The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Phase-stabilized, 15 W frequency comb at 28–48 μm
Open accessAbstract
We present a high-power optical-parametric-oscillator (OPO) based frequency comb in the mid-IR wavelength region. The system employs periodically poled lithium niobate and is singly resonant for the signal. It is synchronously pumped by a 10 W femtosecond Yb:fiber laser centered at 1.07 microm. The idler (signal) wavelength can be continuously tuned from 2.8 to 4.8 microm (1.76 to 1.37 microm) with a simultaneous bandwidth as high as 0.3 microm and a maximum average idler output power of 1.50 W. We also demonstrate the performance of the stabilized comb by recording the heterodyne beat with a narrow-linewidth diode laser. This OPO is an ideal source for frequency comb spectroscopy in the mid-IR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coherent Multiheterodyne Spectroscopy Using Stabilized Optical Frequency Combs
Coddington, I., Swann, W., & Newbury, N. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.013902 · Cited by 821
Molecular fingerprinting with the resolved modes of a femtosecond laser frequency comb
Diddams, S. A., Hollberg, L., & Mbele, V. (2007) · Nature · doi:10.1038/nature05524 · Cited by 805
Time-domain mid-infrared frequency-comb spectrometer
Keilmann, F., Gohle, C., & Holzwarth, R. (2004) · Optics Letters · doi:10.1364/ol.29.001542 · Cited by 734
Broadband Cavity Ringdown Spectroscopy for Sensitive and Rapid Molecular Detection
Thorpe, M. J., Moll, K. D., Jones, R. J., Safdi, B., & Ye, J. (2006) · Science · doi:10.1126/science.1123921 · Cited by 511
Self-citationSpectrometry with frequency combs
Schiller, S. (2002) · Optics Letters · doi:10.1364/ol.27.000766 · Cited by 445
Cavity-enhanced optical frequency comb spectroscopy: application to human breath analysis
Thorpe, M. J., Balslev-Clausen, D., Kirchner, M. S., & Ye, J. (2008) · Optics Express · doi:10.1364/oe.16.002387 · Cited by 324
Self-citationUnited Time-Frequency Spectroscopy for Dynamics and Global Structure
Marian, A., Stowe, M. C., Lawall, J. R., Felinto, D., & Ye, J. (2004) · Science · doi:10.1126/science.1105660 · Cited by 294
Self-citationOptical frequency comb with submillihertz linewidth and more than 10 W average power
Schibli, T. R., Hartl, I., Yost, D. C., Martin, M. J., Marcinkevičius, A., Fermann, M. E., & Ye, J. (2008) · Nature Photonics · doi:10.1038/nphoton.2008.79 · Cited by 260
Self-citationErny, C., Moutzouris, K., Biegert, J., Kühlke, D., Adler, F., Leitenstorfer, A., & Keller, U. (2007) · Optics Letters · doi:10.1364/ol.32.001138 · Cited by 208
Self-citationCavity-enhanced direct frequency comb spectroscopy
Thorpe, M. J., & Ye, J. (2008) · Applied Physics B · doi:10.1007/s00340-008-3019-1 · Cited by 167
Self-citationSun, J., Gale, B. J. S., & Reid, D. T. (2007) · Optics Letters · doi:10.1364/ol.32.001414 · Cited by 96
Mid-infrared optical combs from a compact amplified Er-doped fiber oscillator
Gambetta, A., Ramponi, R., & Marangoni, M. (2008) · Optics Letters · doi:10.1364/ol.33.002671 · Cited by 95
Flexible and rapidly configurable femtosecond pulse generation in the mid-IR
Foreman, S. M., Jones, D. J., & Ye, J. (2003) · Optics Letters · doi:10.1364/ol.28.000370 · Cited by 73
Self-citationMid-infrared fibre-based optical comb
Maddaloni, P., Malara, P., Gagliardi, G., & Natale, P. D. (2006) · New Journal of Physics · doi:10.1088/1367-2630/8/11/262 · Cited by 73
Thorpe, M. J., Adler, F., Cossel, K. C., de Miranda, M. H. G., & Ye, J. (2008) · Chemical Physics Letters · doi:10.1016/j.cplett.2008.11.064 · Cited by 49
Self-citationGebs, R., Dekorsy, T., Diddams, S. A., & Bartels, A. (2008) · Optics Express · doi:10.1364/oe.16.005397 · Cited by 29
Cited by
Schliesser, A., Picqué, N., & Hänsch, T. W. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.142 · Cited by 1,436
Fermann, M. E., & Hartl, I. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.280 · Cited by 1,160
Self-citationMid-infrared frequency comb based on a quantum cascade laser
Hugi, A., Villares, G., Blaser, S., Liu, H. C., & Faist, J. (2012) · Nature · doi:10.1038/nature11620 · Cited by 850
Optical frequency combs: Coherently uniting the electromagnetic spectrum
Diddams, S. A., Vahala, K., & Udem, T. (2020) · Science · doi:10.1126/science.aay3676 · Cited by 714
Broadband mid-infrared frequency comb generation in a Si_3N_4 microresonator
Luke, K., Okawachi, Y., Lamont, M. R. E., Gaeta, A. L., & Lipson, M. (2015) · Optics Letters · doi:10.1364/ol.40.004823 · Cited by 648
Metadata
- Authors
- Adler, F., Cossel, K. C., Thorpe, M. J., Hartl, I., Fermann, M. E., & Ye, J.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2009-04-20
- Volume
- 34
- Issue
- 9
- Pages
- 1330
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W1869297743
- Cited by
- 314
- References
- 16
- FWCI
- 16.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.