. J. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.043902 · Cited by 650
Self-citationSensitive disk resonator photonic biosensor
Boyd, R. W., & Heebner, J. E. (2001) · Applied Optics · doi:10.1364/ao.40.005742 · Cited by 399
Resonant-enhanced evanescent-wave fluorescence biosensing with cylindrical optical cavities
Blair, S., & Chen, Y. (2001) · Applied Optics · doi:10.1364/ao.40.000570 · Cited by 159
Ultra-high-Q microcavity operation in H2O and D2O
Armani, A. M., Armani, A. M., Min, B., Vahala, K. J., & Spillane, S. M. (2005) · Applied Physics Letters · doi:10.1063/1.2099529 · Cited by 91
Self-citationAnnyas, J., Bicanic, D. D., & Schouten, F. J. M. (1999) · Applied Spectroscopy · doi:10.1366/0003702991946550 · Cited by 9
Cited by
Sensitive optical biosensors for unlabeled targets: A review
Fan, X., White, I. M., Shopova, S. I., Zhu, H., Suter, J. D., & Sun, Y. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.05.022 · Cited by 2,187
On the performance quantification of resonant refractive index sensors
White, I. M., & Fan, X. (2008) · Optics Express · doi:10.1364/oe.16.001020 · Cited by 1,105
Integrated optofluidics: A new river of light
Monat, C., Domachuk, P., & Eggleton, B. J. (2007) · Nature Photonics · doi:10.1038/nphoton.2006.96 · Cited by 955
Single-molecule nucleic acid interactions monitored on a label-free microcavity biosensor platform
Baaske, M. D., Foreman, M. R., & Vollmer, F. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.180 · Cited by 559
Vollmer, F., & Yang, L. (2012) · nanoph · doi:10.1515/nanoph-2012-0021 · Cited by 546
Metadata
- Authors
- Armani, A. M., & Vahala, K. J.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2006-06-15
- Volume
- 31
- Issue
- 12
- Pages
- 1896
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2119325823
- Cited by
- 254
- References
- 7
- FWCI
- 18.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.